64 research outputs found

    Detection and Processing Techniques of FECG Signal for Fetal Monitoring

    Get PDF
    Fetal electrocardiogram (FECG) signal contains potentially precise information that could assist clinicians in making more appropriate and timely decisions during labor. The ultimate reason for the interest in FECG signal analysis is in clinical diagnosis and biomedical applications. The extraction and detection of the FECG signal from composite abdominal signals with powerful and advance methodologies are becoming very important requirements in fetal monitoring. The purpose of this review paper is to illustrate the various methodologies and developed algorithms on FECG signal detection and analysis to provide efficient and effective ways of understanding the FECG signal and its nature for fetal monitoring. A comparative study has been carried out to show the performance and accuracy of various methods of FECG signal analysis for fetal monitoring. Finally, this paper further focused some of the hardware implementations using electrical signals for monitoring the fetal heart rate. This paper opens up a passage for researchers, physicians, and end users to advocate an excellent understanding of FECG signal and its analysis procedures for fetal heart rate monitoring system

    Non-invasive Detection and Compression of Fetal Electrocardiogram

    Get PDF
    Noninvasive detection of fetal electrocardiogram (FECG) from abdominal ECG recordings is highly dependent on typical statistical signal processing techniques such as independent component analysis (ICA), adaptive noise filtering, and multichannel blind deconvolution. In contrast to the previous multichannel FECG extraction methods, several recent schemes for single‐channel FECG extraction such as the extended Kalman filter (EKF), extended Kalman smoother (EKS), template subtraction (TS), and support vector regression (SVR) for detecting R waves on ECG, are evaluated via the quantitative metrics such as sensitivity (SE), positive predictive value (PPV), F‐score, detection error rate (DER), and range of accuracy. A correlation predictor that combines with multivariable gray model (GM) is also proposed for sequential ECG data compression, which displays better percent root mean-square difference (PRD) than those of Sabah’s scheme for fixed and predicted compression ratio (CR). Automatic calculation on fetal heart rate (FHR) on the reconstructed FECG from mixed signals of abdominal ECG recordings is also experimented with sample synthetic ECG data. Sample data on FHR and T/QRS for both physiological case and pathological case are simulated in a 10-min time sequence

    Advances in Digital Processing of Low-Amplitude Components of Electrocardiosignals

    Get PDF
    This manual has been published within the framework of the BME-ENA project under the responsibility of National Technical University of Ukraine. The BME-ENA “Biomedical Engineering Education Tempus Initiative in Eastern Neighbouring Area”, Project Number: 543904-TEMPUS-1-2013-1-GR-TEMPUS-JPCR is a Joint Project within the TEMPUS IV program. This project has been funded with support from the European Commission.Навчальний посібник присвячено розробці методів та засобів для неінвазивного виявлення та дослідження тонких проявів електричної активності серця. Особлива увага приділяється вдосконаленню інформаційного та алгоритмічного забезпечення систем електрокардіографії високого розрізнення для ранньої діагностики електричної нестабільності міокарда, а також для оцінки функціонального стану плоду під час вагітності. Теоретичні основи супроводжуються прикладами реалізації алгоритмів за допомогою системи MATLAB. Навчальний посібник призначений для студентів, аспірантів, а також фахівців у галузі біомедичної електроніки та медичних працівників.The teaching book is devoted to development and research of methods and tools for non-invasive detection of subtle manifistations of heart electrical activity. Particular attention is paid to the improvement of information and algorithmic support of high resolution electrocardiography for early diagnosis of myocardial electrical instability, as well as for the evaluation of the functional state of the fetus during pregnancy examination. The theoretical basis accompanied by the examples of implementation of the discussed algorithms with the help of MATLAB. The teaching book is intended for students, graduate students, as well as specialists in the field of biomedical electronics and medical professionals

