840 research outputs found

    Active Comb Filter Using Voltage Differencing Transconductance Amplifiers

    Get PDF
    A new active comb filter employing Voltage Differencing Transconductance Amplifiers (VDTAs) is proposed to eliminate the selected frequencies of different signals. The proposed filter is based on VDTAs, capacitors and resistors. The functionality of the circuit is verified using PSPICE with TSMC CMOS 0.18µm process parameters for test signals of 50, 150, 250, and 350 Hz

    Fibre segment interferometry using code-division multiplexed optical signal processing for strain sensing applications

    Get PDF
    A novel optical signal processing scheme for multiplexing fibre segment interferometers is proposed. The continuous-wave, homodyne technique combines code-division multiplexing with single-sideband modulation. It uses only one electro-optic phase modulator to achieve both range separation and quadrature interferometric phase measurement. This scheme is applied to fibre segment interferometry, where a number of long-gauge length interferometric fibre sensors are formed by subtracting pairs of signals from equidistantly placed, weak back reflectors. In this work we give a detailed account of the signal processing involved and, in particular, explore aspects such as electronic bandwidth requirements, noise, crosstalk and linearity, which are important design considerations. A signal bandwidth of ±20 kHz permits the resolution of phase change rates of 2.5 × 104 rad s-1 for each of the four 16.5 m long segments in our setup. We show that dynamic strain resolutions below 0.2 nanostrain Hz-0.5 at 2 m sensor gauge length are achievable, even with an inexpensive diode laser. When used in applications that require only relative strain change measurements, this scheme compares well to more established techniques and can provide high-fidelity yet cost-effective measurements

    Sensor Developments for Electrophysiological Monitoring in Healthcare

    Get PDF
    Recent years have seen a renewal of interest in the development of sensor systems which can be used to monitor electrophysiological signals in a number of different settings. These include clinical, outside of the clinical setting with the subject ambulatory and going about their daily lives, and over long periods. The primary impetus for this is the challenge of providing healthcare for the ageing population based on home health monitoring, telehealth and telemedicine. Another stimulus is the demand for life sign monitoring of critical personnel such as fire fighters and military combatants. A related area of interest which, whilst not in the category of healthcare, utilises many of the same approaches, is that of sports physiology for both professional athletes and for recreation. Clinical diagnosis of conditions in, for example, cardiology and neurology remain based on conventional sensors, using established electrodes and well understood electrode placements. However, the demands of long term health monitoring, rehabilitation support and assistive technology for the disabled and elderly are leading research groups such as ours towards novel sensors, wearable and wireless enabled systems and flexible sensor arrays

    THE APPLICATION OF LEAKY WAVE ANTENNAS FOR MEDICAL HYPERTHERMIA TREATMENT AND BEAMFORMER IN FMCW AUTOMOTIVE RADAR SYSTEMS

    Get PDF
    Thousands of years ago human discovered that if a slice of amber is rubbed against fur, it would absorb light-weight objects. Hundreds of years after that the ancient people figured out that there are actually two different characteristics of attraction and repulsion. Another 2000 years passed when human discovered that these two wonders of nature, magnetism and electricity are actually linked together like the two sides of the same coin. Since then, in the early 19th century great huge achievements were made in antennas and propagation by scientists such as Hans Christen Oersted, Heinrich Hertz, Alexander Popov and Marconi. Since then, antennas have found their enormous applications in military, medical and industrial arenas. In the endless world of antennas, we have picked up leaky wave antennas to further investigate their interesting properties and worked on at least 2 applications of such propagation systems in the medical field as well as in automotive field such as road safety. In our research, we have designed one-dimensional and two-dimensional leaky wave antennas to apply the main beam to the cancerous tissue by using the beam scanning property of these antennas. We could shift the main beam to another location in the tissue. Two-dimensional leaky wave antennas provide more beam flexibility in terms of beam geometry and beam displacement which will be discussed in the corresponding chapters. Improving road safety with equipping vehicles with sensing systems such as frequency modulated continuous wave (FMCW) automotive radar systems is one of the most interesting topics in radar engineering. Surely, the main factor that could influence the mass production of cheap radar systems for automobiles is influenced by what antenna system is designed for that radar system. In this dissertation, we have proposed an FMCW radar system using a cheap antenna solution. The proposed antenna system is comb-line leaky wave antenna. The performance of the proposed radar system has been evaluated using range-Doppler graphs and we have also discussed a common problem in multi-target FMCW radar systems which is the issue of the ghost targets

