4,434 research outputs found
Fog Computing in Medical Internet-of-Things: Architecture, Implementation, and Applications
In the era when the market segment of Internet of Things (IoT) tops the chart
in various business reports, it is apparently envisioned that the field of
medicine expects to gain a large benefit from the explosion of wearables and
internet-connected sensors that surround us to acquire and communicate
unprecedented data on symptoms, medication, food intake, and daily-life
activities impacting one's health and wellness. However, IoT-driven healthcare
would have to overcome many barriers, such as: 1) There is an increasing demand
for data storage on cloud servers where the analysis of the medical big data
becomes increasingly complex, 2) The data, when communicated, are vulnerable to
security and privacy issues, 3) The communication of the continuously collected
data is not only costly but also energy hungry, 4) Operating and maintaining
the sensors directly from the cloud servers are non-trial tasks. This book
chapter defined Fog Computing in the context of medical IoT. Conceptually, Fog
Computing is a service-oriented intermediate layer in IoT, providing the
interfaces between the sensors and cloud servers for facilitating connectivity,
data transfer, and queryable local database. The centerpiece of Fog computing
is a low-power, intelligent, wireless, embedded computing node that carries out
signal conditioning and data analytics on raw data collected from wearables or
other medical sensors and offers efficient means to serve telehealth
interventions. We implemented and tested an fog computing system using the
Intel Edison and Raspberry Pi that allows acquisition, computing, storage and
communication of the various medical data such as pathological speech data of
individuals with speech disorders, Phonocardiogram (PCG) signal for heart rate
estimation, and Electrocardiogram (ECG)-based Q, R, S detection.Comment: 29 pages, 30 figures, 5 tables. Keywords: Big Data, Body Area
Network, Body Sensor Network, Edge Computing, Fog Computing, Medical
Cyberphysical Systems, Medical Internet-of-Things, Telecare, Tele-treatment,
Wearable Devices, Chapter in Handbook of Large-Scale Distributed Computing in
Smart Healthcare (2017), Springe
Contactless Electrocardiogram Monitoring with Millimeter Wave Radar
The electrocardiogram (ECG) has always been an important biomedical test to
diagnose cardiovascular diseases. Current approaches for ECG monitoring are
based on body attached electrodes leading to uncomfortable user experience.
Therefore, contactless ECG monitoring has drawn tremendous attention, which
however remains unsolved. In fact, cardiac electrical-mechanical activities are
coupling in a well-coordinated pattern. In this paper, we achieve contactless
ECG monitoring by breaking the boundary between the cardiac mechanical and
electrical activity. Specifically, we develop a millimeter-wave radar system to
contactlessly measure cardiac mechanical activity and reconstruct ECG without
any contact in. To measure the cardiac mechanical activity comprehensively, we
propose a series of signal processing algorithms to extract 4D cardiac motions
from radio frequency (RF) signals. Furthermore, we design a deep neural network
to solve the cardiac related domain transformation problem and achieve
end-to-end reconstruction mapping from RF input to the ECG output. The
experimental results show that our contactless ECG measurements achieve timing
accuracy of cardiac electrical events with median error below 14ms and
morphology accuracy with median Pearson-Correlation of 90% and median
Root-Mean-Square-Error of 0.081mv compared to the groudtruth ECG. These results
indicate that the system enables the potential of contactless, continuous and
accurate ECG monitoring
Evaluation of spatial-temporal anomalies in the analysis of human movement
The dissemination of Internet of Things solutions, such as smartphones, lead to the
appearance of devices that allow to monitor the activities of their users. In manufacture,
the performed tasks consist on sets of predetermined movements that are exhaustively
repeated, forming a repetitive behaviour. Additionally, there are planned and unplanned events on manufacturing production lines which cause the repetitive behaviour to stop. The execution of improper movements and the existence of events that might prejudice the productive system are regarded as anomalies.
