1,117 research outputs found

    Design and performance of a compact and stationary microSPECT system

    Get PDF
    Purpose: Over the last ten years, there has been an extensive growth in the development of microSPECT imagers. Most of the systems are based on the combination of conventional, relatively large gamma cameras with poor intrinsic spatial resolution and multipinhole collimators working in large magnification mode. Spatial resolutions range from 0.58 to 0.76 mm while peak sensitivities vary from 0.06% to 0.4%. While pushing the limits of performance is of major importance, the authors believe that there is a need for smaller and less complex systems that bring along a reduced cost. While low footprint and low-cost systems can make microSPECT available to more researchers, the ease of operation and calibration and low maintenance cost are additional factors that can facilitate the use of microSPECT in molecular imaging. In this paper, the authors simulate the performance of a microSPECT imager that combines high space-bandwidth detectors and pinholes with truncated projection, resulting in a small and stationary system. Methods: A system optimization algorithm is used to determine the optimal SPECT systems, given our high resolutions detectors and a fixed field-of-view. These optimal system geometries are then used to simulate a Defrise disk phantom and a hot rod phantom. Finally, a MOBY mouse phantom, with realistic concentrations of Tc99m-tetrofosmin is simulated. Results: Results show that the authors can successfully reconstruct a Defrise disk phantom of 24 mm in diameter without any rotating system components or translation of the object. Reconstructed spatial resolution is approximately 800 mu m while the peak sensitivity is 0.23%. Finally, the simulation of the MOBY mouse phantom shows that the authors can accurately reconstruct mouse images. Conclusions: These results show that pinholes with truncated projections can be used in small magnification or minification mode to obtain a compact and stationary microSPECT system. The authors showed that they can reach state-of-the-art system performance and can successfully reconstruct images with realistic noise levels in a preclinical context. Such a system can be useful for dynamic SPECT imaging. 2013 American Association of Physicists in Medicine

    Distribution and dynamics of Tc-99m-pertechnetate uptake in the thyroid and other organs assessed by single-photon emission computed tomography in living mice

    Get PDF
    Background: Tc-99m pertechnetate is a well-known anion, used for clinical imaging of thyroid function. This gamma emitter is transported by the sodium iodide symporter but is not incorporated into thyroglobulin. Scintigraphy using Tc-99m pertechnetate or 123 iodide represents a powerful tool for the study of sodium iodide symporter activity in different organs of living animal models. However, in many studies that have been performed in mice, the thyroid could not be distinguished from the salivary glands. In this work, we have evaluated the use of a clinically dedicated single-photon emission computed tomography (SPECT) camera for thyroid imaging and assessed what improvements are necessary for the development of this technique. Methods: SPECT of the mouse neck region, with pinhole collimation and geometric calibration, was used for the individual measurement of Tc-99m pertechnetate uptake in the thyroid and the salivary glands. Uptake in the stomach was studied by planar whole-body imaging. Uptake kinetics and biodistribution studies were performed by sequential imaging. Results: This work has shown that thyroid imaging in living mice can be performed with a SPECT camera originally built for clinical use. Our experiments indicate that Tc-99m pertechnetate uptake is faster in the thyroid than in the salivary glands and the stomach. The decrease in Tc-99m pertechnetate uptake after injection of iodide or perchlorate as competitive inhibitors was also studied. The resulting rate decreases were faster in the thyroid than in the salivary glands or the stomach. Conclusions: We have shown that a clinically dedicated SPECT camera can be used for thyroid imaging. In our experiments, SPECT imaging allowed the analysis of Tc-99m pertechnetate accumulation in individual organs and revealed differences in uptake kinetics

    The Performance of MLEM for Dynamic Imaging From Simulated Few-View, Multi-Pinhole SPECT

    Get PDF
    Stationary small-animal SPECT systems are being developed for rapid dynamic imaging from limited angular views. This work quantified, through simulations, the performance of Maximum Likelihood Expectation Maximization (MLEM) for reconstructing a time-activity curve (TAC) with uptake duration of a few seconds from a stationary, three-camera multi-pinhole SPECT system. The study also quantified the benefits of a heuristic method of initializing the reconstruction with a prior image reconstructed from a conventional number of views, for example from data acquired during the late-study portion of the dynamic TAC. We refer to MLEM reconstruction initialized by a prior-image initial guess (IG) as MLEMig. The effect of the prior-image initial guess on the depiction of contrast between two regions of a static phantom was quantified over a range of angular sampling schemes. A TAC was modeled from the experimentally measured uptake of 99mTc-hexamethylpropyleneamine oxime (HMPAO) in the rat lung. The resulting time series of simulated images was quantitatively analyzed with respect to the accuracy of the estimated exponential washin and washout parameters. In both static and dynamic phantom studies, the prior-image initial guess improved the spatial depiction of the phantom, for example improved definition of the cylinder boundaries and more accurate quantification of relative contrast between cylinders. For example in the dynamic study, there was ~ 50% error in relative contrast for MLEM reconstructions compared to ~ 25-30% error for MLEMig. In the static phantom study, the benefits of the initial guess decreased as the number of views increased. The prior-image initial guess introduced an additive offset in the reconstructed dynamic images, likely due to biases introduced by the prior image. MLEM initialized with a uniform initial guess yielded images that faithfully reproduced the time dependence of the simulated TAC; there were no s- atistically significant differences in the mean exponential washin/washout parameters estimated from MLEM reconstructions compared to the true values. Washout parameters estimated from MLEMig reconstructions did not differ significantly from the true values, however the estimated washin parameter differed significantly from the true value in some cases. Overall, MLEM reconstruction from few views and a uniform initial guess accurately quantified the time dependance of the TAC while introducing errors in the spatial depiction of the object. Initializing the reconstruction with a late-study initial guess improved spatial accuracy while decreasing temporal accuracy in some cases