    Fetal autonomic cardiac response during pregnancy and labour

    Get PDF
    Timely recognition of fetal distress, during pregnancy and labour, in order to intervene adequately is of major importance to avoid neonatal morbidity and mortality. As discussed in chapter 1, the cardiotocogram (CTG) might be a useful screening test for fetal monitoring but it has insufficient specificity and requires additional diagnostic tests in case of suspected fetal compromise to avoid unnecessary operative deliveries. Potential additional techniques used in clinical practice are fetal scalp blood sampling (FBS) and ST-waveform analysis of the fetal electrocardiogram (ECG; STAN®). However, publications on these techniques provide limited support for the use of these methods in the presence of a non-reassuring CTG for reducing caesarean sections. In addition, these techniques are invasive and can therefore only be used during labour at the term or the near term period. Consequently, it is of great clinical importance that additional methods are developed that contribute to more reliable assessment of fetal condition. Preferably, this information is obtained non-invasively. Valuable additional information on the fetal condition can possibly be obtained by spectral analysis of fetal heart rate variability (HRV). The fetal heart rate fluctuates under the control of the autonomic part of the central nervous system. The autonomic cardiac modulation is discussed in chapter 2. The sympathetic and parasympathetic nervous systems typically operate on partly different timescales. Time-frequency analysis (spectral analysis) of fetal beat-to-beat HRV can hence quantify sympathetic and parasympathetic modulation and characterise autonomic cardiac control . The low frequency (LF) component of HRV is associated with both sympathetic and parasympathetic modulation while the high frequency (HF) component is associated with parasympathetic modulation alone2. Spectral estimates of HRV might indirectly reflect fetal wellbeing and increase insight in the human fetal autonomic cardiac response. In chapter 3, technical details for retrieving fetal beat-to-beat heart rate and its spectral estimates are provided. In this thesis spectral analysis of fetal HRV is investigated. The first objective is to study the value of spectral analysis of fetal HRV as a tool to assess fetal wellbeing during labour at term. The second objective is to monitor spectral estimates of fetal HRV, non-invasively, during gestation to increase insight in the development of human fetal autonomic cardiac control. Since Akselrod reported the relation between autonomic nervous system modulation and LF and HF peaks in frequency domain1, frequency analysis of RR interval fluctuations is widely performed . For human adults, standards for HRV measurement and physiological interpretation have been developed2. Although HRV parameters are reported to be highly prognostic in human adults in case of cardiac disease, little research is done towards the value of these parameters in assessing fetal distress in the human fetus, as shown in chapter 4. In this chapter, the literature about time-frequency analysis of human fetal HRV is reviewed in order to determine the value of spectral estimates for fetal surveillance. Articles that described spectral analysis of human fetal HRV and compared the energy in spectral bands with fetal bloodgas values were included. Only six studies met our inclusion criteria. One study found an initial increase in LF power during the first stage of fetal compromise, which was thought to point to stress-induced sympathetic hyperactivity3. Five out of six studies showed a decrease in LF power in case of fetal distress , , , , ,. This decrease in LF power in case of severe fetal compromise was thought to be the result of immaturity or decompensation of the fetal autonomic nervous system. These findings support the hypothesis that spectral analysis of fetal HRV might be a promising method for fetal surveillance. All studies included in the literature review used absolute values of LF and HF power. Although absolute LF and HF power of HRV provide useful information on autonomic modulation, especially when considering fetal autonomic development, LF and HF power may also be measured in normalised units. Normalised LF (LFn) and normalised HF power (HFn) of HRV represent the relative value of each power component in proportion to the total power2. Adrenergic stimulation can cause a sympathetically-modulated increase in fetal heart rate . A negative correlation however exists between heart rate and HRV . As a result, the sympathetic stimulation can decrease the total power of HRV and even the absolute LF power. When normalising the absolute LF (and HF) with respect to the total power, a shift in activity from HFn to LFn might become visible, revealing the expected underlying sympathetic activity. Thus, because changes in total power influence absolute spectral estimates in the same direction, normalised values of LF and HF power seem more suitable for fetal monitoring. In other words, normalised spectral estimates detect relative changes that are no longer masked by changes in total power2. LFn and HFn power are calculated by dividing LF and HF power, respectively, by total power and represent the controlled and balanced behaviour of the two branches of the autonomic nervous system2. In chapter 5 we hypothesised that the autonomic cardiovascular control is functional in fetuses at term, and that LFn power increases in case of distress due to increased sympathetic modulation. During labour at term, ten acidaemic fetuses were compared with ten healthy fetuses. During the last 30 minutes of labour, acidaemic fetuses had significantly higher LFn power and lower HFn power than control fetuses, which points to increased sympathetic modulation. No differences in absolute LF or HF power were found between both groups. The observed differences in normalised spectral estimates of HRV were not observed earlier in labour. In conclusion, it seems that the autonomic nervous system of human fetuses at term responds adequately to severe stress during labour. Normalised spectral estimates of HRV might