In this work, it was investigated the feasibility of the evaluation of spatial-temporal
anomaly detection in the analysis of human movement. It is proposed a framework capable of detecting anomalies in generic repetitive time series, thus being adequate to handle Human motion from industrial scenarios. The proposed framework consists of (1) a new unsupervised segmentation algorithm; (2) feature extraction, selection and dimensionality reduction; (3) unsupervised classification based on DBSCAN used to distinguish normal and anomalous instances.
The proposed solution was applied in four different datasets. Two of those datasets
were synthetic and two were composed of real-world data, namely, electrocardiography
data and human movement in manufacture. The yielded results demonstrated not only
that anomaly detection in human motion is possible, but that the developed framework
is generic and, with examples, it was shown that it may be applied in general repetitive
time series with little adaptation effort for different domains.
The results showed that the proposed framework has the potential to be applied in
manufacturing production lines to monitor the employees movements, acting as a tool to detect both planned and unplanned events, and ultimately reduce the risk of appearance of musculoskeletal disorders in industrial settings in long-term
Blind Source Separation for the Processing of Contact-Less Biosignals
(Spatio-temporale) Blind Source Separation (BSS) eignet sich für die Verarbeitung von Multikanal-Messungen im Bereich der kontaktlosen Biosignalerfassung. Ziel der BSS ist dabei die Trennung von (z.B. kardialen) Nutzsignalen und Störsignalen typisch für die kontaktlosen Messtechniken. Das Potential der BSS kann praktisch nur ausgeschöpft werden, wenn (1) ein geeignetes BSS-Modell verwendet wird, welches der Komplexität der Multikanal-Messung gerecht wird und (2) die unbestimmte Permutation unter den BSS-Ausgangssignalen gelöst wird, d.h. das Nutzsignal praktisch automatisiert identifiziert werden kann. Die vorliegende Arbeit entwirft ein Framework, mit dessen Hilfe die Effizienz von BSS-Algorithmen im Kontext des kamera-basierten Photoplethysmogramms bewertet werden kann. Empfehlungen zur Auswahl bestimmter Algorithmen im Zusammenhang mit spezifischen Signal-Charakteristiken werden abgeleitet. Außerdem werden im Rahmen der Arbeit Konzepte für die automatisierte Kanalauswahl nach BSS im Bereich der kontaktlosen Messung des Elektrokardiogramms entwickelt und bewertet. Neuartige Algorithmen basierend auf Sparse Coding erwiesen sich dabei als besonders effizient im Vergleich zu Standard-Methoden.(Spatio-temporal) Blind Source Separation (BSS) provides a large potential to process distorted multichannel biosignal measurements in the context of novel contact-less recording techniques for separating distortions from the cardiac signal of interest. This potential can only be practically utilized (1) if a BSS model is applied that matches the complexity of the measurement, i.e. the signal mixture and (2) if permutation indeterminacy is solved among the BSS output components, i.e the component of interest can be practically selected. The present work, first, designs a framework to assess the efficacy of BSS algorithms in the context of the camera-based photoplethysmogram (cbPPG) and characterizes multiple BSS algorithms, accordingly. Algorithm selection recommendations for certain mixture characteristics are derived. Second, the present work develops and evaluates concepts to solve permutation indeterminacy for BSS outputs of contact-less electrocardiogram (ECG) recordings. The novel approach based on sparse coding is shown to outperform the existing concepts of higher order moments and frequency-domain features
Sensors for Vital Signs Monitoring
Sensor technology for monitoring vital signs is an important topic for various service applications, such as entertainment and personalization platforms and Internet of Things (IoT) systems, as well as traditional medical purposes, such as disease indication judgments and predictions. Vital signs for monitoring include respiration and heart rates, body temperature, blood pressure, oxygen saturation, electrocardiogram, blood glucose concentration, brain waves, etc. Gait and walking length can also be regarded as vital signs because they can indirectly indicate human activity and status. Sensing technologies include contact sensors such as electrocardiogram (ECG), electroencephalogram (EEG), photoplethysmogram (PPG), non-contact sensors such as ballistocardiography (BCG), and invasive/non-invasive sensors for diagnoses of variations in blood characteristics or body fluids. Radar, vision, and infrared sensors can also be useful technologies for detecting vital signs from the movement of humans or organs. Signal processing, extraction, and analysis techniques are important in industrial applications along with hardware implementation techniques. Battery management and wireless power transmission technologies, the design and optimization of low-power circuits, and systems for continuous monitoring and data collection/transmission should also be considered with sensor technologies. In addition, machine-learning-based diagnostic technology can be used for extracting meaningful information from continuous monitoring data