    Analytical Modelling and Simulation of Single and Double Cone Pinholes for Real-Time In-Body Tracking of an HDR Brachytherapy Source

    Full text link
    © 2016 IEEE. The choice of pinhole geometry is a critical factor in the performance of pinhole-collimator-based source tracking systems for brachytherapy QA. In this work, an analytical model describing the penetrative sensitivity of a single-cone pinhole collimator to photons emitted from a point source is derived. Using existing models for single-cone resolution and double-cone sensitivity and resolution, the theoretical sensitivity and resolution of the single-cone collimator are quantitatively compared with those of a double-cone collimator with an equivalent field of view. Monte Carlo simulations of the single and double-cone pinhole collimators using an accurate 3D model of a commercial high dose rate brachytherapy source are performed to evaluate the relative performance of each geometry for a novel real-time HDR brachytherapy QA system, HDR BrachyView. The theoretical penetrative sensitivity of the single-cone pinhole is shown to be higher than the double-cone pinhole, which is in agreement with the results from the Monte Carlo simulations. The wider pinhole response function of the single-cone collimator results in a larger total error between the projected center of the source and the estimated center of mass of the source projection for the single-cone collimator, with the greatest error (at the maximum FoV angle) being 0.54 mm for the double-cone pinhole and 1.37 mm for the single-cone at θ = 60°. The double-cone pinhole geometry is determined to be the most appropriate choice for the pinhole collimator in the HDR BrachyView probe

    SPECT Imaging of Pulmonary Blood Flow in a Rat

    Get PDF
    Small animal imaging is experiencing rapid development due to its importance in providing high-throughput phenotypic data for functional genomics studies. We have developed a single photon emission computed tomography (SPECT) system to image the pulmonary perfusion distribution in the rat. A standard gamma camera, equipped with a pinhole collimator, was used to acquire SPECT projection images at 40 sec/view of the rat thorax following injection of Tc99m labeled albumin that accumulated in the rat\u27s lungs. A voxel-driven, ordered-subset expectation maximization reconstruction was implemented. Following SPECT imaging, the rat was imaged using micro-CT with Feldkamp conebeam reconstruction. The two reconstructed image volumes were fused to provide a structure/function image of the rat thorax. Reconstruction accuracy and performance were evaluated using numerical simulations and actual imaging of an experimental phantom consisting of Tc99m filled chambers with known diameters and count rates. Full-width half-maximum diameter measurement errors decreased with increasing chamber diameter, ranging from \u3c 6% down to 0.1%. Errors in the ratio of count rate estimates between tubes were also diameter dependent but still relatively small. This preliminary study suggests that SPECT will be useful for imaging and quantifying the pulmonary blood flow distribution and the distribution of Tc99m labeled ligands in the lungs of small laboratory animals

    Preclinical SPECT imaging based on compact collimators and high resolution scintillation detectors

