158 research outputs found
Miniaturized Microwave Devices and Antennas for Wearable, Implantable and Wireless Applications
This thesis presents a number of microwave devices and antennas that maintain
high operational efficiency and are compact in size at the same time. One goal
of this thesis is to address several miniaturization challenges of antennas and
microwave components by using the theoretical principles of metamaterials,
Metasurface coupling resonators and stacked radiators, in combination with the
elementary antenna and transmission line theory. While innovating novel
solutions, standards and specifications of next generation wireless and
bio-medical applications were considered to ensure advancement in the
respective scientific fields. Compact reconfigurable phase-shifter and a
microwave cross-over based on negative-refractive-index transmission-line
(NRI-TL) materialist unit cells is presented. A Metasurface based wearable
sensor architecture is proposed, containing an electromagnetic band-gap (EBG)
structure backed monopole antenna for off-body communication and a fork shaped
antenna for efficient radiation towards the human body. A fully parametrized
solution for an implantable antenna is proposed using metallic coated stacked
substrate layers. Challenges and possible solutions for off-body, on-body,
through-body and across-body communication have been investigated with an aid
of computationally extensive simulations and experimental verification. Next,
miniaturization and implementation of a UWB antenna along with an analytical
model to predict the resonance is presented. Lastly, several miniaturized
rectifiers designed specifically for efficient wireless power transfer are
proposed, experimentally verified, and discussed. The study answered several
research questions of applied electromagnetic in the field of bio-medicine and
wireless communication.Comment: A thesis submitted for the degree of Ph
Integrated Electronics for Wireless Imaging Microsystems with CMUT Arrays
Integration of transducer arrays with interface electronics in the form of single-chip CMUT-on-CMOS has emerged into the field of medical ultrasound imaging
and is transforming this field. It has already been used in several commercial products such as handheld full-body imagers and it is being implemented by commercial and academic groups for Intravascular Ultrasound and Intracardiac Echocardiography. However, large attenuation of ultrasonic waves transmitted through
the skull has prevented ultrasound imaging of the brain. This research is a prime
step toward implantable wireless microsystems that use ultrasound to image the
brain by bypassing the skull. These microsystems offer autonomous scanning
(beam steering and focusing) of the brain and transferring data out of the brain for
further processing and image reconstruction.
The objective of the presented research is to develop building blocks of an integrated electronics architecture for CMUT based wireless ultrasound imaging systems while providing a fundamental study on interfacing CMUT arrays with their
associated integrated electronics in terms of electrical power transfer and acoustic
reflection which would potentially lead to more efficient and high-performance
systems.
A fully wireless architecture for ultrasound imaging is demonstrated for the
first time. An on-chip programmable transmit (TX) beamformer enables phased
array focusing and steering of ultrasound waves in the transmit mode while its
on-chip bandpass noise shaping digitizer followed by an ultra-wideband (UWB)
uplink transmitter minimizes the effect of path loss on the transmitted image data
out of the brain. A single-chip application-specific integrated circuit (ASIC) is de-
signed to realize the wireless architecture and interface with array elements, each
of which includes a transceiver (TRX) front-end with a high-voltage (HV) pulser,
a high-voltage T/R switch, and a low-noise amplifier (LNA). Novel design techniques are implemented in the system to enhance the performance of its building
blocks.
Apart from imaging capability, the implantable wireless microsystems can include a pressure sensing readout to measure intracranial pressure. To do so, a
power-efficient readout for pressure sensing is presented. It uses pseudo-pseudo
differential readout topology to cut down the static power consumption of the sensor for further power savings in wireless microsystems.