be able to discriminate between normal and abnormal fetal condition. Although we found significant differences in normalised spectral estimates between healthy and acidaemic fetuses, we wondered whether spectral power of HRV is also related to fetal distress in an earlier stage. The next step in chapter 6 was therefore, to investigate whether spectral estimates are related to fetal scalp blood pH during labour. Term fetuses during labour, in cephalic presentation, that underwent one or more scalp blood samples were studied. Beat-to-beat fetal heart rate segments, preceding the scalp blood measurement, were used to calculate spectral estimates. In total 39 FBS from 30 patients were studied. We found that normalised spectral estimates are related to fetal scalp blood pH while absolute spectral estimates are not related to fetal pH. It was further demonstrated that LFn power is negatively related and HFn power is positively related to fetal pH. These findings point to increased sympathetic and decreased parasympathetic cardiac modulation in human fetuses at term upon decrease of their pH value. This study confirms the hypothesis that normalised spectral values of fetal HRV are related to fetal distress in an early stage. Previous studies showed that absolute LF and HF power increase as pregnancy progresses, which is attributed to fetal autonomic maturation , . Since it is yet unclear how LFn and HFn evolve with progressing pregnancy, before using spectral analysis for fetal monitoring, it has to be determined whether gestational age has to be corrected for. In addition, fetal autonomic fluctuations, and thus spectral estimates of HRV, are influenced by fetal behavioural state . Since these states continue to change during labour , thorough understanding of the way in which these changes in state influence spectral power is necessary for the interpretation of spectral values during labour at term. Therefore, in chapter 7, we examined whether differences in spectral estimates exist between healthy near term and post term fetuses during labour. In case such differences do exist, they should be taken into consideration for fetal monitoring. The quiet and active sleep states were studied separately to determine the influence of fetal behavioural state on spectral estimates of HRV during labour around term. No significant differences in spectral estimates were found between near term and post term fetuses during active sleep. During quiet sleep, LFn power was lower and HF and HFn power were higher in post term compared to near term fetuses, no significant differences in LF power were observed between both groups. LF, HF and LFn power were higher and HFn power was lower during active sleep compared to quiet sleep in both groups. This seems to point to sympathetic predominance during the active state in fetuses around term. In addition, post term parasympathetic modulation during rest seems increased compared to near term. In conclusion, fetal behavioural state and gestational age cause a considerable variability in spectral estimates in fetuses during labour, around term, which should be taken into consideration when using spectral estimates for fetal monitoring. In chapters 4 to 6, spectral estimates of beat-to-beat fetal HRV were studied using fetal ECG recordings that were obtained directly from the fetal scalp during labour. However, the second objective of this thesis is to obtain spectral estimates non-invasively during gestation to increase insight in the development of human fetal autonomic cardiac control. The fetal ECG is also present on the maternal abdomen, although much smaller in amplitude and obscured by the maternal ECG and noise. Chapter 8 focused on non-invasive measurement of the fetal ECG from the maternal abdomen. These measurements allow for obtaining beat-to-beat fetal heart rate non-invasively. Therefore, this method can be used to obtain spectral estimates of fetal HRV throughout gestation. Although abdominal recording of the fetal ECG may offer valuable additional information, it is troubled by poor signal-to-noise ratios (SNR) during certain parts of pregnancy, e.g. during the immature period and during the vernix period. To increase the usability of abdominal fetal ECG recordings, an algorithm was developed that uses a priori knowledge on the physiology of the fetal heart to enhance the fetal ECG components in multi-lead abdominal fetal ECG recordings, before QRS-detection. Evaluation of the method on generated fetal ECG recordings with controlled SNR showed excellent results. The method for non-invasive fetal ECG and beat-to-beat heart rate detection presented in chapter 8 was used for analysis in chapter 9. The feasibility of this method in a longitudinal patient study was investigated. In addition, changes in spectral estimates of HRV during pregnancy were studied and related to fetal rest-activity state to study the development of fetal autonomic cardiac control. We found that approximately 3% of non-invasive fetal ECG recordings could be used for spectral analysis. Therefore, improvement of both equipment and algorithms is still needed to obtain more good-quality data. The percentage of successfully retrieved data depends on gestational age. Before 18 and between 30 and 34 weeks no good-quality beat-to-beat heart rate data were available. We found an increase in LF and HF power of fetal HRV with increasing gestational age, between 21 to 30 weeks of gestation. This increase in LF and HF power is probably due to increased sympathetic and parasympathetic modulation and might be a sign of autonomic development. Furthermore, we found sympathetic predominance during the active state compared to the quiet state in near term fetuses (34 to 41 weeks of gestation), comparable to the results observed during labour around term. During 34 to 41 weeks a (non-significant) decrease in LF and LFn power and a (non-significant) increase in HF and HFn power were observed. These non-significant changes in spectral estimates in near term fetuses might be associated with changes in fetal rest-activity state and increased parasympathetic modulation as pregnancy progresses. However, more research is needed to confirm this

