47,065 research outputs found
Colloidal carbon particles as a new label for rapid immunochemical test methods: quantitative computer image analysis of results
Colloidal carbon particles can serve as label in sol particle immunoassays. The universal applicability of these particles in qualitative and (semi)quantitative immunoassays has been demonstrated. Sol particle and/or dipstick immunoassays, not yet optimized in terms of sensitivity, are discussed.\ud
\ud
The colloidal label has been used successfully in a mouse immunoglobulin isotyping kit. Human serum albumin spotted onto nitrocellulose in a concentration range of 7.8 to 1000 ng could be detected using anti-albumin antibody adsorbed onto colloidal carbon particles. It was also possible to perform a competitive assay with this conjugate for a concentration range of free human serum albumin varying from 0.25 to 6.75 ¿g. The Kunitz-type trypsin inhibitor from soybean was determined by a colloidal carbon based immunoassay in a range of 2.5 to 160 ng. In this assay, free and colloidal carbon-bound inhibitor competed for binding specific antibodies spotted onto a nitrocellulose membrane.\ud
\ud
An image- and data-processing procedure has been developed that enables a rapid and simple quantification of colloidal carbon sol particle immunoassays. The average grey level of a spot is taken as a measure for quantitative purposes. This so-called Sol-particle Image Processed ImmunoAssay (SIPIA) procedure is equally well applicable to assays using other colloidal particles
Protein Ingredients Control in Gluten Free Products Using SDS-PAGE, Developed Competitive Enzyme Immunoassays and Commercial ELISA Kits.
Some protein ingredients declared in the label of gluten free products are allergenic proteins (milk, soy and egg).The proper identification of these proteins in food products is important for consumers who have food allergies. The aim of this study was to control the presence of protein ingredients declared in the label of gluten free products. Samples were analyzed with sodium dodecylsulfate polyacrylamide gel electrophoresis (SDS-PAGE), using an extractive solution of total proteins (Tris-ClH buffer 0.0625 M with 3% sodium dodecylsulfate and 2% 2-mercaptoethanol; pH: 6.8) and a selective solvent for the extraction of caseins (isopropanol 55° + 2-mercaptoethanol / ISO + ME). Developed Competitive enzyme immunoassays were used for the detection / quantification of milk, soy and egg proteins in products elaborated with rice flour. Specific polyclonal rabbit antiserums against milk, soy and egg proteins were used as primary antibodies in these competitive enzyme immunoassays. Commercial ELISA kits from Neogen, R-Biopharm and Romer were used to verify the results. In some samples undeclared allergens were detected. Correct allergens labeling is very important for the safety of allergic consumers. In conclusion, it is possible to identify all the proteins ingredients in these gluten-free foods studied, using a combination of electrophoretic methods and immunochemical methods.Fil: Cellerino, Karina. Universidad de Buenos Aires. Facultad de Farmacia y BioquÃmica; Argentina. Consejo Nacional de Investigaciones CientÃficas y Técnicas; ArgentinaFil: Cagnasso, Carolina Elisa. Universidad de Buenos Aires. Facultad de Farmacia y BioquÃmica; ArgentinaFil: Greco, Carola Beatriz. Universidad de Buenos Aires. Facultad de Farmacia y BioquÃmica; ArgentinaFil: Docena, Guillermo H.. Consejo Nacional de Investigaciones CientÃficas y Técnicas. Centro CientÃfico Tecnológico Conicet - La Plata. Instituto de Estudios Inmunológicos y Fisiopatológicos. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Instituto de Estudios Inmunológicos y Fisiopatológicos; ArgentinaFil: Polenta, Gustavo Alberto. Instituto Nacional de TecnologÃa Agropecuaria; Argentina. Consejo Nacional de Investigaciones CientÃficas y Técnicas; ArgentinaFil: Ferreyra, Marcela Verónica. Instituto Nacional de TecnologÃa Industrial; ArgentinaFil: Lopez, Laura Beatriz. Universidad de Buenos Aires. Facultad de Farmacia y BioquÃmica; Argentina. Consejo Nacional de Investigaciones CientÃficas y Técnicas; Argentin
Recommended from our members
Optimal designs for asymmetric sigmoidal response curves in bioassays and immunoassays