In addition, the effect of matching and electrical termination on CMUT array
elements is explored leading to new interface structures to improve bandwidth
and sensitivity of CMUT arrays in different operation regions. Comprehensive
analysis, modeling, and simulation methodologies are presented for further investigation.Ph.D
Communication and energy delivery architectures for personal medical devices
Thesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Electrical Engineering and Computer Science, 2012.Cataloged from PDF version of thesis.Includes bibliographical references (p. 219-232).Advances in sensor technologies and integrated electronics are revolutionizing how humans access and receive healthcare. However, many envisioned wearable or implantable systems are not deployable in practice due to high energy consumption and anatomically-limited size constraints, necessitating large form-factors for external devices, or eventual surgical re-implantation procedures for in-vivo applications. Since communication and energy-management sub-systems often dominate the power budgets of personal biomedical devices, this thesis explores alternative usecases, system architectures, and circuit solutions to reduce their energy burden. For wearable applications, a system-on-chip is designed that both communicates and delivers power over an eTextiles network. The transmitter and receiver front-ends are at least an order of magnitude more efficient than conventional body-area networks. For implantable applications, two separate systems are proposed that avoid reimplantation requirements. The first system extracts energy from the endocochlear potential, an electrochemical gradient found naturally within the inner-ear of mammals, in order to power a wireless sensor. Since extractable energy levels are limited, novel sensing, communication, and energy management solutions are proposed that leverage duty-cycling to achieve enabling power consumptions that are at least an order of magnitude lower than previous work. Clinical measurements show the first system demonstrated to sustain itself with a mammalian-generated electrochemical potential operating as the only source of energy into the system. The second system leverages the essentially unlimited number of re-charge cycles offered by ultracapacitors. To ease patient usability, a rapid wireless capacitor charging architecture is proposed that employs a multi-tapped secondary inductive coil to provide charging times that are significantly faster than conventional approaches.by Patrick Philip Mercier.Ph.D
Development of miniaturized antennas and adaptive tuning solutions for body sensor network applications
Wireless Sensor Networks (WSNs) are currently having a revolutionary impact in rapidly emerging wearable applications such as health and fitness monitoring amongst many others. These types of Body Sensor Network (BSN) applications require highly integrated wireless sensor devices for use in a wearable configuration, to monitor various physiological parameters of the user. These new requirements are currently posing significant design challenges from an antenna perspective. This work addresses several design challenges relating to antenna design for these types of applications. In this thesis, a review of current antenna solutions for WSN applications is first presented, investigating both commercial and academic solutions. Key design challenges are then identified relating to antenna size and performance. A detailed investigation of the effects of the human body on antenna impedance characteristics is then presented. A first-generation antenna tuning system is then developed. This system enables the antenna impedance to be tuned adaptively in the presence of the human body. Three new antenna designs are also presented. A compact, low-cost 433 MHz antenna design is first reported and the effects of the human body on the impedance of the antenna are investigated. A tunable version of this antenna is then developed, using a higher performance, second-generation tuner that is integrated within the antenna element itself, enabling autonomous tuning in the presence of the human body. Finally, a compact sized, dual-band antenna is reported that covers both the 433 MHz and 2.45 GHz bands to provide improved quality of service (QoS) in WSN applications. To date, state-of-the-art WSN devices are relatively simple in design with limited antenna options available, especially for the lower UHF bands. In addition, current devices have no capability to deal with changing antenna environments such as in wearable BSN applications. This thesis presents several contributions that advance the state-of-the-art in this area, relating to the design of miniaturized WSN antennas and the development of antenna tuning solutions for BSN applications
A Novel Power-Efficient Wireless Multi-channel Recording System for the Telemonitoring of Electroencephalography (EEG)
This research introduces the development of a novel EEG recording system that is modular, batteryless, and wireless (untethered) with the supporting theoretical foundation in wireless communications and related design elements and circuitry. Its modular construct overcomes the EEG scaling problem and makes it easier for reconfiguring the hardware design in terms of the number and placement of electrodes and type of standard EEG system contemplated for use. In this development, portability, lightweight, and applicability to other clinical applications that rely on EEG data are sought. Due to printer tolerance, the 3D printed cap consists of 61 electrode placements. This recording capacity can however extend from 21 (as in the international 10-20 systems) up to 61 EEG channels at sample rates ranging from 250 to 1000 Hz and the transfer of the raw EEG signal using a standard allocated frequency as a data carrier. The main objectives of this dissertation are to (1) eliminate the need for heavy mounted batteries, (2) overcome the requirement for bulky power systems, and (3) avoid the use of data cables to untether the EEG system from the subject for a more practical and less restrictive setting.