    Integrated nanophotonic waveguide-based devices for IR and Raman gas spectroscopy

    Get PDF
    On-chip devices for absorption spectroscopy and Raman spectroscopy have been developing rapidly in the last few years, triggered by the growing availability of compact and affordable tunable lasers, detectors, and on-chip spectrometers. Material processing that is compatible with mass production has been proven to be capable of long low-loss waveguides of sophisticated designs, which are indispensable for high-light–analyte interactions. Sensitivity and selectivity have been further improved by the development of sorbent cladding. In this review, we discuss the latest advances and challenges in the field of waveguide-enhanced Raman spectroscopy (WERS) and waveguide infrared absorption spectroscopy (WIRAS). The development of integrated light sources and detectors toward miniaturization will be presented, together with the recent advances on waveguides and cladding to improve sensitivity. The latest reports on gas-sensing applications and main configurations for WERS and WIRAS will be described, and the most relevant figures of merit and limitations of different sensor realizations summarized

    Advanced bioelectrical signal processing methods: Past, present and future approach - Part III: Other biosignals

    Get PDF
    Analysis of biomedical signals is a very challenging task involving implementation of various advanced signal processing methods. This area is rapidly developing. This paper is a Part III paper, where the most popular and efficient digital signal processing methods are presented. This paper covers the following bioelectrical signals and their processing methods: electromyography (EMG), electroneurography (ENG), electrogastrography (EGG), electrooculography (EOG), electroretinography (ERG), and electrohysterography (EHG).Web of Science2118art. no. 606

    Photonic integrated components for optical coherence tomography

    Get PDF

    Optical code-division multiple access system and optical signal processing

    Get PDF
    This thesis presents our recent researches on the development of coding devices, the investigation of security and the design of systems in the optical cod-division multiple access (OCDMA) systems. Besides, the techniques of nonlinear signal processing used in the OCDMA systems fire our imagination, thus some researches on all-optical signal processing are carried out and also summarized in this thesis. Two fiber Bragg grating (FBG) based coding devices are proposed. The first coding device is a superstructured FBG (SSFBG) using ±π/2-phase shifts instead of conventional 0/π-phase shifts. The ±π/2-phase-shifted SSFBG en/decoders can not only conceal optical codes well in the encoded signals but also realize the reutilization of available codes by hybrid use with conventional 0/π-phase-shifted SSFBG en/decoders. The second FBG based coding device is synthesized by layer-peeling method, which can be used for simultaneous optical code recognition and chromatic dispersion compensation. Then, two eavesdropping schemes, one-bit delay interference detection and differential detection, are demonstrated to reveal the security vulnerability of differential phase-shift keying (DPSK) and code-shift keying (CSK) OCDMA systems. To address the security issue as well as increase the transmission capacity, an orthogonal modulation format based on DPSK and CSK is introduced into the OCDMA systems. A 2 bit/symbol 10 Gsymbol/s transmission system using the orthogonal modulation format is achieved. The security of the system can be partially guaranteed. Furthermore, a fully-asynchronous gigabit-symmetric OCDMA passive optical network (PON) is proposed, in which a self-clocked time gate is employed for signal regeneration. A remodulation scheme is used in the PON, which let downstream and upstream share the same optical carrier, allowing optical network units source-free. An error-free 4-user 10 Gbit/s/user duplex transmission over 50 km distance is reazlied. A versatile waveform generation scheme is then studied. A theoretical model is established and a waveform prediction algorithm is summarized. In the demonstration, various waveforms are generated including short pulse, trapezoidal, triangular and sawtooth waveforms and doublet pulse. ii In addition, an all-optical simultaneous half-addition and half-subtraction scheme is achieved at an operating rate of 10 GHz by using only two semiconductor optical amplifiers (SOA) without any assist light. Lastly, two modulation format conversion schemes are demonstrated. The first conversion is from NRZ-OOK to PSK-Manchester coding format using a SOA based Mach-Zehnder interferometer. The second conversion is from RZ-DQPSK to RZ-OOK by employing a supercontinuum based optical thresholder

