164 research outputs found

    A Fine Structure Stimulation Strategy and Related Concepts

    Get PDF

    In-vitro characterization of a cochlear implant system for recording of evoked compound action potentials

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Modern cochlear implants have integrated recording systems for measuring electrically evoked compound action potentials of the auditory nerve. The characterization of such recording systems is important for establishing a reliable basis for the interpretation of signals acquired in vivo. In this study we investigated the characteristics of the recording system integrated into the MED-EL PULSARCI<sup>100 </sup>cochlear implant, especially its linearity and resolution, in order to develop a mathematical model describing the recording system.</p> <p>Methods</p> <p>In-vitro setup: The cochlear implant, including all attached electrodes, was fixed in a tank of physiologic saline solution. Sinusoidal signals of the same frequency but with different amplitudes were delivered via a signal generator for measuring and recording on a single electrode.</p> <p>Computer simulations: A basic mathematical model including the main elements of the recording system, i.e. amplification and digitalization stage, was developed. For this, digital output for sinusoidal input signals of different amplitudes were calculated using in-vitro recordings as reference.</p> <p>Results</p> <p>Using an averaging of 100 measurements the recording system behaved linearly down to approximately -60 dB of the input signal range. Using the same method, a system resolution of 10 μV was determined for sinusoidal signals. The simulation results were in very good agreement with the results obtained from in-vitro experiments.</p> <p>Conclusions</p> <p>The recording system implemented in the MED-EL PULSARCI<sup>100 </sup>cochlear implant for measuring the evoked compound action potential of the auditory nerve operates reliably. The developed mathematical model provides a good approximation of the recording system.</p

    Site of cochlear stimulation and its effect on electrically evoked compound action potentials using the MED-EL standard electrode array

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The standard electrode array for the MED-EL MAESTRO cochlear implant system is 31 mm in length which allows an insertion angle of approximately 720°. When fully inserted, this long electrode array is capable of stimulating the most apical region of the cochlea. No investigation has explored Electrically Evoked Compound Action Potential (ECAP) recordings in this region with a large number of subjects using a commercially available cochlear implant system. The aim of this study is to determine if certain properties of ECAP recordings vary, depending on the stimulation site in the cochlea.</p> <p>Methods</p> <p>Recordings of auditory nerve responses were conducted in 67 subjects to demonstrate the feasibility of ECAP recordings using the Auditory Nerve Response Telemetry (ART™) feature of the MED-EL MAESTRO system software. These recordings were then analyzed based on the site of cochlear stimulation defined as basal, middle and apical to determine if the amplitude, threshold and slope of the amplitude growth function and the refractory time differs depending on the region of stimulation.</p> <p>Results</p> <p>Findings show significant differences in the ECAP recordings depending on the stimulation site. Comparing the apical with the basal region, on average higher amplitudes, lower thresholds and steeper slopes of the amplitude growth function have been observed. The refractory time shows an overall dependence on cochlear region; however post-hoc tests showed no significant effect between individual regions.</p> <p>Conclusions</p> <p>Obtaining ECAP recordings is also possible in the most apical region of the cochlea. However, differences can be observed depending on the region of the cochlea stimulated. Specifically, significant higher ECAP amplitude, lower thresholds and steeper amplitude growth function slopes have been observed in the apical region. These differences could be explained by the location of the stimulating electrode with respect to the neural tissue in the cochlea, a higher density, or an increased neural survival rate of neural tissue in the apex.</p> <p>Trial registration</p> <p>The Clinical Investigation has the Competent Authority registration number DE/CA126/AP4/3332/18/05.</p

    Algorithm for multi-curve-fitting with shared parameters and a possible application in evoked compound action potential measurements

    Get PDF
    BACKGROUND: Experimental results are commonly fitted by determining parameter values of suitable mathematical expressions. In case a relation exists between different data sets, the accuracy of the parameters obtained can be increased by incorporating this relationship in the fitting process instead of fitting the recordings separately. METHODS: An algorithm to fit multiple measured curves simultaneously was developed. The method accounts for parameters that are shared by some curves. It can be applied to either linear or nonlinear equations. Simulated noisy "measurement results" were created to compare the introduced method to the "straight forward" way of fitting the curves separately. RESULTS: The analysis of the simulated measurements confirm, that the introduced method yields more accurate parameters compared to the ones gained by fitting the measurements separately. Therefore it needs more computer time. As an example, the new fitting algorithm is applied to the measurements of the evoked compound action potentials (ECAP) of the auditory nerve: This leads to promising ideas to reduce artefacts generated by the measuring process. CONCLUSION: The introduced fitting algorithm uses the relationship between multiple measurement results to increase the accuracy of the parameters. Its application in the field of ECAP measurements is promising and should be further investigated

    Modulation Techniques for Biomedical Implanted Devices and Their Challenges

    Get PDF
    Implanted medical devices are very important electronic devices because of their usefulness in monitoring and diagnosis, safety and comfort for patients. Since 1950s, remarkable efforts have been undertaken for the development of bio-medical implanted and wireless telemetry bio-devices. Issues such as design of suitable modulation methods, use of power and monitoring devices, transfer energy from external to internal parts with high efficiency and high data rates and low power consumption all play an important role in the development of implantable devices. This paper provides a comprehensive survey on various modulation and demodulation techniques such as amplitude shift keying (ASK), frequency shift keying (FSK) and phase shift keying (PSK) of the existing wireless implanted devices. The details of specifications, including carrier frequency, CMOS size, data rate, power consumption and supply, chip area and application of the various modulation schemes of the implanted devices are investigated and summarized in the tables along with the corresponding key references. Current challenges and problems of the typical modulation applications of these technologies are illustrated with a brief suggestions and discussion for the progress of implanted device research in the future. It is observed that the prime requisites for the good quality of the implanted devices and their reliability are the energy transformation, data rate, CMOS size, power consumption and operation frequency. This review will hopefully lead to increasing efforts towards the development of low powered, high efficient, high data rate and reliable implanted devices

    Электроснабжение установки перекачки нефти п. Пионерный ОАО «Томскнефть»

    Get PDF
    РЕФЕРАТ Выпускная квалификационная работа 149 с., 23 рис., 32 табл., 29 источников, 6 прил. Ключевые слова: нефтепровод, насос, электрооборудование, схема электроснабжения, линия, сеть, электроприемник, нагрузка, оборудование, защита, ток, напряжение, мощность. Объектом исследования является электрическая часть УПН п. Пионерный ОАО «Томскенефть». Цель работы – проектирование схемы электроснабжения предприятия, выбор оборудования. В процессе исследования проводился сбор исходных данных в ходе производственной практики на объекте исследования. В результате была спроектирована схема электроснабжения от подстанции энергосистемы, до конечного электроприемника. Были выбраны кабели и провода, коммутационное оборудование, были сделаны необходимые проверки. Также результатом работы сталESSAY Final qualifying work 149 p., 23 fig., 32 tab., 29 sources, 6 adj. Keywords: oil, pump, electrical equipment, power supply circuit, line, network, power-consuming equipment, load equipment, protection, current, voltage, power. The object of research is the electrical part of UPN claim. Pionerny of "Tomskeneft". The purpose of work - designing enterprise power scheme, the choice of equipment. The study was conducted to collect baseline data in the course of practical training on the subject of the study. As a result, power supply circuit has been designed from the substation grid, appliance, to the end. Were selected cables and wires, switching equipment, the necessary checks have been made. It is also the result of the work became an economic calculation of capital costs for the con
    corecore