152 research outputs found

    Doctor of Philosophy

    Get PDF
    dissertationSince the late 1950s, scientists have been working toward realizing implantable devices that would directly monitor or even control the human body's internal activities. Sophisticated microsystems are used to improve our understanding of internal biological processes in animals and humans. The diversity of biomedical research dictates that microsystems must be developed and customized specifically for each new application. For advanced long-term experiments, a custom designed system-on-chip (SoC) is usually necessary to meet desired specifications. Custom SoCs, however, are often prohibitively expensive, preventing many new ideas from being explored. In this work, we have identified a set of sensors that are frequently used in biomedical research and developed a single-chip integrated microsystem that offers the most commonly used sensor interfaces, high computational power, and which requires minimum external components to operate. Included peripherals can also drive chemical reactions by setting the appropriate voltages or currents across electrodes. The SoC is highly modular and well suited for prototyping in and ex vivo experimental devices. The system runs from a primary or secondary battery that can be recharged via two inductively coupled coils. The SoC includes a 16-bit microprocessor with 32 kB of on chip SRAM. The digital core consumes 350 μW at 10 MHz and is capable of running at frequencies up to 200 MHz. The integrated microsystem has been fabricated in a 65 nm CMOS technology and the silicon has been fully tested. Integrated peripherals include two sigma-delta analog-to-digital converters, two 10-bit digital-to-analog converters, and a sleep mode timer. The system also includes a wireless ultra-wideband (UWB) transmitter. The fullydigital transmitter implementation occupies 68 x 68 μm2 of silicon area, consumes 0.72 μW static power, and achieves an energy efficiency of 19 pJ/pulse at 200 MHz pulse repetition frequency. An investigation of the suitability of the UWB technology for neural recording systems is also presented. Experimental data capturing the UWB signal transmission through an animal head are presented and a statistical model for large-scale signal fading is developed

    Recent Advances in Neural Recording Microsystems

    Get PDF
    The accelerating pace of research in neuroscience has created a considerable demand for neural interfacing microsystems capable of monitoring the activity of large groups of neurons. These emerging tools have revealed a tremendous potential for the advancement of knowledge in brain research and for the development of useful clinical applications. They can extract the relevant control signals directly from the brain enabling individuals with severe disabilities to communicate their intentions to other devices, like computers or various prostheses. Such microsystems are self-contained devices composed of a neural probe attached with an integrated circuit for extracting neural signals from multiple channels, and transferring the data outside the body. The greatest challenge facing development of such emerging devices into viable clinical systems involves addressing their small form factor and low-power consumption constraints, while providing superior resolution. In this paper, we survey the recent progress in the design and the implementation of multi-channel neural recording Microsystems, with particular emphasis on the design of recording and telemetry electronics. An overview of the numerous neural signal modalities is given and the existing microsystem topologies are covered. We present energy-efficient sensory circuits to retrieve weak signals from neural probes and we compare them. We cover data management and smart power scheduling approaches, and we review advances in low-power telemetry. Finally, we conclude by summarizing the remaining challenges and by highlighting the emerging trends in the field

    Modulation Techniques for Biomedical Implanted Devices and Their Challenges

    Get PDF
    Implanted medical devices are very important electronic devices because of their usefulness in monitoring and diagnosis, safety and comfort for patients. Since 1950s, remarkable efforts have been undertaken for the development of bio-medical implanted and wireless telemetry bio-devices. Issues such as design of suitable modulation methods, use of power and monitoring devices, transfer energy from external to internal parts with high efficiency and high data rates and low power consumption all play an important role in the development of implantable devices. This paper provides a comprehensive survey on various modulation and demodulation techniques such as amplitude shift keying (ASK), frequency shift keying (FSK) and phase shift keying (PSK) of the existing wireless implanted devices. The details of specifications, including carrier frequency, CMOS size, data rate, power consumption and supply, chip area and application of the various modulation schemes of the implanted devices are investigated and summarized in the tables along with the corresponding key references. Current challenges and problems of the typical modulation applications of these technologies are illustrated with a brief suggestions and discussion for the progress of implanted device research in the future. It is observed that the prime requisites for the good quality of the implanted devices and their reliability are the energy transformation, data rate, CMOS size, power consumption and operation frequency. This review will hopefully lead to increasing efforts towards the development of low powered, high efficient, high data rate and reliable implanted devices

    Implantable Biomedical Devices

    Get PDF

    Micropower circuits for bidirectional wireless telemetry in neural recording applications