Recent studies show that asymmetric sigmoidal response curves are not uncommonin biomedical studies. For example, the 5-parameter logistic (5PL) model isfrequently used to model and analyze responses from bioassays and immunoassayswhich can be skewed. Various types of optimal experimental designs for 2, 3 and4-parameter logistic models have been reported but not for the more complicated5-parameter logistic (5PL) model. Designs currently used for the 5PL model seemad-hoc with no formal quantitative assessment of their efficiencies. We constructdifferent types of optimal designs for studying various features of the 5PL modeland use them to evaluate efficiencies of commonly used designs in bioassays andimmunoassays. We also create a user-friendly software package to search for optimaldesigns tailor-made to user-specified problems for the 5PL model and evaluaterobustness properties of the design under a variation of criteria, model formsand mis-specification in the nominal values of the model parameters. Our designstrategies can also account for several objectives with varying degrees of importance.As an application, we generate optimal designs for the 5PL model for real studiesin immunoassays and bioassays, and show currently used designs are generallyinefficient for statistical inference
Harmonization of growth hormone measurements with different immunoassays by data adjustment
Background: The aim of our study was to evaluate the between-assay variability of commercially available immunoassays for the measurement of human growth hormone (hGH). In addition, we asked whether the comparability of the diagnosis of childhood onset growth hormone deficiency could be improved by adjusting hGH results by statistical methods, such as linear regression, conversion factors, and quantile transformation. Methods: In archived sera from 312 children and adolescents (age: 17 days-17 years) hGH values between 0.01 and 16.5 ng/mL were determined by using the following immunoassays: AutoDELFIA (PerkinElmer), BC-IRMA (Beckman-Coulter), ELISA (Mediagnost), IMMULITE 2000 (Siemens), iSYS (IDS), Liaison (DiaSorin), UniCel DxI 800 Access (BeckmanCoulter) and "In house"-RIA (Tubingen). Results: The assays differed in median hGH concentrations by as much as 5.44 ng/mL (Immulite), and as little as 2.67 ng/mL (BC-IRMA). The mean difference between assays ranged from 0.35 to 2.71 ng/mL, whereas several samples displayed differences up to 11.4 ng/mL. The best correlation (r=0.992) was found between AutoDELFIA and Liasion, the lowest (r=0.864) was between an in-house RIA and iSYS. The between-assay CV (mean +/- SD) of values within the cut-off range was 24.3%+/- 7.4%, resulting in an assay-dependent diagnosis of growth hormone deficiency (GHD) in more than 27% of patients. Yet, adjustment of this data by linear regression or a conversion factor reduced the CV below 14%, and the ratio of assay-dependent diagnoses below 8%. Using quantile transformation, the CV and ratio were reduced to 11.4% and < 1%, respectively. Conclusions: hGH measurements using different assays vary significantly. Linear regression, conversion factors, or particularly quantile transformation are useful tools to improve comparability in the diagnostic procedure for the confirmation of GHD in childhood and adolescence
Fully integrated digital microfluidics platform for automated immunoassay; a versatile tool for rapid, specific detection of a wide range of pathogens
© 2018 Elsevier Ltd. All rights reserved. This manuscript is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International Licence http://creativecommons.org/licenses/by-nc-nd/4.0/.With the tangible threat posed by the release of chemical and biological warfare (CBW) agents, detection of airborne pathogens is a critical military and security concern. Recent air sampling techniques developed for biocollection take advantage of Electrowetting on Dielectric (EWOD) to recover material, producing highly concentrated droplet samples. Bespoke EWOD-based digital microfluidics platforms are very well suited to take full advantage of the microlitre concentrated droplet resulting from this recovery process. In this paper we present a free-standing, fully automated DMF platform for immunoassay. Using this system, we demonstrate the automated detection of four classes of CBW agent simulant biomolecules and organisms each representing credible threat agents. Taking advantage of the full magnetic separation process with antibody-bound microbeads, rapid and complete separation of specific target antigen can be achieved with minimal washing steps allowing for very rapid detection. Here, we report clear detection of four categories of antigens achieved with assay completion times of between six and ten minutes. Detection of HSA, Bacillus atrophaeus (BG spores), MS2 bacteriophage and Escherichia coli are demonstrated with estimated limit of detection of respectively 30 ng ml -1, 4 × 10 4 cfu ml -1, 10 6 pfu ml -1 and 2 × 10 7 cfu ml -1. The fully-integrated portable platform described in this paper is highly compatible with the next generation of electrowetting-coupled air samplers and thus shows strong potential toward future in-field deployable biodetection systems and could have key implication in life-changing sectors such as healthcare, environment or food security.Peer reviewe