    Alterations in Maternal–Fetal Heart Rate Coupling Strength and Directions in Abnormal Fetuses

    Get PDF
    Because fetal gas exchange takes place via the maternal placenta, there has been growing interests in investigating the patterns and directions of maternal-fetal cardiac coupling to better understand the mechanisms of placental gas transfer. We recently reported the evidence of short-term maternal–fetal cardiac couplings in normal fetuses by using Normalized Short Time Partial Directed Coherence (NSTPDC) technique. Our results have shown weakening of coupling from fetal heart rate to maternal heart rate as the fetal development progresses while the influence from maternal to fetal heart rate coupling behaves oppositely as it shows increasing coupling strength that reaches its maximum at mid gestation. The aim of this study is to test if maternal-fetal coupling patterns change in various types of abnormal cases of pregnancies. We applied NSTPDC on simultaneously recorded fetal and maternal beat-by-beat heart rates collected from fetal and maternal ECG signals of 66 normal and 19 abnormal pregnancies. NSTPDC fetal-to-maternal coupling analyses revealed significant differences between the normal and abnormal cases (normal: normalized factor (NF) = −0.21 ± 0.85, fetus-to-mother coupling area (A_fBBI→ mBBI) = 0.44 ± 0.13, mother-to-fetus coupling area (A_mBBI→ fBBI) = 0.46 ± 0.12; abnormal: NF = −1.66 ± 0.77, A_fBBI→ mBBI = 0.08 ± 0.12, A_mBBI→ fBBI = 0.66 ± 0.24; p < 0.01). In conclusion, maternal-fetal cardiac coupling strength and direction and their associations with regulatory mechanisms (patterns) of developing autonomic nervous system function could be novel clinical markers of healthy prenatal development and its deviation. However, further research is required on larger samples of abnormal cases

