46 research outputs found

    Speckle Noise Reduction in Medical Ultrasound Images

    Get PDF
    Ultrasound imaging is an incontestable vital tool for diagnosis, it provides in non-invasive manner the internal structure of the body to detect eventually diseases or abnormalities tissues. Unfortunately, the presence of speckle noise in these images affects edges and fine details which limit the contrast resolution and make diagnostic more difficult. In this paper, we propose a denoising approach which combines logarithmic transformation and a non linear diffusion tensor. Since speckle noise is multiplicative and nonwhite process, the logarithmic transformation is a reasonable choice to convert signaldependent or pure multiplicative noise to an additive one. The key idea from using diffusion tensor is to adapt the flow diffusion towards the local orientation by applying anisotropic diffusion along the coherent structure direction of interesting features in the image. To illustrate the effective performance of our algorithm, we present some experimental results on synthetically and real echographic images

    wKSR-NLM: An Ultrasound Despeckling Filter Based on Patch Ratio and Statistical Similarity

    Get PDF
    Ultrasound images are affected by the well known speckle phenomenon, that degrades their perceived quality. In recent years, several denoising approaches have been proposed. Among all, those belonging to the non-local (NL) family have shown interesting performance. The main difference among the proposed NL filters is the metric adopted for measuring the similarity between patches. Within this manuscript, a statistical metric based on the ratio between two patches is presented. Compared to other statistical measurements, the proposed one is able to take into account the texture of the patch, to consider a weighting kernel and to limit the computational burden. A comparative analysis with other despeckling filters is presented. The method provided good balance between noise reduction and details preserving both in case of simulated (by means of Field II software) and real (breast tumor) datasets

    Ultrasound Image Despeckling using Local Binary Pattern Weighted Linear Filtering

    Full text link

    A Tutorial on Speckle Reduction in Synthetic Aperture Radar Images

    Get PDF
    Speckle is a granular disturbance, usually modeled as a multiplicative noise, that affects synthetic aperture radar (SAR) images, as well as all coherent images. Over the last three decades, several methods have been proposed for the reduction of speckle, or despeckling, in SAR images. Goal of this paper is making a comprehensive review of despeckling methods since their birth, over thirty years ago, highlighting trends and changing approaches over years. The concept of fully developed speckle is explained. Drawbacks of homomorphic filtering are pointed out. Assets of multiresolution despeckling, as opposite to spatial-domain despeckling, are highlighted. Also advantages of undecimated, or stationary, wavelet transforms over decimated ones are discussed. Bayesian estimators and probability density function (pdf) models in both spatial and multiresolution domains are reviewed. Scale-space varying pdf models, as opposite to scale varying models, are promoted. Promising methods following non-Bayesian approaches, like nonlocal (NL) filtering and total variation (TV) regularization, are reviewed and compared to spatial- and wavelet-domain Bayesian filters. Both established and new trends for assessment of despeckling are presented. A few experiments on simulated data and real COSMO-SkyMed SAR images highlight, on one side the costperformance tradeoff of the different methods, on the other side the effectiveness of solutions purposely designed for SAR heterogeneity and not fully developed speckle. Eventually, upcoming methods based on new concepts of signal processing, like compressive sensing, are foreseen as a new generation of despeckling, after spatial-domain and multiresolution-domain method

    Effect of kernel size on Wiener and Gaussian image filtering

    Get PDF
    In this paper, the effect of the kernel size of Wiener and Gaussian filters on their image restoration qualities has been studied and analyzed. Four sizes of such kernels, namely 3x3, 5x5, 7x7 and 9x9 were simulated. Two different types of noise with zero mean and several variances have been used: Gaussian noise and speckle noise. Several image quality measuring indices have been applied in the computer simulations. In particular, mean absolute error (MAE), mean square error (MSE) and structural similarity (SSIM) index were used. Many images were tested in the simulations; however the results of three of them are shown in this paper. The results show that the Gaussian filter has a superior performance over the Wiener filter for all values of Gaussian and speckle noise variances mainly as it uses the smallest kernel size. To obtain a similar performance in Wiener filtering, a larger kernel size is required which produces much more blur in the output mage. The Wiener filter shows poor performance using the smallest kernel size (3x3) while the Gaussian filter shows the best results in such case. With the Gaussian filter being used, similar results of those obtained with low noise could be obtained in the case of high noise variance but with a higher kernel size

    Anisotropic Diffusion Filter with Memory based on Speckle Statistics for Ultrasound Images

    Get PDF
    Ultrasound imaging exhibits considerable difficulties for medical visual inspection and for the development of automatic analysis methods due to speckle, which negatively affects the perception of tissue boundaries and the performance of automatic segmentation methods. With the aim of alleviating the effect of speckle, many filtering techniques are usually considered as a preprocessing step prior to automatic analysis methods or visual inspection. Most of the state-of-the-art filters try to reduce the speckle effect without considering its relevance for the characterization of tissue nature. However, the speckle phenomenon is the inherent response of echo signals in tissues and can provide important features for clinical purposes. This loss of information is even magnified due to the iterative process of some speckle filters, e.g., diffusion filters, which tend to produce over-filtering because of the progressive loss of relevant information for diagnostic purposes during the diffusion process. In this work, we propose an anisotropic diffusion filter with a probabilistic-driven memory mechanism to overcome the over-filtering problem by following a tissue selective philosophy. Specifically, we formulate the memory mechanism as a delay differential equation for the diffusion tensor whose behavior depends on the statistics of the tissues, by accelerating the diffusion process in meaningless regions and including the memory effect in regions where relevant details should be preserved. Results both in synthetic and real US images support the inclusion of the probabilistic memory mechanism for maintaining clinical relevant structures, which are removed by the state-of-the-art filters

    Speckle Noise Reduction in Medical Ultrasound Images Using Modelling of Shearlet Coefficients as a Nakagami Prior

    Get PDF
    The diagnosis of UltraSound (US) medical images is affected due to the presence of speckle noise. This noise degrades the diagnostic quality of US images by reducing small details and edges present in the image. This paper presents a novel method based on shearlet coefficients modeling of log-transformed US images. Noise-free log-transformed coefficients are modeled as Nakagami distribution and speckle noise coefficients are modeled as Gaussian distribution. Method of Log Cumulants (MoLC) and Method of Moments (MoM) are used for parameter estimation of Nakagami distribution and noise free shearlet coefficients respectively. Then noise free shearlet coefficients are obtained using Maximum a Posteriori (MaP) estimation of noisy coefficients. The experimental results were presented by performing various experiments on synthetic and real US images. Subjective and objective quality assessment of the proposed method is presented and is compared with six other existing methods. The effectiveness of the proposed method over other methods can be seen from the obtained results

    Post-processing approaches for the improvement of cardiac ultrasound B-mode images:a review

    Get PDF
    corecore