Vectorcardiography-derived index allows a robust quantification of ventricular electrical synchrony
Alteration of muscle activation sequence is a key mechanism in heart failure with reduced ejection fraction. Successful cardiac resynchronization therapy (CRT), which has become standard therapy in these patients, is limited by the lack of precise dyssynchrony quantification. We implemented a computational pipeline that allows assessment of ventricular dyssynchrony by vectorcardiogram reconstruction from the patient’s electrocardiogram. We defined a ventricular dyssynchrony index as the distance between the voltage and speed time integrals of an individual observation and the linear fit of these variables obtained from a healthy population. The pipeline was tested in a 1914-patient population. The dyssynchrony index showed minimum values in heathy controls and maximum values in patients with left bundle branch block (LBBB) or with a pacemaker (PM). We established a critical dyssynchrony index value that discriminates electrical dyssynchronous patterns (LBBB and PM) from ventricular synchrony. In 10 patients with PM or CRT devices, dyssynchrony indexes above the critical value were associated with high time to peak strain standard deviation, an echocardiographic measure of mechanical dyssynchrony. Our index proves to be a promising tool to evaluate ventricular activation dyssynchrony, potentially enhancing the selection of candidates for CRT, device configuration during implantation, and post-implant optimization.Fil: Fernández, Juan Manuel Francisco. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata. Instituto de Física de Líquidos y Sistemas Biológicos. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Instituto de Física de Líquidos y Sistemas Biológicos; ArgentinaFil: Spagnuolo, Damián N.. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata. Instituto de Física de Líquidos y Sistemas Biológicos. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Instituto de Física de Líquidos y Sistemas Biológicos; ArgentinaFil: Politi, María T.. Universidad de Buenos Aires; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Houssay. Instituto de Fisiología y Biofísica Bernardo Houssay. Universidad de Buenos Aires. Facultad de Medicina. Instituto de Fisiología y Biofísica Bernardo Houssay; ArgentinaFil: Tello Santacruz, Iván A.. Hospital Británico de Buenos Aires; ArgentinaFil: Schiavone, Miguel. Hospital Británico de Buenos Aires; ArgentinaFil: Cáceres Monié, César. Hospital Británico de Buenos Aires; ArgentinaFil: Avaca, Horacio A.. Hospital Británico de Buenos Aires; ArgentinaFil: Chara, Osvaldo. Universidad Argentina de la Empresa; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata. Instituto de Física de Líquidos y Sistemas Biológicos. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Instituto de Física de Líquidos y Sistemas Biológicos; Argentina. Technische Universität Dresden; Alemani
Non-Invasive Identification of Atrial Fibrillation Driver Location Using the 12-lead ECG: Pulmonary Vein Rotors vs. other Locations
Atrial fibrillation (AF) is an irregular heart rhythm due to disorganized atrial electrical activity, often sustained by rotational drivers called rotors. In the present work, we sought to characterize and discriminate whether simulated single stable rotors are located in the pulmonary veins (PVs) or not, only by using non-invasive signals (i.e., the 12-lead ECG). Several features have been extracted from the signals, such as Hjort descriptors, recurrence quantification analysis (RQA), and principal component analysis. All the extracted features have shown significant discriminatory power, with particular emphasis to the RQA parameters. A decision tree classifier achieved 98.48% accuracy, 83.33% sensitivity, and 100% specificity on simulated data.Clinical Relevance-This study might guide ablation procedures, suggesting doctors to proceed directly in some patients with a pulmonary veins isolation, and avoiding the prior use of an invasive atrial mapping system
- …