    Multimodal Wearable Sensors for Human-Machine Interfaces

    Get PDF
    Certain areas of the body, such as the hands, eyes and organs of speech production, provide high-bandwidth information channels from the conscious mind to the outside world. The objective of this research was to develop an innovative wearable sensor device that records signals from these areas more conveniently than has previously been possible, so that they can be harnessed for communication. A novel bioelectrical and biomechanical sensing device, the wearable endogenous biosignal sensor (WEBS), was developed and tested in various communication and clinical measurement applications. One ground-breaking feature of the WEBS system is that it digitises biopotentials almost at the point of measurement. Its electrode connects directly to a high-resolution analog-to-digital converter. A second major advance is that, unlike previous active biopotential electrodes, the WEBS electrode connects to a shared data bus, allowing a large or small number of them to work together with relatively few physical interconnections. Another unique feature is its ability to switch dynamically between recording and signal source modes. An accelerometer within the device captures real-time information about its physical movement, not only facilitating the measurement of biomechanical signals of interest, but also allowing motion artefacts in the bioelectrical signal to be detected. Each of these innovative features has potentially far-reaching implications in biopotential measurement, both in clinical recording and in other applications. Weighing under 0.45 g and being remarkably low-cost, the WEBS is ideally suited for integration into disposable electrodes. Several such devices can be combined to form an inexpensive digital body sensor network, with shorter set-up time than conventional equipment, more flexible topology, and fewer physical interconnections. One phase of this study evaluated areas of the body as communication channels. The throat was selected for detailed study since it yields a range of voluntarily controllable signals, including laryngeal vibrations and gross movements associated with vocal tract articulation. A WEBS device recorded these signals and several novel methods of human-to-machine communication were demonstrated. To evaluate the performance of the WEBS system, recordings were validated against a high-end biopotential recording system for a number of biopotential signal types. To demonstrate an application for use by a clinician, the WEBS system was used to record 12‑lead electrocardiogram with augmented mechanical movement information

    Hyperspectral interferometry for single-shot profilometry and depth-resolved displacement field measurement

    Get PDF
    A new approach to the absolute measurement of two-dimensional optical path differences is presented in this thesis. The method, which incorporates a white light interferometer and a hyperspectral imaging system, is referred to as Hyperspectral Interferometry. A prototype of the Hyperspectral Interferometry (HSI) system has been designed, constructed and tested for two types of measurement: for surface profilometry and for depth-resolved displacement measurement, both of which have been implemented so as to achieve single shot data acquisition. The prototype has been shown to be capable of performing a single-shot 3-D shape measurement of an optically-flat step-height sample, with less than 5% difference from the result obtained by a standard optical (microscope) based method. The HSI prototype has been demonstrated to be able to perform single-shot measurement with an unambiguous 352 (m depth range and a rms measurement error of around 80 nm. The prototype has also been tested to perform measurements on optically rough surfaces. The rms error of these measurements was found to increase to around 4× that of the smooth surface. For the depth-resolved displacement field measurements, an experimental setup was designed and constructed in which a weakly-scattering sample underwent simple compression with a PZT actuator. Depth-resolved displacement fields were reconstructed from pairs of hyperspectral interferograms. However, the experimental results did not show the expected result of linear phase variation with depth. Analysis of several possible causes has been carried out with the most plausible reasons being excessive scattering particle density inside the sample and the possibility of insignificant deformation of the sample due to insufficient physical contact between the transducer and the sample
    corecore