17,991 research outputs found

    Compensation of Distribution System Voltage using DVR

    Get PDF
    A dynamic voltage restorer (DVR) is a power-electronic controller that can protect sensitive loads from disturbances in the supply system. In this paper, it is demonstrated that this device can tightly regulate the voltage at the load terminal against imbalance or harmonic in the source side. The behavior of the device is studied through steady-state analysis, and limits to achievable performance are found. This analysis is extended to the study of transient operation where the generation of the reference voltage of the DVR is discussed. Once the reference signals are generated, they are tracked using a switching band scheme. A suitable structure in which the DVR is realized by voltage-source inverters (VSIs) is also discussed. Particular emphasis to the rating of this device is provided. Extensive simulation results are included to illustrate the operating principles of a DVR

    Hacking Digital Video Recorders: Potential Copyright Liability for DVR Hackers and Service Providers

    Get PDF
    To what extent does Sony\u27s time-shifting fair use argument extend to recent innovations that make it easier for hackers use DVR technology to generate copies of protected material? The author assesses the potential liability of DVR manufacturers against the backdrop of traditional fair use doctrines

    Finite elements and the discrete variable representation in nonequilibrium Green's function calculations. Atomic and molecular models

    Get PDF
    In this contribution, we discuss the finite-element discrete variable representation (FE-DVR) of the nonequilibrium Green's function and its implications on the description of strongly inhomogeneous quantum systems. In detail, we show that the complementary features of FEs and the DVR allows for a notably more efficient solution of the two-time Schwinger/Keldysh/Kadanoff-Baym equations compared to a general basis approach. Particularly, the use of the FE-DVR leads to an essential speedup in computing the self-energies. As atomic and molecular examples we consider the He atom and the linear version of H3+_3^+ in one spatial dimension. For these closed-shell models we, in Hartree-Fock and second Born approximation, compute the ground-state properties and compare with the exact findings obtained from the solution of the few-particle time-dependent Schr\"odinger equation.Comment: 12 pages, 3 figures, submitted as proceedings of conference "PNGF IV

    Performance Evaluation of Three Different Inverter Configurations of DVR for Mitigation of Voltage Events

    Get PDF
    The voltage events namely voltage sags and voltage swells represent the most common, frequent and important power quality events in today’s power system. Dynamic voltage restorer (DVR) is one of the key components used to mitigate the supply voltage quality disturbances in terms of voltage sags and swells in the distribution system. It consists of an energy storage unit, a voltage source inverter, a filter, a coupling transformer and the control system. This paper presents three different inverter configurations of dynamic voltage restorer (DVR) for mitigation of voltage events such as voltage sags and swells with sudden addition or removal of the nonlinear load. These three configurations are voltage source inverter based DVR (VSI-DVR), current source inverter based DVR (CSI-DVR) and impedance or Z-source inverter based DVR (ZSI-DVR). The d-q control technique is used to control the operation of the DVR. The response of ZSI-DVR for mitigation of voltage sags and swells are investigated and compared with VSI-DVR and CSI-DVR using MATLAB/SIMULINK environment

    Use of the Discrete Variable Representation Basis in Nuclear Physics

    Full text link
    The discrete variable representation (DVR) basis is nearly optimal for numerically representing wave functions in nuclear physics: Suitable problems enjoy exponential convergence, yet the Hamiltonian remains sparse. We show that one can often use smaller basis sets than with the traditional harmonic oscillator basis, and still benefit from the simple analytic properties of the DVR bases which requires no overlap integrals, simply permit using various Jacobi coordinates, and admit straightforward analyses of the ultraviolet and infrared convergence properties.Comment: Published version: New figure demonstrating convergence for 3- and 4-body problem

    Renal pericytes: regulators of medullary blood flow

    Get PDF
    Regulation of medullary blood flow (MBF) is essential in maintaining normal kidney function. Blood flow to the medulla is supplied by the descending vasa recta (DVR), which arise from the efferent arterioles of juxtamedullary glomeruli. DVR are composed of a continuous endothelium, intercalated with smooth muscle-like cells called pericytes. Pericytes have been shown to alter the diameter of isolated and in situ DVR in response to vasoactive stimuli that are transmitted via a network of autocrine and paracrine signalling pathways. Vasoactive stimuli can be released by neighbouring tubular epithelial, endothelial, red blood cells and neuronal cells in response to changes in NaCl transport and oxygen tension. The experimentally described sensitivity of pericytes to these stimuli strongly suggests their leading role in the phenomenon of MBF autoregulation. Because the debate on autoregulation of MBF fervently continues, we discuss the evidence favouring a physiological role for pericytes in the regulation of MBF and describe their potential role in tubulo-vascular cross-talk in this region of the kidney. Our review also considers current methods used to explore pericyte activity and function in the renal medulla

    KOMBINASI FEED BACK DAN FEED FORWARD KONTROLLER PI SEBAGAI KENDALI DYNAMIC VOLTAGE RESTORER (DVR) UNTUK MEMULIHKAN VOLTAGE SAG DAN INTERRUPTION

    Get PDF
    Dynamic voltage restorer (DVR) is one of equipments to protect sensitive load from voltage drop. DVR is installed series with line feeder by serial transformer which injecting voltage when under voltage occurs. This research is investigate the capability of DVR, which controlled by combination of feed back and feed forward PI, to handle voltage sag and interruption. DVR controls have been designed and implemented in DVR prototype. As a result, in simulation, DVR can maintain voltage in range 90% - 105% nominal voltage. Voltage at load side can be restored to 1 pu and 0.79 pu when voltage sag and interruption respectively. Furthermore, DVR prototype can restore 0.95 pu when voltage sag and 0.54 pu when interruption

    Advanced Control of the dynamic voltage restorer for mitigating voltage sags in power systems

    Get PDF
    The paper presents a vector control with two cascaded loops to improve the properties of Dynamic Voltage Restorer (DVR) to minimize Voltage Sags on the grid. Thereby, a vector controlled structure was built on the rotating dq-coordinate system with the combination of voltage control and the current control. The proposed DVR control method is modelled using MATLAB-Simulink. It is tested using balanced/ unbalanced voltage sags as well as fluctuant and distorted voltages. As a result, by using this controlling method, the dynamic characteristics of the system have been improved significantly. The system performed with higher accuracy, faster response and lower distortion in the voltage sags compensation. The paper presents real time experimental results to verify the performance of the proposed method in real environments
    corecore