16 research outputs found

    Modulation Techniques for Biomedical Implanted Devices and Their Challenges

    Get PDF
    Implanted medical devices are very important electronic devices because of their usefulness in monitoring and diagnosis, safety and comfort for patients. Since 1950s, remarkable efforts have been undertaken for the development of bio-medical implanted and wireless telemetry bio-devices. Issues such as design of suitable modulation methods, use of power and monitoring devices, transfer energy from external to internal parts with high efficiency and high data rates and low power consumption all play an important role in the development of implantable devices. This paper provides a comprehensive survey on various modulation and demodulation techniques such as amplitude shift keying (ASK), frequency shift keying (FSK) and phase shift keying (PSK) of the existing wireless implanted devices. The details of specifications, including carrier frequency, CMOS size, data rate, power consumption and supply, chip area and application of the various modulation schemes of the implanted devices are investigated and summarized in the tables along with the corresponding key references. Current challenges and problems of the typical modulation applications of these technologies are illustrated with a brief suggestions and discussion for the progress of implanted device research in the future. It is observed that the prime requisites for the good quality of the implanted devices and their reliability are the energy transformation, data rate, CMOS size, power consumption and operation frequency. This review will hopefully lead to increasing efforts towards the development of low powered, high efficient, high data rate and reliable implanted devices

    Instrumentation to Measure the Capacitance of Biosensors by Sinusoidal Wave Method

    No full text
    Micro Controller based instrumentation to measure the capacitance of biosensors is developed. It is based on frequency domain technique with sinusoidal wave input. Changes in the capacitance of biosensor because of the analyte specific reaction are calculated by knowing the current flowing through the sample. A dedicated 8-bit microcontroller (AT89C52) and its associated peripherals are employed for the hardware and application specific software is developed in ‘C’ language. The paper describes the methodology, instrumentation details along with a specific application to glucose sensing. The measurements are conducted with glucose oxidase based capacitance biosensor and the obtained results are compared with the conventional method of sugar measurements using the UV-Visible spectroscopy (Phenol-Sulphuric acid assay method). Measurement accuracy of the instrument is found to be ± 5 %. Experiments are conducted on glucose sensor with different bias voltages. It is found that for bias voltages varying from 0.5 to 0.7 Volt, the measurements are good for this application

    Growth of Polypyrrole-Horseradish Peroxidase Microstructures for H2O2 Biosensor

    No full text
    Conducting polymer microstructures for enzymatic biosensors are developed by a facile electrochemical route. Horseradish peroxide (HRP)-entrapped polypyrrole (PPy) films with bowl-shaped microstructures are developed on stainless steel (SS 304) substrates by a single-step process. Potentiodynamic scanning/cyclic voltammetry is used for generation of PPy microstructures using electrogenerated oxygen bubbles stabilized by zwitterionic surfactant/buffer N-2-hydroxyethylpiperazine N-2-ethanesulfonic acid as soft templates. Scanning electron microscopic images reveal the bowl-shaped structures surrounded by cauliflower-like fractal PPy films and globular nanostructures. Raman spectroscopy reveals the oxidized nature of the film. Sensing properties of PPy-HRP films for hydrogen peroxide (H2O2) are demonstrated. Electrochemical characterization of the sensor films is done by linear sweep voltammetry (LSV) and amperometry. LSV results indicated the reduction of H2O2 and linearity in response of the sensing film. The amperometric biosensor has a performance comparable to those in the literature with advantages of hard-template free synthesis procedure and a satisfactory sensitivity value of 12.8 mu A/(cm(2) . mM) in the range of 1-10 mM H2O2