    Non-invasive procedure for fetal electrocardiography

    Full text link
    Antenatal fetal surveillance is a field of increasing importance in modern obstetrics. Measurements extracted (such as fetal heart rate) from antenatal fetal monitoring techniques have the potential to reduce the social, personal and financial burdens of fetal death on families, health care systems and the community. Techniques to monitor the fetus through pregnancy have been developed with the aim of providing information to enable the clinician to diagnose fetal wellbeing, characterise development and detect abnormality. An early diagnosis before delivery may increase the effectiveness of the appropriate treatment. Over the years, various research efforts have been carried out in the field of fetal electrocardiography by attaching surface electrodes to the maternal body. Unfortunately the desired fetal heartbeat signals at the electrode output are buried in an additive mixture of undesired interference disturbances. In this thesis, a non-invasive fetal electrocardiogram machine has been designed, constructed and implemented. This machine is composed of three modified electrocardiogram circuits and an external soundcard. Data was acquired from four surface electrodes placed on the maternal body. Eleven pregnant subjects, with a gestation age between the 30th and 40th weeks of pregnancy, were used to investigate the validity of this machine. Fetal R-waves were detected in 72.7 percent of subjects. The development of a non-invasive machine, capable of detecting and recording valuable anatomic and electrophysiological information of a fetus, represents an important tool in clinical and investigative obstetrics

