13,244 research outputs found

    A novel endurance prediction method of series connected lithium-ion batteries based on the voltage change rate and iterative calculation.

    Get PDF
    High-power lithium-ion battery packs are widely used in large and medium-sized unmanned aerial vehicles and other fields, but there is a safety hazard problem with the application that needs to be solved. The generation mechanism and prevention measurement research is carried out on the battery management system for the unmanned aerial vehicles and the lithium-ion battery state monitoring. According to the group equivalent modeling demand of the battery packs, a new idea of compound equivalent circuit modeling is proposed and the model constructed to realize the accurate description of the working characteristics. In order to realize the high-precision state prediction, the improved unscented Kalman feedback correction mechanism is introduced, in which the simplified particle transforming is introduced and the voltage change rate is calculated to construct a new endurance prediction model. Considering the influence of the consistency difference between battery cells, a novel equilibrium state evaluation idea is applied, the calculation results of which are embedded in the equivalent modeling and iterative calculation to improve the prediction accuracy. The model parameters are identified by the Hybrid Pulse Power Characteristic test, in which the conclusion is that the mean value of the ohm internal resistance is 20.68mΩ. The average internal resistance is 1.36mΩ, and the mean capacitance value is 47747.9F. The state of charge prediction error is less than 2%, which provides a feasible way for the equivalent modeling, battery management system design and practical application of pack working lithium-ion batteries

    Powering a Biosensor Using Wearable Thermoelectric Technology

    Get PDF
    Wearable medical devices such as insulin pumps, glucose monitors, hearing aids, and electrocardiograms provide necessary medical aid and monitoring to millions of users worldwide. These battery powered devices require battery replacement and frequent charging that reduces the freedom and peace of mind of users. Additionally, the significant portion of the world without access to electricity is unable to use these medical devices as they have no means to power them constantly. Wearable thermoelectric power generation aims to charge these medical device batteries without a need for grid power. Our team has developing a wristband prototype that uses body heat, ambient air, and heat sinks to create a temperature difference across thermoelectric modules thus generating ultra-low voltage electrical power. A boost converter is implemented to boost this voltage to the level required by medical device batteries. Our goal was to use this generated power to charge medical device batteries off-the-grid, increasing medical device user freedom and allowing medical device access to those without electricity. We successfully constructed a wearable prototype that generates the voltage required by an electrocardiogram battery; however, further thermoelectric module and heat dissipation optimization is necessary to generate sufficient current to charge the battery

    Systematic approach for the test data generation and validation of ISC/ESC detection methods

    Get PDF
    Various methods published in recent years for reliable detection of battery faults (mainly internal short circuit (ISC)) raise the question of comparability and cross-method evaluation, which cannot yet be answered due to significant differences in training data and boundary conditions. This paper provides a Monte Carlo-like simulation approach to generate a reproducible, comprehensible and large dataset based on an extensive literature search on common assumptions and simulation parameters. In some cases, these assumptions are quite different from field data, as shown by comparison with experimentally determined values. Two relatively simple ISC detection methods are tested on the generated dataset and their performance is evaluated to illustrate the proposed approach. The evaluation of the detection performance by quantitative measures such as the Youden-index shows a high divergence with respect to internal and external parameters such as threshold level and cell-to-cell variations (CtCV), respectively. These results underline the importance of quantitative evaluations based on identical test data. The proposed approach is able to support this task by providing cost-effective test data generation with incorporation of known factors affecting detection quality

    Accelerated internal resistance measurements of lithium-ion cells to support future end-of-life strategies for electric vehicles

    Get PDF
    Industrial and academic communities have embarked on investigating the sustainability of vehicles that contain embedded electrochemical energy storage systems. Circular economy strategies for electric vehicle (EV) or hybrid electric vehicle (HEV) battery systems are underpinned by implicit assumptions about the state of health (SOH) of the battery. The internal resistance of battery systems is the essential property for determining available power, energy efficiency, and heat generation. Consequently, precise measurement is crucial to estimate the SOH; however, the international standards and best practice guides that exist to define the measurements include long preconditioning and rest times that make the test duration prohibitive. The aim of this research is to critically evaluate whether test duration times for internal resistance measurements can be reduced to values that may facilitate further end-of-life (EOL) options. Results reveal a newly developed technique using pulse-multisines is two to four times faster to perform when compared to the standard protocol whilst maintaining accuracy for battery electric vehicle (BEV) and HEV cells, respectively. This novel method allows different stakeholders to rank the relative importance of test accuracy verses experimental test time when categorising used Li-ion cells for different EOL applications. View Full-Tex