Recommended from our members
A simple device for multiplex ELISA made from melt-extruded plastic microcapillary film
We present a simple device for multiplex quantitative enzyme-linked immunosorbant assays (ELISA) made from a novel melt-extruded microcapillary film (MCF) containing a parallel array of 200µm capillaries along its length. To make ELISA devices different protein antigens or antibodies were immobilised inside individual microcapillaries within long reels of MCF extruded from fluorinated ethylene propylene (FEP). Short pieces of coated film were cut and interfaced with a pipette, allowing sequential uptake of samples and detection solutions into all capillaries from a reagent well. As well as being simple to produce, these FEP MCF devices have excellent light transmittance allowing direct optical interrogation of the capillaries for simple signal quantification. Proof of concept experiments demonstrate both quantitative and multiplex assays in FEP MCF devices using a standard direct ELISA procedure and read using a flatbed scanner. This new multiplex immunoassay platform should find applications ranging from lab detection to point-of-care and field diagnostics
Biological and technical variables affecting immunoassay recovery of cytokines from human serum and simulated vaginal fluid: A multicenter study
The increase of proinflammatory cytokines in vaginal secretions may serve as a surrogate marker of unwanted inflammatory reaction to microbicide products topically applied for the prevention of sexually transmitted diseases, including HIV-1. Interleukin (IL)-1β and IL-6 have been proposed as indicators of inflammation and increased risk of HIV-1 transmission; however, the lack of information regarding detection platforms optimal for vaginal fluids and interlaboratory variation limit their use for microbicide evaluation and other clinical applications. This study examines fluid matrix variants relevant to vaginal sampling techniques and proposes a model for interlaboratory comparisons across current cytokine detection technologies. IL-1β and IL-6 standards were measured by 12 laboratories in four countries, using 14 immunoassays and four detection platforms based on absorbance, chemiluminescence, electrochemiluminescence, and fluorescence. International reference preparations of cytokines with defined biological activity were spiked into (1) a defined medium simulating the composition of human vaginal fluid at pH 4.5 and 7.2, (2) physiologic salt solutions (phosphate-buffered saline and saline) commonly used for vaginal lavage sampling in clinical studies of cytokines, and (3) human blood serum. Assays were assessed for reproducibility, linearity, accuracy, and significantly detectable fold difference in cytokine level. Factors with significant impact on cytokine recovery were determined by Kruskal−Wallis analysis of variance with Dunn’s multiple comparison test and multiple regression models. All assays showed acceptable intra-assay reproducibility; however, most were associated with significant interlaboratory variation. The smallest reliably detectable cytokine differences (P < 0.05) derived from pooled interlaboratory data varied from 1.5- to 26-fold depending on assay, cytokine, and matrix type. IL-6 but not IL-1β determinations were lower in both saline and phosphate-buffered saline as compared to vaginal fluid matrix, with no significant effect of pH. The (electro)chemiluminescence-based assays were most discriminative and consistently detected <2-fold differences within each matrix type. The Luminex-based assays were less discriminative with lower reproducibility between laboratories. These results suggest the need for uniform vaginal sampling techniques and a better understanding of immunoassay platform differences and cross-validation before the biological significance of cytokine variations can be validated in clinical trials. This investigation provides the first standardized analytic approach for assessing differences in mucosal cytokine levels and may improve strategies for monitoring immune responses at the vaginal mucosal interface