    Non-invasive fetal electrocardiogram : analysis and interpretation

    Get PDF
    High-risk pregnancies are becoming more and more prevalent because of the progressively higher age at which women get pregnant. Nowadays about twenty percent of all pregnancies are complicated to some degree, for instance because of preterm delivery, fetal oxygen deficiency, fetal growth restriction, or hypertension. Early detection of these complications is critical to permit timely medical intervention, but is hampered by strong limitations of existing monitoring technology. This technology is either only applicable in hospital settings, is obtrusive, or is incapable of providing, in a robust way, reliable information for diagnosis of the well-being of the fetus. The most prominent method for monitoring of the fetal health condition is monitoring of heart rate variability in response to activity of the uterus (cardiotocography; CTG). Generally, in obstetrical practice, the heart rate is determined in either of two ways: unobtrusively with a (Doppler) ultrasound probe on the maternal abdomen, or obtrusively with an invasive electrode fixed onto the fetal scalp. The first method is relatively inaccurate but is non-invasive and applicable in all stages of pregnancy. The latter method is far more accurate but can only be applied following rupture of the membranes and sufficient dilatation, restricting its applicability to only the very last phase of pregnancy. Besides these accuracy and applicability issues, the use of CTG in obstetrical practice also has another limitation: despite its high sensitivity, the specificity of CTG is relatively low. This means that in most cases of fetal distress the CTG reveals specific patterns of heart rate variability, but that these specific patterns can also be encountered for healthy fetuses, complicating accurate diagnosis of the fetal condition. Hence, a prerequisite for preventing unnecessary interventions that are based on CTG alone, is the inclusion of additional information in diagnostics. Monitoring of the fetal electrocardiogram (ECG), as a supplement of CTG, has been demonstrated to have added value for monitoring of the fetal health condition. Unfortunately the application of the fetal ECG in obstetrical diagnostics is limited because at present the fetal ECG can only be measured reliably by means of an invasive scalp electrode. To overcome this limited applicability, many attempts have been made to record the fetal ECG non-invasively from the maternal abdomen, but these attempts have not yet led to approaches that permit widespread clinical application. One key difficulty is that the signal to noise ratio (SNR) of the transabdominal ECG recordings is relatively low. Perhaps even more importantly, the abdominal ECG recordings yield ECG signals for which the morphology depends strongly on the orientation of the fetus within the maternal uterus. Accordingly, for any fetal orientation, the ECG morphology is different. This renders correct clinical interpretation of the recorded ECG signals complicated, if not impossible. This thesis aims to address these difficulties and to provide new contributions on the clinical interpretation of the fetal ECG. At first the SNR of the recorded signals is enhanced through a series of signal processing steps that exploit specific and a priori known properties of the fetal ECG. More particularly, the dominant interference (i.e. the maternal ECG) is suppressed by exploiting the absence of temporal correlation between the maternal and fetal ECG. In this suppression, the maternal ECG complex is dynamically segmented into individual ECG waves and each of these waves is estimated through averaging corresponding waves from preceding ECG complexes. The maternal ECG template generated by combining the estimated waves is subsequently subtracted from the original signal to yield a non-invasive recording in which the maternal ECG has been suppressed. This suppression method is demonstrated to be more accurate than existing methods. Other interferences and noise are (partly) suppressed by exploiting the quasiperiodicity of the fetal ECG through averaging consecutive ECG complexes or by exploiting the spatial correlation of the ECG. The averaging of several consecutive ECG complexes, synchronized on their QRS complex, enhances the SNR of the ECG but also can suppress morphological variations in the ECG that are clinically relevant. The number of ECG complexes included in the average hence constitutes a trade-off between SNR enhancement on the one hand and loss of morphological variability on the other hand. To relax this trade-off, in this thesis a method is presented that can adaptively estimate the number of ECG complexes included in the average. In cases of morphological variations, this number is decreased ensuring that the variations are not suppressed. In cases of no morphological variability, this number is increased to ensure adequate SNR enhancement. The further suppression of noise by exploiting the spatial correlation of the ECG is based on the fact that all ECG signals recorded at several locations on the maternal abdomen originate from the same electrical source, namely the fetal heart. The electrical activity of the fetal heart at any point in time can be modeled as a single electrical field vector with stationary origin. This vector varies in both amplitude and orientation in three-dimensional space during the cardiac cycle and the time-path described by this vector is referred to as the fetal vectorcardiogram (VCG). In this model, the abdominal ECG constitutes the projection of the VCG onto the vector that describes the position of the abdominal electrode with respect to a reference electrode. This means that when the VCG is known, any desired ECG signal can be calculated. Equivalently, this also means that when enough ECG signals (i.e. at least three independent signals) are known, the VCG can be calculated. By using more than three ECG signals for the calculation of the VCG, redundancy in the ECG signals can be exploited for added noise suppression. Unfortunately, when calculating the fetal VCG from the ECG signals recorded from the maternal abdomen, the distance between the fetal heart and the electrodes is not the same for each electrode. Because the amplitude of the ECG signals decreases with propagation to the abdominal surface, these different distances yield a specific, unknown attenuation for each ECG signal. Existing methods for estimating the VCG operate with a fixed linear combination of the ECG signals and, hence, cannot account for variations in signal attenuation. To overcome this problem and be able to account for fetal movement, in this thesis a method is presented that estimates both the VCG and, to some extent, also the signal attenuation. This is done by determining for which VCG and signal attenuation the joint probability over both these variables is maximal given the observed ECG signals. The underlying joint probability distribution is determined by assuming the ECG signals to originate from scaled VCG projections and additive noise. With this method, a VCG, tailored to each specific patient, is determined. With respect to the fixed linear combinations, the presented method performs significantly better in the accurate estimation of the VCG. Besides describing the electrical activity of the fetal heart in three dimensions, the fetal VCG also provides a framework to account for the fetal orientation in the uterus. This framework enables the detection of the fetal orientation over time and allows for rotating the fetal VCG towards a prescribed orientation. From the normalized fetal VCG obtained in this manner, standardized ECG signals can be calculated, facilitating correct clinical interpretation of the non-invasive fetal ECG signals. The potential of the presented approach (i.e. the combination of all methods described above) is illustrated for three different clinical cases. In the first case, the fetal ECG is analyzed to demonstrate that the electrical behavior of the fetal heart differs significantly from the adult heart. In fact, this difference is so substantial that diagnostics based on the fetal ECG should be based on different guidelines than those for adult ECG diagnostics. In the second case, the fetal ECG is used to visualize the origin of fetal supraventricular extrasystoles and the results suggest that the fetal ECG might in future serve as diagnostic tool for relating fetal arrhythmia to congenital heart diseases. In the last case, the non-invasive fetal ECG is compared to the invasively recorded fetal ECG to gauge the SNR of the transabdominal recordings and to demonstrate the suitability of the non-invasive fetal ECG in clinical applications that, as yet, are only possible for the invasive fetal ECG