Unpredictability and temporal variations of the EEG input make developing a battery-free and cable-free EEG reading device challenging. Professional high-quality and high-resolution analog front ends are required to capture non-stationary EEG signals at microvolt levels. The primary components of the proposed setup are the wireless power transmission unit, which consists of a power amplifier, highly efficient resonant-inductive link, rectification, regulation, and power management units, as well as the analog front end, which consists of an analog to digital converter, pre-amplification unit, filtering unit, host microprocessor, and the wireless communication unit. These must all be compatible with the rest of the system and must use the least amount of power possible while minimizing the presence of noise and the attenuation of the recorded signal
A highly efficient resonant-inductive coupling link is developed to decrease power transmission dissipation. Magnetized materials were utilized to steer electromagnetic flux and decrease route and medium loss while transmitting the required energy with low dissipation. Signal pre-amplification is handled by the front-end active electrodes. Standard bio-amplifier design approaches are combined to accomplish this purpose, and a thorough investigation of the optimum ADC, microcontroller, and transceiver units has been carried out. We can minimize overall system weight and power consumption by employing battery-less and cable-free EEG readout system designs, consequently giving patients more comfort and freedom of movement. Similarly, the solutions are designed to match the performance of medical-grade equipment. The captured electrical impulses using the proposed setup can be stored for various uses, including classification, prediction, 3D source localization, and for monitoring and diagnosing different brain disorders.
All the proposed designs and supporting mathematical derivations were validated through empirical and software-simulated experiments. Many of the proposed designs, including the 3D head cap, the wireless power transmission unit, and the pre-amplification unit, are already fabricated, and the schematic circuits and simulation results were based on Spice, Altium, and high-frequency structure simulator (HFSS) software. The fully integrated head cap to be fabricated would require embedding the active electrodes into the 3D headset and applying current technological advances to miniaturize some of the design elements developed in this dissertation
Recommended from our members
Microwave Front-End Component Codesign: Filter-Amplifiers, Integrated Passives and Rectifying-Radiators
The ever-growing need for improved wireless communications motivates innovation in miniaturization and integration of microwave front-end components. This thesis addresses miniaturization by co-design methods that enable simultaneous size reduction, improved efficiency, diverse technology integration, and enhanced safety. First, a new theoretical treatment for simple design of narrowband filters with arbitrary complex impedance ports is introduced and validated through 2.4GHz designs with 2nd-order all-pole and 4th-order elliptical response. The theory is then extended to filters with port impedance tuning capabilities and validated with a 2nd-order Chebyshev filter with varactor-tunable input impedance over a pre-defined impedance range with maintained filter response. The theory is also applied to impedance-matching filters for power amplifiers (PAs) with the goal of improving efficiency and reducing footprint. A high-efficiency 4.7GHz single-stage 4-W hybrid GaN filter-PA (FPA) shows a measured gain of 15dB and PAE=55% with a pre-specified 9% fractional bandwidth. The approach is further validated on a GaAs MMIC FPA at 28GHz with a measured saturated gain of 8dB, 200mW of output power and PAE=30%.
For further integration of components with miniaturized footprint, a heterogeneous integration process called metal-embedded chip assembly (MECA), developed by HRL, is exploited to combine ceramic passive circuits, surface-mount capacitors and GaN MMICs with a unique interconnect network. The interconnects outperform standard wirebonds and are also used to implement transmission lines, referred to as bridge-lines, with reduced loss and higher possible characteristic impedances compared to microstrip. Various couplers in the 8-10GHz range are designed and characterized to demonstrate the additional design capabilities provided by the MECA process. Thermal performance improvement of PAs is shown, and increased gain and efficiency for an X-band GaN MMIC is reported. Finally, the FPA design approach from the first part of the thesis is used to design a quasi-MMIC FPA with a predicted gain of 7.4dB, peak PAE of 23% and output power above 30dBm from 23.65 to 24.4GHz. Additionally, a 20-GHz dual-mode rectangular cavity resonator filter with insertion loss under 0.25dB is designed in the MECA process, and is in fabrication at the time of writing of this thesis.
