1,848 research outputs found
Design and performance of a compact and stationary microSPECT system
Purpose: Over the last ten years, there has been an extensive growth in the development of microSPECT imagers. Most of the systems are based on the combination of conventional, relatively large gamma cameras with poor intrinsic spatial resolution and multipinhole collimators working in large magnification mode. Spatial resolutions range from 0.58 to 0.76 mm while peak sensitivities vary from 0.06% to 0.4%. While pushing the limits of performance is of major importance, the authors believe that there is a need for smaller and less complex systems that bring along a reduced cost. While low footprint and low-cost systems can make microSPECT available to more researchers, the ease of operation and calibration and low maintenance cost are additional factors that can facilitate the use of microSPECT in molecular imaging. In this paper, the authors simulate the performance of a microSPECT imager that combines high space-bandwidth detectors and pinholes with truncated projection, resulting in a small and stationary system. Methods: A system optimization algorithm is used to determine the optimal SPECT systems, given our high resolutions detectors and a fixed field-of-view. These optimal system geometries are then used to simulate a Defrise disk phantom and a hot rod phantom. Finally, a MOBY mouse phantom, with realistic concentrations of Tc99m-tetrofosmin is simulated. Results: Results show that the authors can successfully reconstruct a Defrise disk phantom of 24 mm in diameter without any rotating system components or translation of the object. Reconstructed spatial resolution is approximately 800 mu m while the peak sensitivity is 0.23%. Finally, the simulation of the MOBY mouse phantom shows that the authors can accurately reconstruct mouse images. Conclusions: These results show that pinholes with truncated projections can be used in small magnification or minification mode to obtain a compact and stationary microSPECT system. The authors showed that they can reach state-of-the-art system performance and can successfully reconstruct images with realistic noise levels in a preclinical context. Such a system can be useful for dynamic SPECT imaging. 2013 American Association of Physicists in Medicine
Accurate molecular imaging of small animals taking into account animal models, handling, anaesthesia, quality control and imaging system performance
Small-animal imaging has become an important technique for the development of new radiotracers, drugs and therapies. Many laboratories have now a combination of different small-animal imaging systems, which are being used by biologists, pharmacists, medical doctors and physicists. The aim of this paper is to give an overview of the important factors in the design of a small animal, nuclear medicine and imaging experiment. Different experts summarize one specific aspect important for a good design of a small-animal experiment
rSPECT: a compact gamma camera based SPECT system for small-animal imaging
Proceeding of: 2009 IEEE Nuclear Science Symposium Conference Record (NSS/MIC), Orlando, Florida, 25-31 October 2009We have developed a compact and modular gamma
camera system and assessed its performance when used on a small-animal SPECT prototype (rSPECT). Each camera consists of a Hamamatsu H-8500 position sensitive photomultiplier tube coupled to a 30 x 30 NaI (Tl) scintillator array (1.4mm x 1.4mm x
6mm crystal size) and electronics for pre-processing and matching the detector signals to an in-house developed data
acquisition system. The camera components are enclosed in a lead-shielded case with a receptacle to insert the collimators
(parallel-hole or pinhole with different tungsten apertures).
System performance has been assessed for a low energy high resolution parallel-hole collimator (LEHR), and for a 0.75 mm
pinhole collimator with 60º aperture angle. In this paper we present details on the system implementation and results of
performance measurements, as well as first tomographic images on phantoms and animals. This SPECT was conceived for compactness and cost-effective routine small-animal imaging,
and acquisitions of living mice and rats carried out with the system demonstrate its ability to provide useful high-resolution
images for in vivo research.This work is partially funded by the CD TEAM project, CENIT Program, Spanish Ministerio de Industria and with grants from the Ministerio de Educación y Ciencia, Projects TEC2007 64731/TCM, TEC2008 06715 C02
01, SAF2009 08076 and the RECAVA RETIC Network
A spect scanner for rodent imaging based on small-area gamma cameras
We developed a cost-effective SPECT scanner prototype
(rSPECT) for in vivo imaging of rodents based on small-area
gamma cameras. Each detector consists of a position-sensitive photomultiplier
tube (PS-PMT) coupled to a 30 30 NaI(Tl) scintillator
array and electronics attached to the PS-PMT sockets for
adapting the detector signals to an in-house developed data acquisition
system. The detector components are enclosed in a leadshielded
case with a receptacle to insert the collimators. System
performance was assessed using for a high-resolution parallel-
hole collimator, and for a 0.75-mm pinhole collimator with a
60 aperture angle and a 42-mm collimator length. The energy resolution
is about 10.7% of the photopeak energy. The overall system
sensitivity is about
and planar spatial resolution
ranges from 2.4 mm at 1 cm source-to-collimator distance
to 4.1 mm at 4.5 cm with parallel-hole collimators. With pinhole
collimators planar spatial resolution ranges from 1.2 mm at 1 cm
source-to-collimator distance to 2.4 mm at 4.5 cm; sensitivity at
these distances ranges from 2.8 to
. Tomographic
hot-rod phantom images are presented together with
images of bone, myocardium and brain of living rodents to demonstrate
the feasibility of preclinical small-animal studies with the
rSPECT.This work was supported in part by the CD-TEAM project, CENIT program, Spanish Ministerio de Industria and with grants from the Ministerio de Educación y Ciencia, Projects TEC2007-64731/TCM, TEC2008-06715-C02-01, SAF2009-08076, program ARTEMIS S2009/DPI-1802, Comunidad de Madrid, and the RECAVA-RETIC NetworkPublicad