    Advanced analyses of physiological signals and their role in Neonatal Intensive Care

    Get PDF
    Preterm infants admitted to the neonatal intensive care unit (NICU) face an array of life-threatening diseases requiring procedures such as resuscitation and invasive monitoring, and other risks related to exposure to the hospital environment, all of which may have lifelong implications. This thesis examined a range of applications for advanced signal analyses in the NICU, from identifying of physiological patterns associated with neonatal outcomes, to evaluating the impact of certain treatments on physiological variability. Firstly, the thesis examined the potential to identify infants at risk of developing intraventricular haemorrhage, often interrelated with factors leading to preterm birth, mechanical ventilation, hypoxia and prolonged apnoeas. This thesis then characterised the cardiovascular impact of caffeine therapy which is often administered to prevent and treat apnoea of prematurity, finding greater pulse pressure variability and enhanced responsiveness of the autonomic nervous system. Cerebral autoregulation maintains cerebral blood flow despite fluctuations in arterial blood pressure and is an important consideration for preterm infants who are especially vulnerable to brain injury. Using various time and frequency domain correlation techniques, the thesis found acute changes in cerebral autoregulation of preterm infants following caffeine therapy. Nutrition in early life may also affect neurodevelopment and morbidity in later life. This thesis developed models for identifying malnutrition risk using anthropometry and near-infrared interactance features. This thesis has presented a range of ways in which advanced analyses including time series analysis, feature selection and model development can be applied to neonatal intensive care. There is a clear role for such analyses in early detection of clinical outcomes, characterising the effects of relevant treatments or pathologies and identifying infants at risk of later morbidity

    Extraction of ECGs for twin pregnancies

    Get PDF
    The wellbeing of a fetus or fetuses can be monitored by the fetal heart rate (fHR). There are several proposed methods for fHR monitoring; these include fetal phonocardiography (fPCG), fetal cardiography (fCTG) and fetal magnetocardiogram (fMCG). Although, according to the research reviewed, none of these methods are ideal for monitoring or estimating fHR. The fPCG method is highly sensitive to noise and can only be used late in the pregnancy. With fCTG, the ultrasound transducer used for measuring the fHR needs to be properly aligned, otherwise the maternal heart rate (mHR) can be recorded instead of the fHR. In addition, the ultrasound high frequency exposure is not completely proven to be safe for the fetus. fMCG can detect fHR very accurately in comparison to the other methods but the method is unwieldy and expensive; thus not widely used in a clinical environment. Therefore, there is a need for technology which would be able to provide more information about the cardiac health of a fetus, delivered in a cost-effective, streamlined manner. Based on the research reviewed and captured within this dissertation, non-invasive fetal electrocardiography (fECG) has been identified as a promising fetal cardiac monitoring method and if researched further, has the potential to become the next mainstream approach for monitoring fetal health. Within this dissertation, the fECG extraction methods have been explored and the findings captured. The research revealed that the fECG method can be used from early stages of pregnancy (20 weeks gestational age onwards). It is relatively low cost and does not necessarily require a highly skilled user. Continuous monitoring is also possible. The main challenge identified when using the non-invasive fECG extraction method is poor Signal-to-Noise Ratio (SNR) of the fECG signal on the abdominal signal which consists of fECG, maternal ECG (mECG) and noise. Eleven different fECG extraction methods were tested as part of this dissertation. The extraction methods were based on Adaptive Methods (AM), Template Subtraction (TS)or Blind Source Separation (BSS). Synthetic test signals were used for the testing the methods. The test signals included five different noise levels across seven different single pregnancy physiological cases and one twin pregnancy case. Each recording included 34 channels (32 abdominal and two maternal reference channels). For single pregnancy cases all of the extraction methods were able to extract the fECG from the test signals with varying degrees of success. Overall, the BSS-JADE method was the top performing method for single pregnancy cases getting a median F1 score of 99.85%. Furthermore, the twin pregnancy case was tested using BSS methods. The BSS FastICA algorithm using symmetric approach was the top performing method for the twin pregnancy case receiving a median F1 score of 99.93%

