834 research outputs found

    Fear of exercise and health-related quality of life in patients with an implantable cardioverter defibrillator

    Get PDF
    Several studies have reported improved survival rates thanks to the use of an implantable cardioverter defibrillator (ICD) in the treatment of patients with life-threatening arrhythmia. However, the effects of the ICD on health-related quality of life (HR-QoL) of these patients are not clear. The aim of this study is to describe HR-QoL and fear of exercise in ICD patients. Eighty-nine ICD patients from the University Hospital in Groningen, the Netherlands, participated in this study. HR-QoL was measured using the Rand-36 and the Quality of Life After Myocardial Infarction Dutch language version questionnaires. Fear of exercise was measured using the Tampa Scale for Kinesiophobia, Dutch version and the Fear Avoidance Beliefs Questionnaire, Dutch version. Association between outcome variables was analysed by linear regression analyses. Study results show that the HR-QoL of patients with ICDs in our study population is significantly worse than that of normal healthy people. Furthermore, fear of exercise is negatively associated with HR-QoL corrected for sex, age and number of years living with an ICD. After implantation of the ICD, patients with a clear fear of exercise should be identified and interventions should be considered in order to increase their HR-QoL

    Assessing the deterrent effect of symbolic guardianship through neighbourhood watch signs and police signs: a virtual reality study

    Get PDF
    This study examines the deterrent effects of neighbourhood watch signs and police signs as measures of symbolic guardianship on burglars versus non-offenders. In a virtual reality experiment, 181 burglars and 172 non-offenders scouted a virtual neighbourhood and were exposed to neighbourhood watch signs and/or signs suggesting police surveillance in the area. With neighbourhood watch signs present, both burglars and non-offenders perceived the neighbourhood residents as more likely to intervene. Burglars were also more likely to select a target closer to the exit than non-offenders when neighbourhood watch signs were present. The presence of police signs reduced the time spent scouting and the distance travelled for both burglars and non-offenders. Furthermore, as compared to non-offenders burglars selected houses with easier access, travelled less distance, and reported higher anticipation of neighbourhood resident intervention. Symbolic guardianship through neighbourhood watch or police sign seems to elicit only small effects in deterring burglars. They should not immediately be discounted as preventive measures, however, as small-effect interventions may be valuable as additions to well-established interventions

    Automated mobile virtual reality cognitive behavior therapy for aviophobia in a natural setting: a randomized controlled trial

    Get PDF
    Background: Access to evidence-based psychological treatment is a challenge worldwide. We assessed the effectiveness of a fully automated aviophobia smartphone app treatment delivered in combination with a $5 virtual reality (VR) viewer.Methods: In total, 153 participants from the Dutch general population with aviophobia symptoms and smartphone access were randomized in a single-blind randomized controlled trial to either an automated VR cognitive behavior therapy (VR-CBT) app treatment condition (n = 77) or a wait-list control condition (n = 76). The VR-CBT app was delivered over a 6-week period in the participants' natural environment. Online self-report assessments were completed at baseline, post-treatment, at 3-month and at 12-month follow-up. The primary outcome measure was the Flight Anxiety Situations Questionnaire (FAS). Analyses were based on intent-to-treat.Results: A significant reduction of aviophobia symptoms at post-test for the VR-CBT app compared with the control condition [p Conclusions: This study is the first to show that fully automated mobile VR-CBT therapy delivered in a natural setting can maintain long-term effectiveness in reducing aviophobia symptoms. In doing so, it offers an accessible and scalable evidence-based treatment solution that can be applied globally at a fraction of the cost of current treatment alternatives

    Heart rate increase and inappropriate sinus tachycardia after cryoballoon pulmonary vein isolation for atrial fibrillation

