14 research outputs found

    Active Charge Balancing for Cardiac Stimulation

    Get PDF
    Worldwide, there are about 3 million people who have pacemakers, with 10,000 new implantations of ICD’s each month. [heart.org] Due to the gravity and importance of the function that ICD’s provide, these devices must be extremely reliable and highly effective. However, because of the high tolerances of IC manufacturing, stimulation circuits for pacemakers may be slightly unmatched and over time, may have a net DC charge applied to the tissues in the heart. Extra charge pumped into body tissues is dangerous for the patient’s health; the pH of the tissue can be raised and corrosion of the stimulating electrodes may occur. This project entails the study and design of methods that allow balanced stimulation of cardiac tissue. Due to the expense of manufacturing integrated circuits, this project aims only to have representative simulations of our circuit solutions. By using dynamic current matching, we hope to cancel out the DC charge inadvertently applied to the heart in a cost effective manner

    Neuromodulation: present and emerging methods.

    Get PDF
    Neuromodulation has wide ranging potential applications in replacing impaired neural function (prosthetics), as a novel form of medical treatment (therapy), and as a tool for investigating neurons and neural function (research). Voltage and current controlled electrical neural stimulation (ENS) are methods that have already been widely applied in both neuroscience and clinical practice for neuroprosthetics. However, there are numerous alternative methods of stimulating or inhibiting neurons. This paper reviews the state-of-the-art in ENS as well as alternative neuromodulation techniques-presenting the operational concepts, technical implementation and limitations-in order to inform system design choices

    A Partial-Current-Steering Biphasic Stimulation Driver for Vestibular Prostheses

    No full text
    Published versio

    An Energy-Efficient, Dynamic Voltage Scaling Neural Stimulator for a Proprioceptive Prosthesis

    Get PDF
    Accepted versio

    A Multi-Channel Stimulator With High-Resolution Time-to-Current Conversion for Vagal-Cardiac Neuromodulation

    Get PDF
    This paper presents an integrated stimulator for a cardiac neuroprosthesis aiming to restore the parasympathetic control after heart transplantation. The stimulator is based on time-to-current conversion. Instead of the conventional current mode digital-to-analog converter (DAC) that uses ten of microamp for biasing, the proposed design uses a novel capacitor time-based DAC offering close to 10 bit of current amplitude resolution while using only a bias current 250 nA. The stimulator chip was design in a 0.18 m CMOS high-voltage (HV) technology. It consists of 16 independent channels, each capable of delivering 550 A stimulus current under a HV output stage that can be operated up to 30 V. Featuring both power efficiency and high-resolution current amplitude stimulation, the design is suitable for multi-channel neural simulation applications

    A charge-metering method for voltage-mode neural stimulation

    Get PDF
    AbstractElectrical neural stimulation is the technique used to modulate neural activity by inducing an instantaneous charge imbalance. This is typically achieved by injecting a constant current and controlling the stimulation time. However, constant voltage stimulation is found to be more energy-efficient although it is challenging to control the amount of charge delivered. This paper presents a novel, fully integrated circuit for facilitating charge-metering in constant voltage stimulation. It utilises two complementary stimulation paths. Each path includes a small capacitor, a comparator and a counter. They form a mixed-signal integrator that integrates the stimulation current onto the capacitor while monitoring its voltage against a threshold using the comparator. The pulses from the comparator are used to increment the counter and reset the capacitor. Therefore, by knowing the value of the capacitor, threshold voltage and output of the counter, the quantity of charge delivered can be calculated. The system has been fabricated in 0.18μm CMOS technology, occupying a total active area of 339μm×110μm. Experimental results were taken using: (1) a resistor–capacitor EEI model and (2) platinum electrodes with ringer solution. The viability of this method in recruiting action potentials has been demonstrated using a cuff electrode with Xenopus sciatic nerve. For a 10nC target charge delivery, the results of (2) show a charge delivery error of 3.4% and a typical residual charge of 77.19pC without passive charge recycling. The total power consumption is 45μW. The performance is comparable with other publications. Therefore, the proposed stimulation method can be used as a new approach for neural stimulation

    Low power circuits and systems for wireless neural stimulation

    Get PDF
    Thesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Electrical Engineering and Computer Science, 2011.Cataloged from PDF version of thesis.Includes bibliographical references (p. 155-161).Electrical stimulation of tissues is an increasingly valuable tool for treating a variety of disorders, with applications including cardiac pacemakers, cochlear implants, visual prostheses, deep brain stimulators, spinal cord stimulators, and muscle stimulators. Brain implants for paralysis treatments are increasingly providing sensory feedback via neural stimulation. Within the field of neuroscience, the perturbation of neuronal circuits wirelessly in untethered, freely-behaving animals is of particular importance. In implantable systems, power consumption is often the limiting factor in determining battery or power coil size, cost, and level of tissue heating, with stimulation circuitry typically dominating the power budget of the entire implant. Thus, there is strong motivation to improve the energy efficiency of implantable electrical stimulators. In this thesis, I present two examples of low-power tissue stimulators. The first type is a wireless, low-power neural stimulation system for use in freely behaving animals. The system consists of an external transmitter and a miniature, implantable wireless receiver-and-stimulator utilizing a custom integrated chip built in a standard 0.5 ptm CMOS process. Low power design permits 12 days of continuous experimentation from a 5 mAh battery, extended by an automatic sleep mode that reduces standby power consumption by 2.5x. To test this device, bipolar stimulating electrodes were implanted into the songbird motor nucleus HVC of zebra finches. Single-neuron recordings revealed that wireless stimulation of HVC led to a strong increase of spiking activity in its downstream target, the robust nucleus of the arcopallium (RA). When this device was used to deliver biphasic pulses of current randomly during singing, singing activity was prematurely terminated in all birds tested. The second stimulator I present is a novel, energy-efficient electrode stimulator with feedback current regulation. This stimulator uses inductive storage and recycling of energy based on a dynamic power supply to drive an electrode in an adiabatic fashion such that energy consumption is minimized. Since there are no explicit current sources or current limiters, wasteful energy dissipation across such elements is naturally avoided. The stimulator also utilizes a shunt current-sensor to monitor and regulate the current through the electrode via feedback, thus enabling flexible and safe stimulation. The dynamic power supply allows efficient transfer of energy both to and from the electrode, and is based on a DC-DC converter topology that is used in a bidirectional fashion. In an exemplary electrode implementation, I show how the stimulator combines the efficiency of voltage control and the safety and accuracy of current control in a single low-power integrated-circuit built in a standard 0.35 pm CMOS process. I also perform a theoretical analysis of the energy efficiency that is in accord with experimental measurements. In its current proof-of-concept implementation, this stimulator achieves a 2x-3x reduction in energy consumption as compared to a conventional current-source-based stimulator operating from a fixed power supply.by Scott Kenneth Arfin.Ph.D
    corecore