Magnetic particle plug-based assays for biomarker analysis
Conventional immunoassays offer selective and quantitative detection of a number of biomarkers, but are laborious and time-consuming. Magnetic particle-based assays allow easy and rapid selection of analytes, but still suffer from the requirement of tedious multiple reaction and washing steps. Here, we demonstrate the trapping of functionalised magnetic particles within a microchannel for performing rapid immunoassays by flushing consecutive reagent and washing solutions over the trapped particle plug. Three main studies were performed to investigate the potential of the platform for quantitative analysis of biomarkers: (i) a streptavidin-biotin binding assay; (ii) a sandwich assay of the inflammation biomarker, C-reactive protein (CRP); and (iii) detection of the steroid hormone, progesterone (P4), towards a competitive assay. Quantitative analysis with low limits of detection was demonstrated with streptavidin-biotin, while the CRP and P4 assays exhibited the ability to detect clinically relevant analytes, and all assays were completed in only 15 min. These preliminary results show the great potential of the platform for performing rapid, low volume magnetic particle plug-based assays of a range of clinical biomarkers via an exceedingly simple technique
Recommended from our members
Multiplexed in-gel microfluidic immunoassays: characterizing protein target loss during reprobing of benzophenone-modified hydrogels.
From whole tissues to single-cell lysate, heterogeneous immunoassays are widely utilized for analysis of protein targets in complex biospecimens. Recently, benzophenone-functionalized hydrogel scaffolds have been used to immobilize target protein for immunoassay detection with fluorescent antibody probes. In benzophenone-functionalized hydrogels, multiplex target detection occurs via serial rounds of chemical stripping (incubation with sodium-dodecyl-sulfate (SDS) and β-mercaptoethanol at 50-60 °C for ≥1 h), followed by reprobing (interrogation with additional antibody probes). Although benzophenone facilitates covalent immobilization of proteins to the hydrogel, we observe 50% immunoassay signal loss of immobilized protein targets during stripping rounds. Here, we identify and characterize signal loss mechanisms during stripping and reprobing. We posit that loss of immobilized target is responsible for ≥50% of immunoassay signal loss, and that target loss is attributable to disruption of protein immobilization by denaturing detergents (SDS) and incubation at elevated temperatures. Furthermore, our study suggests that protein losses under non-denaturing conditions are more sensitive to protein structure (i.e., hydrodynamic radius), than to molecular mass (size). We formulate design guidance for multiplexed in-gel immunoassays, including that low-abundance proteins be immunoprobed first, even when targets are covalently immobilized to the gel. We also recommend careful scrutiny of the order of proteins targets detected via multiple immunoprobing cycles, based on the protein immobilization buffer composition
SpotNet - Learned iterations for cell detection in image-based immunoassays
Accurate cell detection and counting in the image-based ELISpot and
FluoroSpot immunoassays is a challenging task. Recently proposed methodology
matches human accuracy by leveraging knowledge of the underlying physical
process of these assays and using proximal optimization methods to solve an
inverse problem. Nonetheless, thousands of computationally expensive iterations
are often needed to reach a near-optimal solution. In this paper, we exploit
the structure of the iterations to design a parameterized computation graph,
SpotNet, that learns the patterns embedded within several training images and
their respective cell information. Further, we compare SpotNet to a
convolutional neural network layout customized for cell detection. We show
empirical evidence that, while both designs obtain a detection performance on
synthetic data far beyond that of a human expert, SpotNet is easier to train
and obtains better estimates of particle secretion for each cell.Comment: 5 pages, 4 figures, 2019 IEEE 16th International Symposium on
Biomedical Imaging (ISBI 2019), Venice, Italy, April 8-11, 201
- …