Methodological approaches to planar and volumetric scintigraphic imaging of small volume targets with high spatial resolution and sensitivity
Single-photon emission computed tomography (SPECT) is a non-invasive imaging technique, which provides information reporting the functional states of tissues. SPECT imaging has been used as a diagnostic tool in several human disorders and can be used in animal models of diseases for physiopathological, genomic and drug discovery studies. However, most of the experimental models used in research involve rodents, which are at least one order of magnitude smaller in linear dimensions than man. Consequently, images of targets obtained with conventional gamma-cameras and collimators have poor spatial resolution and statistical quality. We review the methodological approaches developed in recent years in order to obtain images of small targets with good spatial resolution and sensitivity. Multipinhole, coded mask- and slit-based collimators are presented as alternative approaches to improve image quality. In combination with appropriate decoding algorithms, these collimators permit a significant reduction of the time needed to register the projections used to make 3-D representations of the volumetric distribution of target’s radiotracers. Simultaneously, they can be used to minimize artifacts and blurring arising when single pinhole collimators are used. Representation images are presented, which illustrate the use of these collimators. We also comment on the use of coded masks to attain tomographic resolution with a single projection, as discussed by some investigators since their introduction to obtain near-field images. We conclude this review by showing that the use of appropriate hardware and software tools adapted to conventional gamma-cameras can be of great help in obtaining relevant functional information in experiments using small animals.FAPESPFAPESP CInAPC
Iodine-123 labeled reboxetine analogues for imaging of noradrenaline transporter in brain using single photon emission computed tomography
Preliminary investigation of the radioiodinated (S,S)-reboxetine analogue, 123I-INER, in baboons showed this tracer to have promise for imaging the noradrenaline transporter (NAT) using single photon emission computed tomography (SPECT). More recently, the radioiodinated (R,S)-stereoisomer of 123I-INER, 123I-NKJ64, has been synthesized and preliminary evaluation in rats has been reported. This article reports the brain distribution and pharmacokinetic properties of 123I-NKJ64 in baboons and compares results with 123I-INER data in the same species. SPECT studies were conducted in two ovariectomized adult female baboons using two different protocols: (1) bolus of 123I-INER or 123I-NKJ64; and (2) bolus plus constant infusion of 123I-NKJ64 with reboxetine (2.0 mg/kg) administration at equilibrium. Following bolus injection, both radiotracers rapidly and avidly entered the baboon brain. The regional brain accumulation of 123I-NKJ64 did not match the known distribution of NAT in baboon brain, contrasting with previous results obtained in rats. Conversely, the regional distribution of 123I-INER was consistent with known distribution of NAT in baboon brain. No displacement of 123I-NKJ64 was observed following administration of reboxetine. This contrasts with previous data obtained for 123I-INER, where 60% of specific binding was displaced by a lower dose of reboxetine. These data suggest that 123I-NKJ64 may lack affinity and selectivity for NAT in baboon brain and 123I-INER is the most promising iodinated reboxetine analogue developed to date for in vivo imaging of NAT in brain using SPECT. This study highlights the importance of species differences during radiotracer development and the stereochemical configuration of analogues of reboxetine in vivo. Synapse, 2012. -® 2012 Wiley Periodicals, In
Improved image quality in pinhole SPECT by accurate modeling of the point spread function in low magnification systems
PURPOSE: Single photon emission computed tomography (SPECT) has become an important noninvasive imaging technique in small-animal research. Due to the high resolution required in small-animal SPECT systems, the spatially variant system response needs to be included in the reconstruction algorithm. Accurate modeling of the system response should result in a major improvement in the quality of reconstructed images. The aim of this study was to quantitatively assess the impact that an accurate modeling of spatially variant collimator/detector response has on image-quality parameters, using a low magnification SPECT system equipped with a pinhole collimator and a small gamma camera. METHODS: Three methods were used to model the point spread function (PSF). For the first, only the geometrical pinhole aperture was included in the PSF. For the second, the septal penetration through the pinhole collimator was added. In the third method, the measured intrinsic detector response was incorporated. Tomographic spatial resolution was evaluated and contrast, recovery coefficients, contrast-to-noise ratio, and noise were quantified using a custom-built NEMA NU 4-2008 image-quality phantom. RESULTS: A high correlation was found between the experimental data corresponding to intrinsic detector response and the fitted values obtained by means of an asymmetric Gaussian distribution. For all PSF models, resolution improved as the distance from the point source to the center of the field of view increased and when the acquisition radius diminished. An improvement of resolution was observed after a minimum of five iterations when the PSF modeling included more corrections. Contrast, recovery coefficients, and contrast-to-noise ratio were better for the same level of noise in the image when more accurate models were included. Ring-type artifacts were observed when the number of iterations exceeded 12. CONCLUSIONS: Accurate modeling of the PSF improves resolution, contrast, and recovery coefficients in the reconstructed images. To avoid the appearance of ring-type artifacts, the number of iterations should be limited. In low magnification systems, the intrinsic detector PSF plays a major role in improvement of the image-quality parameters.Gobierno de EspañaCDTI-CENIT (AMIT project)Instituto de Salud Carlos III (ISCIII
- …