Wireless systems rely on batteries or wired charging, which limits the operational time. In the second part of the thesis, co-design and integration of wireless charging and harvesting is researched. Another application of wireless charging is for electric vehicles, where methods analogous to microwave antenna arrays, amplifiers and rectifiers can be used to provide a means for charging batteries of stationary or moving vehicles at lower frequencies and high power levels. A new method for reducing fringing fields in a capacitive wireless power transfer (CWPT) system using a near-field phased array is demonstrated using a multi-module approach on a 1.1kW system at 13.67MHz at a 25-cm energy-transfer distance with over 80% efficiency. To meet safety standards, a fringing field reduction of 24% with a two-module system and 43% with a four-module system, is demonstrated at 7, 14 and 29MHz. This system applied co-design of capacitor arrays with matching networks for the high-power inverters and rectifiers on the circuit side, and energy-transfer and fringing fields on the free-space side.
In the low-power regime, co-design of both narrowband and broadband rectifiers and antennas for harvesting ambient power for wireless devices is demonstrated.Harvesting power from airplane altimeter radar antenna sidebands with a rectifier-antenna (rectenna) for aircraft health monitoring sensors demonstrates the possibility of charging a storage device at incident power levels below 2 W/cm2 at 4.3GHz. The narrowband harvesting device applies co-design to the antenna, rectifier and maximum power point tracking power-management circuit to provide a usable voltage level. For wideband energy harvesting from unknown and variable sources, wearable rectenna arrays screen-printed on clothing are demonstrated for harvesting 4-130W/cm2 power densities over more than an octave bandwidth in the sub-6GHz frequency range. Measurements on 36 and 64-element arrays show up to PDC=32W for incident power densities of 4W/cm2. For low incident power densities, the efficiency is in the 5-10% range, and reaches 32% for 100W/cm2. In these arrays, the rectifiers and tightly-coupled antennas are co-designed for broadband performance.</p
Antenna sensing for wearable applications
As wearable technologies are growing fast, there is emerging trend to increase functionality of the devices. Antennas which are primarily component in communication systems can offer attractive route forward to minimize the number of components functioning as a sensing element for wearable and flexible electronics. Toward development of flexible antenna as sensing element, this thesis investigates the development of the flexible and printed sensing NFC RFID tag. In this approach, the sensor measurement is supported by the internal sensor and analog-to-digital convertor (ADC) of the NFC transponder. Design optimisation, fabrication and characterization of the printed antenna are described. Besides, the printed antenna, NFC transponder and two simple resistive sensors are integrated to form a fully flexible sensing RFID tag demonstrating applicability in food and health monitoring.
This thesis also presents development of two antenna sensors by using functional materials: (i) An inductor-capacitor (LC) resonant tank based wireless pressure sensor on electrospun Poly-L-lactide (PLLA) nanofibers-based substrate. The screen-printed resonant tank (resonant frequency of ~13.56 MHz) consists of a planar inductor connected in parallel with an interdigitated capacitor. Since the substrates is piezoelectric, the capacitance of the interdigitated capacitor varies in response to the applied pressure. To demonstrate a potential application of developed pressure sensor, it was integrated on a compression bandage to monitor sub-bandage pressure. (ii) To investigate the realization of sensing antenna as temperature sensor simple loop antenna is designed and in this study unlike the first study that the sensing element was the substrate, the conductive body of the antenna itself is considered as a functional material. In this case, a small part of a loop antenna which originally was printed using silver paste is replaced by Poly(3,4-ethylenedioxythiophene): polystyrene (PEDOT: PSS). The sensing mechanism is based on the resonant frequency shift by varying temperature.