    Algorithms and systems for home telemonitoring in biomedical applications

    Get PDF
    During the past decades, the interest of the healthcare community shifted from the simple treatment of the diseases towards the prevention and maintenance of a healthy lifestyle. This approach is associated to a reduced cost for the Health Systems, having to face the constantly increased expenditures due to the reduced mortality for chronical diseases and to the progressive population ageing. Nevertheless, the high costs related to hospitalization of patients for monitoring procedures that could be better performed at home hamper the full implementation of this approach in a traditional way. Information and Communication Technology can provide a solution to implement a care model closer to the patient, crossing the physical boundaries of the hospitals and thus allowing to reach also those patients that, for a geographical or social condition, could not access the health services as other luckier subjects. This is the case of telemonitoring systems, whose aim is that of providing monitoring services for some health-related parameters at a distance, by means of custom-designed electronic devices. In this thesis, the specific issues associated to two telemonitoring applications are presented, along with the proposed solutions and the achieved results. The first telemonitoring application considered is the fetal electrocardiography. Non-invasive fetal electrocardiography is the recording of the fetal heart electrical activity using electrodes placed on the maternal abdomen. It can provide important diagnostic parameters, such as the beat-to-beat heart rate variability, whose recurring analysis would be useful in assessing and monitoring fetal health during pregnancy. Long term electrocardiographic monitoring is sustained by the absence of any collateral effects for both the mother and the fetus. This application has been tackled from several perspectives, mainly acquisition and processing. From the acquisition viewpoint a study on different skin treatments, disposable commercial electrodes and textile electrodes has been performed with the aim of improving the signal acquisition quality, while simplifying the measurement setup. From the processing viewpoint, different algorithms have been developed to allow extracting the fetal ECG heart rate, starting from an on-line ICA algorithm or exploiting a subtractive approach to work on recordings acquired with a reduced number of electrodes. The latter, took part to the international "Physionet/Computing in Cardiology Challenge" in 2013 entering into the top ten best-performing open-source algorithms. The improved version of this algorithm is also presented, which would mark the 5th and 4th position in the final ranking related to the fetal heart rate and fetal RR interval measurements performance, reserved to the open-source challenge entries, taking into account both official and unofficial entrants. The research in this field has been carried out in collaboration with the Pediatric Cardiology Unit of the Hospital G. Brotzu in Cagliari, for the acquisition of non-invasive fetal ECG signals from pregnant voluntary patients. The second telemonitoring application considered is the telerehabilitation of the hand. The execution of rehabilitation exercises has been proven to be effective in recovering hand functionality in a wide variety of invalidating diseases, but the lack of standardization and continuous medical control cause the patients neglecting this therapeutic procedures. Telemonitoring the rehabilitation sessions would allow the physician to closely follow the patients' progresses and compliance to the prescribed adapted exercises. This application leads to the development of a sensorized telerehabilitation system for the execution and objective monitoring of therapeutic exercises at the patients' home and of the telemedicine infrastructure that give the physician the opportunity to monitor patients' progresses through parameters summarizing the patients' performance. The proposed non-CE marked medical device, patent pending, underwent a clinical trial, reviewed and approved by the Italian Public Health Department, involving 20 patients with Rheumatoid Arthritis and 20 with Systemic Sclerosis randomly assigned to the experimental or the control arm, enrolled for 12 weeks in a home rehabilitation program. The trial, carried out with the collaboration of the Rheumatology Department of the Policlinico Universitario of Cagliari, revealed promising results in terms of hand functionality recovering, highlighting greater improvements for the patients enrolled in the experimental arm, that use the proposed telerehabilitation system, with respect to those of the control arm, which perform similar rehabilitation exercises using common objects