    Creep monitoring using permanently installed potential drop sensors

    Get PDF
    Creep is the primary life limiting mechanism of static high temperature, high pressure power station components. Creep state evaluation is currently achieved by surface inspection of microstructure during infrequent outages; a methodology which is laborious, time consuming and considered inadequate. The objective of this work is to develop a monitoring technique that is capable of on-load creep damage monitoring. A continuous update of component integrity will enable better informed, targeted inspections and outage maintenance providing increased power generation availability. A low-frequency, permanently installed potential drop system has been previously developed and will be the focus of this thesis. The use of a quasi-DC inspection frequency suppresses the influence of the electromagnetic skin effect that would otherwise undermine the stability of the measurement in the ferromagnetic materials of interest; the use of even low frequency measurements allows phase sensitive detection and greatly enhanced noise performance. By permanently installing the electrodes to the surface of the component the resistance measurement is sensitive to strain. A resistance - strain inversion is derived and validated experimentally; the use of the potential drop sensor as a robust, high temperature strain gauge is therefore demonstrated. The strain rate of a component is known to be an expression of the creep state of the component. This concept was adopted to develop an interpretive framework for inferring the creep state of a component. It is possible to monitor the accumulation of creep damage through the symptomatic relative increase in strain rate. By taking the ratio of two orthogonal strain measurements, instability and drift common to both measurements can be effectively eliminated; an important attribute considering the necessity to monitor very low strain rates over decades in time in a harsh environment. A preliminary study of using the potential drop technique for monitoring creep damage at a weld has been conducted. Welds provide a site for preferential creep damage accumulation and therefore will frequently be the life limiting feature of power station components. The potential drop technique will be sensitive to both the localised strain that is understood to act as precursor to creep damage at a weld and also the initiation and growth of a crack. Through the course of this project, two site trials have been conducted in power stations. A measurement system and high temperature hardware that is suitable for the power station environment has been developed. The focus of this thesis is the effective transfer of the technique to industry; the realisation of this is detailed in the final chapter.Open Acces

    DREMUS:A Data-Restricted Multi-Physics Simulation Model for Lithium-Ion Battery Storage

    Get PDF
    This paper presents a modelling approach to support the techno-economic analysis of Li-Ion battery energy storage systems (BESS) for third party organisations considering the purchase or use of BESS but lacking the detailed knowledge of battery operation and degradation. It takes into account the severe data-limitations and provides the best possible approximation for its long-term electrical, thermal and ageing performance. This is achieved by constructing flexible and scalable ageing models from experimental data based on manufacturer's datasheets, warranties and manuals as key inputs. The precision of the individual models has been determined using experimental data and has been found with <8 % normalised root-mean-square deviation (NRMSD) in all cases to be sufficiently accurate. Through linearization methods, this model is able to compare the long-term performance of BESS and quantify the degradative impact of specific charge/discharge mission profiles, which improves the tangibility of BESS as value generating asset

    Real-time power system impedance estimation for DG applications: Using PV-inverter based harmonic injection method

    Get PDF
    On-line power system (PS) Thévenin equivalent impedance (TEI) estimation involves the reduction of the PS's complex circuit into a simple form that provides valuable insight into its state and behaviour. It finds application in numerous areas such as voltage stability monitoring and islanding detection. In the context of distributed generation (DG), on-line TEI estimation can be easily implemented in existing hardware to add functionality and improve the operation of power converters – the key components of DG systems. Two distinct methods of on-line PS TEI estimation exist. The passive method involves only measurement of voltage and current, whereas the active method involves injection of current into the PS and measurement of the response. This work is focused on the active method. Through a review of the available literature, limitations of past work are highlighted. It is shown that the nature of current injection varies greatly in different works and that evaluation of implementation performance is generally not thorough. Little consideration has been made of the effect of injection current level and frequency on the performance of on-line TEI estimation. Furthermore, the behaviour of the grid and its impact has not been thoroughly investigated. In this work, the active method is implemented in a three-phase PV-inverter and thoroughly tested in terms of its TEI estimation accuracy. Dependence of said accuracy on parameters such as the level of injected current and its frequency is shown to be high through tests performed on the live PS at two locations. These parameters are optimised such that TEI accuracy is maximised and the performance of the device is shown to be good compared to calibration equipment. The accuracy of PS TEI tracking is evaluated and quantified. Considerations are also made of the device's hardware limitations and their effect. A process by which a device's TEI estimation accuracy can be thoroughly evaluated is developed through this work. The behaviour of the PS's TEI is also investigated over long periods and characterised. It is found that the TEI remains steady around an average level in both test locations, with a low standard deviation. Consistency in results is found to be high between the two tests

    The design and evaluation of discrete wearable medical devices for vital signs monitoring

    Get PDF
    The observation, recording and appraisal of an individual’s vital signs, namely temperature, heart rate, blood pressure, respiratory rate and blood oxygen saturation (SpO2), are key components in the assessment of their health and wellbeing. Measurements provide valuable diagnostic data, facilitating clinical diagnosis, management and monitoring. Respiratory rate sensing is perhaps the most under-utilised of all the vital signs, being routinely assessed by observation or estimated algorithmically from respiratory-induced beat-to-beat variation in heart rate. Moreover there is an unmet need for wearable devices that can measure all or most of the vital signs. This project therefore aims to a) develop a device that can measure respiratory rate and b) develop a wearable device that can measure all or most of the vital signs. An accelerometer-based clavicular respiratory motion sensor was developed and compared with a similar thoracic motion sensor and reference using exhalatory flow. Pilot study results established that the clavicle sensor accurately tracked the reference in monitoring respiratory rate and outperformed the thoracic device. An Ear-worn Patient Monitoring System (EPMS) was also developed, providing a discrete telemonitoring device capable of rapidly measuring tympanic temperature, heart rate, SpO2 and activity level. The results of a comparative pilot study against reference instruments revealed that heart rate matched the reference for accuracy, while temperature under read (< 1°C) and SpO2 was inconsistent with poor correlation. In conclusion, both of the prototype devices require further development. The respiratory sensor would benefit from product engineering and larger scale testing to fully exploit the technology, but could find use in both hospital and community-based The design and evaluation of discrete wearable medical devices for vital signs monitoring DG Pitts ii Cranfield University monitoring. The EPMS has potential for clinical and community use, having demonstrated its capability of rapidly capturing and wirelessly transmitting vital signs readings. Further development is nevertheless required to improve the thermometer probe and resolve outstanding issues with SpO2 readings
    corecore