While using functional materials is useful for realization of antenna sensor, another approach also is presented by developing stretchable textile-based microstrip antennas on deformable substrate which can measure joint angles of a human limb. The EM characteristics of the meshed patch antenna were compared with its metallic counterpart fabricated with lithography technique. Moreover, the concept of stretchable UHF RFID-based strain sensor is touched in the final part of this thesis
Developing Biosensor Technology to Monitor Biofilm Formation on Voice Prosthesis in Throat Cancer Patients Following Total Laryngectomy
Voice prostheses (used to replace an excised larynx in laryngectomy patients) are often colonised by the yeast Candida albicans, yet no monitoring technology for C. albicans biofilm growth until these devices fail. With the current interest in smart technology, understanding the electrical properties of C. albicans biofilm formation is necessary. There has been great interest in Passive Radio Frequency Identification (RFID) for use with implantable devices as they provide a cost-effective approach for sensing. The main drawback of RFID sensors is the need to overcome capacitive loading of human tissue and, thus, low efficiency to produce a high read range sensor design. This is further complicated by the size restriction on any RFID design to be implemented within a voice prosthesis as this medical device is limited to less than 3 cm in overall size. In order to develop such a voice prosthesis sensor, we looked at three separate aspects of C. albicans colonisation on medical devices within human tissue. To understand if it is possible to detect changes within a moist environment (such as the mouth), we developed a sensor capable of detecting minute dielectric changes (accuracy of ± 0.83 relative permittivity and ± 0.05 S·m-1 conductivity) within a closed system. Once we understood that detection of dielectric changes within a liquid solution were possible, to overcome human tissue capacitive loading of RFID sensors. Adjusting backing thickness or adding a capacitive shunt into the design could limit this tissue effect and even negate the variability seen between human tissues. Without developing these methods, implementation of any RFID device would be difficult as human tissue variability would not be compensated for properly. Finally, biofilm growth in terms electrical properties. As C. albicans biofilm matures, there is a loss in capacitance (the biofilm becomes increasingly hydrophobic) prior to 24 hours after which the biofilm thickness shifts the resonance leading to a slow gain in capacitance. Understanding all of these aspects allowed us to develop two final voice prosthesis sensors producing read ranges above 60 cm and 10 cm within a tissue phantom. Ultimately, this showed the possibility of developing cost-effective passive RFID sensor technology for monitoring microbial biofilm formation within human tissue, leading to more effective real-time clinical care
Integrated Circuits and Systems for Smart Sensory Applications
Connected intelligent sensing reshapes our society by empowering people with increasing new ways of mutual interactions. As integration technologies keep their scaling roadmap, the horizon of sensory applications is rapidly widening, thanks to myriad light-weight low-power or, in same cases even self-powered, smart devices with high-connectivity capabilities. CMOS integrated circuits technology is the best candidate to supply the required smartness and to pioneer these emerging sensory systems. As a result, new challenges are arising around the design of these integrated circuits and systems for sensory applications in terms of low-power edge computing, power management strategies, low-range wireless communications, integration with sensing devices. In this Special Issue recent advances in application-specific integrated circuits (ASIC) and systems for smart sensory applications in the following five emerging topics: (I) dedicated short-range communications transceivers; (II) digital smart sensors, (III) implantable neural interfaces, (IV) Power Management Strategies in wireless sensor nodes and (V) neuromorphic hardware
Analysis of Wireless Body-Centric Medical Sensors for Remote Healthcare