    Get PDF

    Doctor of Philosophy

    Get PDF
    dissertationSingle Photon Emission Computed Tomography (SPECT) myocardial perfusion imaging (MPI), a noninvasive and effective method for diagnosing coronary artery disease (CAD), is the most commonly performed SPECT procedure. Hence, it is not surprising that there is a tremendous market need for dedicated cardiac SPECT scanners. In this dissertation, a novel dedicated stationary cardiac SPECT system that using a segmented-parallel-hole collimator is investigated in detail. This stationary SPECT system can acquire true dynamic SPECT images and is inexpensive to build. A segmented-parallel-hole collimator was designed to fit the existing general-purpose SPECT cameras without any mechanical modifications of the scanner while providing higher detection sensitivity. With a segmented-parallel-hole collimator, each detector was segmented to seven sub-detector regions, providing seven projections simultaneously. Fourteen view-angles over 180 degree were obtained in total with two detectors positioned at 90 degree apart. The whole system was able to provide an approximate 34-fold gain in sensitivity over the conventional single-head SPECT system. The potential drawbacks of the stationary cardiac SPECT system are data truncation from small field of view (FOV) and limited number of view angles. A tailored maximum-likelihood expectation-maximization (ML-EM) algorithm was derived for reconstruction of truncated projections with few view angles. The artifacts caused by truncation and insufficient number of views were suppressed by reducing the image updating step sizes of the pixels outside the FOV. The performance of the tailored ML-EM algorithm was verified by computer simulations and phantom experiments. Compared with the conventional ML-EM algorithm, the tailored ML-EM algorithm successfully suppresses the streak artifacts outside the FOV and reduces the distortion inside the FOV. At 10 views, the tailored ML-EM algorithm has a much lower mean squared error (MSE) and higher relative contrast. In addition, special attention was given to handle the zero-valued projections in the image reconstruction. There are two categories of zero values in the projection data: one is outside the boundary of the object and the other is inside the object region, which is caused by count starvation. A positive weighting factor c was introduced to the ML-EM algorithm. By setting c>1 for zero values outside the projection, the boundary in the image is well preserved even at extremely low iterations. The black lines, caused by the zero values inside the object region, are completely removed by setting 0< c<1. Finally, the segmented-parallel-hole collimator was fabricated and calibrated using a point source. Closed-form explicit expressions for the slant angles and rotation radius were derived from the proposed system geometry. The geometric parameters were estimated independently or jointly. Monte Carlo simulations and real emission data were used to evaluate the proposed calibration method and the stationary cardiac system. The simulation results show that the difference between the estimated and the actual value is less than 0.1 degree for the slant angles and the 5 mm for the rotation radius, which is well below the detector's intrinsic resolution

    Modeling and evaluation of new collimator geometries in SPECT

    Get PDF

    ALBIRA: A small animal PET/SPECT/CT imaging system

    Full text link
    Purpose: The authors have developed a trimodal PET/SPECT/CT scanner for small animal imaging. The gamma ray subsystems are based on monolithic crystals coupled to multianode photomultiplier tubes (MA-PMTs), while computed tomography (CT) comprises a commercially available microfocus x-ray tube and a CsI scintillator 2D pixelated flat panel x-ray detector. In this study the authors will report on the design and performance evaluation of the multimodal system. Methods: X-ray transmission measurements are performed based on cone-beam geometry. Individual projections were acquired by rotating the x-ray tube and the 2D flat panel detector, thus making possible a transaxial field of view (FOV) of roughly 80 mm in diameter and an axial FOV of 65 mm for the CT system. The single photon emission computed tomography (SPECT) component has a dual head detector geometry mounted on a rotating gantry. The distance between the SPECT module detectors can be varied in order to optimize specific user requirements, including variable FOV. The positron emission tomography (PET) system is made up of eight compact modules forming an octagon with an axial FOV of 40 mm and a transaxial FOV of 80 mm in diameter. The main CT image quality parameters (spatial resolution and uniformity) have been determined. In the case of the SPECT, the tomographic spatial resolution and system sensitivity have been evaluated with a99mTc solution using single-pinhole and multi-pinhole collimators. PET and SPECT images were reconstructed using three-dimensional (3D) maximum likelihood and ordered subset expectation maximization (MLEM and OSEM) algorithms developed by the authors, whereas the CT images were obtained using a 3D based FBP algorithm. Results: CT spatial resolution was 85μm while a uniformity of 2.7% was obtained for a water filled phantom at 45 kV. The SPECT spatial resolution was better than 0.8 mm measured with a Derenzo-like phantom for a FOV of 20 mm using a 1-mm pinhole aperture collimator. The full width at half-maximum PET radial spatial resolution at the center of the field of view was 1.55 mm. The SPECT system sensitivity for a FOV of 20 mm and 15% energy window was 700 cps/MBq (7.8 × 10−2%) using a multi-pinhole equipped with five apertures 1 mm in diameter, whereas the PET absolute sensitivity was 2% for a 350–650 keV energy window and a 5 ns timing window. Several animal images are also presented. Conclusions: The new small animal PET/SPECT/CT proposed here exhibits high performance, producing high-quality images suitable for studies with small animals. Monolithic design for PET and SPECT scintillator crystals reduces cost and complexity without significant performance degradation.This study was supported by the Spanish Plan Nacional de Investigacion Cientifica, Desarrollo e Innovacion Tecnologica (I+D+I) under Grant No. FIS2010-21216-CO2-01 and Valencian Local Government under Grant PROMETEO 2008/114. The authors also thank Brennan Holt for checking and correcting the text.Sánchez Martínez, F.; Orero Palomares, A.; Soriano Asensi, A.; Correcher Salvador, C.; Conde Castellanos, PE.; González Martínez, AJ.; Hernández Hernández, L.... (2013). ALBIRA: A small animal PET/SPECT/CT imaging system. Medical Physics. 40(5):5190601-5190611. https://doi.org/10.1118/1.4800798S5190601519061140

    SPECT imaging with rotating slat collimator

    Get PDF
    • …
    corecore