    Polypyrrole based amperometric glucose biosensors

    No full text
    Biosensors have gained immense acceptance in the field of medical diagnostics, besides environmental, food safety and biodefence applications due to its attributes of real-time and rapid response. This synergistic combination of biotechnology and microelectronics comprises a biological recognition element coupled with a compatible transducer device. Diabetes is a disease of major concern since the ratio of world population suffering from it is increasing at an alarming rate and therefore the need for development of accurate and stable glucose biosensors is evident. There are many commercial glucose biosensors available yet some limitations need attention. This review presents a detailed account of the polypyrrole based amperometric glucose biosensors. The polymer polypyrrole is used extensively as a matrix for immobilization of glucose oxidase enzyme owing to its favourable features such as stability under ambient conditions, conductivity that allows it to be used as an electron relay, ability to be polymerized under neutral and aqueous mild conditions, and more. The simple one-step electrodeposition on the electrode surface allows easy entrapment of the enzyme. The review is structured into three categories (a) the first-stage biosensors: which report the studies from the inception of use of polypyrrole in glucose biosensors during which time the role of the polymer and the use of mediators was established. This period saw extensive work by two separate groups of Schuhmann and Koopal who contributed a great deal in understanding the electron transfer pathways in polypyrrole based glucose biosensors, (b) the second-stage biosensors: which highlight the shift of polypyrrole from a conventional matrix to composite matrices with extensive use of mediators focused at improving the selectivity of response, and (c) third-stage biosensors: the remarkable properties of nanoparticles and carbon nanotubes and their outstanding ability to mediate electrontransfers have seen their indispensable use in conjugation with polypyrrole for development of glucose biosensors with improved sensitivity and stability characteristics which is accounted in the review, which thus traces the evolution of polypyrrole from a conventional matrix, to composites and thence to the form of nanotube arrays, with the objective of addressing the vital issue of diabetes management through the development of stable and reliable glucose biosensors

    On theuse of the Advanced Very High Resolution Radiometer for development of prognostic land surfacephenology models

    No full text
    Regulation of interannual phenological variability is an important component of climate and ecological models. Prior phenological efforts using the advanced very high resolution radiometer (AVHRR) as a proxy of vegetation dynamics have often simulated spring events only or failed to simulate interannual variability. Our aim is to address these shortcomings and to use the AVHRR to develop prognostic models for interannual land surface phenology and, critically, to test whether or not the developed models are superior to use of climatological phenology values from the AVHRR. Using datasets for the conterminous United States, we first filtered data to select regions and plant functional types for which the best-possible remotely sensed signal could be obtained. We then used a generalized linear model approach to model the relationship between an integrative productivity index and estimates of the start of season (SOS) and end of season (EOS) derived from the AVHRR, yielding models capable of prognostically predicting SOS/EOS events independently of satellite data. Mean absolute errors between the model-predicted and AVHRR-observed SOS/EOS ranged from 5.1 to 20.3 days. SOS errors were uniformly lower than EOS errors. SOS models for the deciduous broadleaf forest and grassland plant functional types produced lower errors than use of the climatological SOS values while all other models produced errors higher than those obtained from the climatological dates. Based on this criterion for success, we suggest that the AVHRR may not be appropriate for further development of prognostic land surface phenology models. However, an intercomparison of phenological dates from an independent spring index model, our model predictions, and the AVHRR observations indicated that interannual predictions from our models may be superior to the satellite data upon which they are based, implying that a further comparison between models based on the AVHRR and newer, superior sensors, should be conducted

    Comparative analysis of intravenous midazolam with nasal spray for conscious sedation in minor oral and maxillofacial surgeries

    No full text
    Aim: The aim of the current study was to evaluate the efficacy of nasal spray midazolam by collating it with conventional intravenous midazolam for conscious sedation in minor oral surgeries. Materials and Methods: Sixty patients were selected randomly and divided into two groups: group A for intranasal midazolam atomized spray (n = 30) and group B for intravenous midazolam (n = 30). Physiological parameters, anxiety score, sedation rating, patient’s cooperation score, and retrograde and anterograde amnesia were recorded for each patient during preoperative, intraoperative, and postoperative period. Final evaluation of safety and efficacy in the nasal and intravenous routes of midazolam drug during minor oral surgery was compared. Results: In this study, both intranasal and intravenous groups showed decrease in systolic blood pressure and diastolic blood pressure intraoperatively but within physiological limits and increase in the average pulse rates in both the groups. The average oxygen saturation levels were maintained to normal range in both the groups. The average respiratory rate decreased in both intranasal and intravenous groups during surgical procedure. The preoperative to postoperative anxiety scores were decreased significantly in the both groups and there was no significant difference in pre- to postoperative anxiety scores between the groups. Conclusion: Both intravenous and intranasal administration of midazolam showed better patient cooperation, satisfaction, and clinical effectiveness. Intranasal midazolam spray is effective in the reduction of subjective stress, reliable anxiolysis while preserving protective reflexes
    corecore