    Get PDF
    Journal ArticleState-of-the art neural recording systems require electronics allowing for transcutaneous, bidirectional data transfer. As these circuits will be implanted near the brain, they must be small and low power. We have developed micropower integrated circuits for recovering clock and data signals over a transcutaneous power link. The data recovery circuit produces a digital data signal from an ac power waveform that has been amplitude modulated. We have also developed an FM transmitter with the lowest power dissipation reported for biosignal telemetry. The FM transmitter consists of a low-noise biopotential amplifier and a voltage controlled oscillator used to transmit amplified neural signals at a frequency near 433 MHz. All circuits were fabricated in a standard 0.5- m CMOS VLSI process. The resulting chip is powered through a wireless inductive link. The power consumption of the clock and data recovery circuits is measured to be 129 W; the power consumption of the transmitter is measured to be 465 W when using an external surface mount inductor. Using a parasitic antenna less than 2 mm long, a received power level was measured to be 59 73 dBmat a distance of one meter

    Wireless neural recording with single low-power integrated circuit

    Get PDF
    Journal ArticleWe present benchtop and in vivo experimental results from an integrated circuit designed for wireless implantable neural recording applications. The chip, which was fabricated in a commercially available 0.6- m 2P3M BiCMOS process, contains 100 amplifiers, a 10-bit analog-to-digital converter (ADC), 100 threshold-based spike detectors, and a 902-928 MHz frequency-shift-keying (FSK) transmitter. Neural signals from a selected amplifier are sampled by the ADC at 15.7 kSps and telemetered over the FSK wireless data link. Power, clock, and command signals are sent to the chip wirelessly over a 2.765-MHz inductive (coil-to-coil) link. The chip is capable of operating with only two off-chip components: a power/command receiving coil and a 100-nF capacitor

    Wireless Telemetry for Implantable Biomedical Microsystems

    Get PDF

    A wireless implantable multichannel digital neural recording system for a micromachined sieve electrode

    Get PDF
    This paper reports the development of an implantable, fully integrated, multichannel peripheral neural recording system, which is powered and controlled using an RF telemetry link, The system allows recording of +/-500 mu V neural signals from axons regenerated through a micromachined silicon sieve electrode, These signals are amplified using on-chip 100 Hz to 3.1 kHz bandlimited amplifiers, multiplexed, and digitized with a low-power (<2 mW), moderate speed (8 mu s/b) current-mode 8-b analog-to-digital converter (ADC), The digitized signal is transmitted to the outside world using a passive RF telemetry link, The circuit is implemented using a bipolar CMOS process, The signal processing CMOS circuitry dissipates only 10 mW of power from a 5-V supply while operating at 2 MHz and consumes 4 x 4 mm(2) of area, The overall circuit including the RF interface circuitry contains over 5000 transistors, dissipates 90 mW of power, and consumes 4 x 6 mm(2) of area

    Doctor of Philosophy

    Get PDF
    dissertationThis thesis presents the design, fabrication and characterization of a microelectromechanical system (MEMS) based complete wireless microsystem for brain interfacing, with very high quality factor and low power consumption. Components of the neuron sensing system include TiW fixed-fixed bridge resonator, MEMS oscillator based action-potential-to-RF module, and high-efficiency RF coil link for power and data transmissions. First, TiW fixed-fixed bridge resonator on glass substrate was fabricated and characterized, with resonance frequency of 100 - 500 kHz, and a quality factor up to 2,000 inside 10 mT vacuum. The effect of surface conditions on resonator's quality factor was studied with 10s of nm Al2O3 layer deposition with ALD (atomic layer deposition). It was found that MEMS resonator's quality factor decreased with increasing surface roughness. Second, action-potential-to-RF module was realized with MEMS oscillator based on TiW bridge resonator. Oscillation signal with frequency of 442 kHz and phase noise of -84.75 dBc/Hz at 1 kHz offset was obtained. DC biasing of the MEMS oscillator was modulated with neural signal so that the output RF waveform carries the neural signal information. Third, high-efficiency RF coil link for power and data communications was designed and realized. Based on the coupled mode theory (CMT), intermediate resonance coil was introduced and increased voltage transfer efficiency by up to 5 times. Finally, a complete neural interfacing system was demonstrated with board-level integration. The system consists of both internal and external systems, with wireless powering, wireless data transfer, artificial neuron signal generation, neural signal modulation and demodulation, and computer interface displaying restored neuron signal
    • …
    corecore