Aquesta tesi aborda el problema de trobar solucions confortables, de baixa potència i sense fils per aplicacions mèdiques. La tesi tracta els avantatges i les limitacions de tres tecnologies de comunicació diferents per la mesura de parà metres del cos i mètodes per redissenyar sensors per avaluacions òptimes centrades en el cos. La tecnologia RFID es considera una de les solucions més influents per superar el problema del consum d'energia limitat, a causa de la presència de molts sensors connectats. També s'ha estudiat la tecnologia Bluetooth de baixa energia per resoldre els problemes de seguretat i la distà ncia de lectura que, en general, representen el coll d'ampolla de RFID pels sensors de cos. Els dispositius analògics poden reduir drà sticament les necessitats d'energia a causa dels sensors i les comunicacions, considerant pocs elements i un mètode de transmissió simple. S'estudia un mètode de comunicació completament passiu, basat en FSS, que permet una distà ncia de lectura raonable amb capacitats de detecció precises i confiables, que s'ha discutit en aquesta tesi. L'objectiu d'aquesta tesi és investigar múltiples tecnologies sense fils per dispositius portà tils per identificar solucions adequades per aplicacions particulars en el camp mèdic. El primer objectiu és demostrar la facilitat d'ús de les tecnologies econòmiques sense bateria com un indicador útil de parà metres fisiopatològics mitjançant la investigació de les propietats de les etiquetes RFID. A més a més, s'ha abordat un aspecte més complex respecte a l'ús de petits components passius com sensors sense fils per trastorns del son. Per últim, un altre objectiu de la tesi és el desenvolupament d'un sistema completament autònom que utilitzi tecnologia BLE per obtenir propietats avançades mantenint baix tant el consum com el preuEsta tesis aborda el problema de encontrar soluciones confortables, inalámbricas y de baja potencia para aplicaciones médicas. La tesis discute las ventajas y limitaciones de tres tecnologÃas de comunicación diferentes para la medición en el cuerpo y los métodos para elegir y remodelar los sensores para evaluaciones óptimas centradas en el cuerpo. La tecnologÃa RFID se considera una de las soluciones más influyentes para superar el consumo de energÃa limitado debido a la presencia de muchos sensores conectados. Además, la baja energÃa de Bluetooth se ha estudiado se ha estudiado la tecnologia Bluetooth de baja energia para resolver los problemas de seguridad y la distancia de lectura que, en general, representan el cuello de botella de la RFID para los sensores de cuerpo. Los dispositivos analógicos pueden reducir drásticamente las necesidades de energÃa debido a los sensores y las comunicaciones, considerando pocos elementos y un método de transmisión simple. Se estudia un método de comunicación completamente pasivo, basado en FSS, que permite una distancia de lectura razonable con capacidades de detección precisas y confiables, que se ha discutido en esta tesis. El objetivo de esta tesis es investigar múltiples tecnologÃas inalámbricas para dispositivos portátiles para identificar soluciones adecuadas para aplicaciones particulares en campos médicos. El primer objetivo es demostrar la facilidad de uso de las tecnologÃas económicas sin baterÃa como un indicador útil de dichos parámetros fisiopatológicos mediante la investigación de las propiedades de las etiquetas RFID. Además, se ha abordado un aspecto más complejo con respecto al uso de pequeños componentes pasivos como sensores inalámbricos para enfermedades del sueño. Por último, un resultado de la tesis es desarrollar un sistema completamente autónomo que utilice la tecnologÃa BLE para obtener propiedades avanzadas que mantengan la baja potencia y un precio bajo.This thesis addresses the problem of comfortable, low powered and, wireless solutions for specific body-worn sensing. The thesis discusses advantages and limitations of three different communication technologies for on body measurement and investigate methods to reshape sensors for optimum body-centric assessments. The RFID technology is considered one of the most influential solutions to overcome the limitated power consumption due to the presence of many sensors connected. Further, the Bluetooth low energy has been studied to solve security problems and reading distance that overall represent the bottleneck of the RFID for the body-worn sensors. Analog devices can drastically reduce the energy needs due to the sensors and the communications, considering few elements and a simple transmitting method. An entirely passive communication method, based on FSS is studied, enabling a reasonable reading distance with precise and reliable sensing capabilities, which has been discussed in this thesis. The objective of this thesis is to investigate multiple wireless technologies for wearable devices to identify suitable solutions for particular applications in medical fields. The first objective is to demonstrate the usability of the inexpensive battery-less technologies as a useful indicator of such a physio-pathological parameters by investigating the properties of the RFID tags. Furthermore, a more complex aspect regards the use of small passive components as wireless sensors for sleep diseases has been addressed. Lastly, an outcome of the thesis is to develop an entirely autonomous system using the BLE technology to obtain advanced properties keeping low power and a low price
- …