    Get PDF
    Background: Cryoballoon pulmonary vein isolation (PVI) is a common therapy for atrial fibrillation (AF). While moderately increased sinus rhythm heart rate (HR) after PVI has been observed, inappropriate sinus tachycardia (IST) is a rare phenomenon. We aimed to investigate the prevalence and natural history of an abnormal sinus HR response after cryoballoon PVI. Methods: We included 169/646 (26.2%) patients with AF undergoing PVI with available Holter recordings before and 3, 6 and 12 months after the procedure. Patients with AF on Holter monitoring were excluded. Mean HR increase >= 20 bpm or an IST-like pattern (mean HR > 90 bpm or > 80 bpm when beta-blocking agents were used) following PVI was categorised as abnormal sinus HR response. Results: Following PVI, mean HR +/- standard deviation increased in the entire group from 63.5 +/- 8.4 to 69.1 +/- 9.9 bpm at 3 months (p < 0.001), and to 71.9 +/- 9.4 bpm at 6 months (p < 0.001). At 12 months, mean HR was 71.2 +/- 10.1 bpm (p < 0.001). Only 7/169 patients (4.1%) met criteria for abnormal sinus HR response: mean HR was 61.9 +/- 10.6 bpm (pre-ablation), 84.6 +/- 9.8 bpm (3 months), 80.1 +/- 6.5 bpm (6 months) and 76.3 +/- 10.1 bpm (12 months). Even at 12 months, mean HR was significantly different from that pre-ablation in this group (p = 0.033). However, in patients meeting IST-like pattern criteria, mean HR at 12 months was no longer significantly different from that pre-ablation. Conclusion: Few patients had an abnormal sinus HR response after PVI. Peak HR was observed 3 months after PVI, but HR was still significantly increased 12 months post-ablation compared with pre-ablation. An IST-like pattern was rarely observed. In these patients, HR decreased to pre-ablation values within a year

    Gut-microbe derived TMAO and its association with more progressed forms of AF:Results from the AF-RISK study

    Get PDF
    Introduction: The importance of gut microbiome in cardiovascular disease has been increasingly recognized. Trimethylamine N-oxide (TMAO) is a gut microbe-derived metabolite that is associated with cardiovascular disease, including atrial fibrillation (AF). The role of TMAO in clinical AF progression however remains unknown. Methods and results: In this study we measured TMAO and its precursor (betaine, choline, and L- carnitine) levels in 78 patients using plasma samples from patients that participated in the AF-RISK study. 56 patients suffered from paroxysmal AF and 22 had a short history of persistent AF. TMAO levels were significantly higher in patients with persistent AF, as compared to those with paroxysmal AF (median [IQR] 5.65 [4.7–9.6] m/z versus 4.31 [3.2–6.2] m/z, p < 0.05), while precursor levels did not differ. In univariate analysis, we observed that for every unit increase in TMAO, the odds for having persistent AF increased with 0.44 [0.14–0.73], p < 0.01. Conclusion: These results suggest that higher levels of TMAO are associated with more progressed forms of AF. We therefore hypothesize that increased TMAO levels may reflect disease progression in humans. Larger studies are required to validate these preliminary findings.Trial Registration number: Clinicaltrials.gov NCT01510210

    Stroke risk in patients with device-detected atrial high-rate episodes

    Get PDF
    Cardiovascular implantable electronic devices (CIEDs) can detect atrial arrhythmias, i.e. atrial high-rate episodes (AHRE). The thrombo-embolic risk in patients showing AHRE appears to be lower than in patients with clinical atrial fibrillation (AF) and it is unclear whether the former will benefit from oral anticoagulants. Based on currently available evidence, it seems reasonable to consider antithrombotic therapy in patients without documented AF showing AHRE >24 hours and a CHA(2)DS(2)-VASc score (congestive heart failure, hypertension, age >= 75 years [doubled], diabetes mellitus, prior stroke [doubled], vascular disease, age 65-74 years and female sex) >= 1, awaiting definite answers from ongoing randomised clinical trials. In patients with AHR

    Instrumental Music Influences Recognition of Emotional Body Language

    Get PDF
    In everyday life, emotional events are perceived by multiple sensory systems. Research has shown that recognition of emotions in one modality is biased towards the emotion expressed in a simultaneously presented but task irrelevant modality. In the present study, we combine visual and auditory stimuli that convey similar affective meaning but have a low probability of co-occurrence in everyday life. Dynamic face-blurred whole body expressions of a person grasping an object while expressing happiness or sadness are presented in combination with fragments of happy or sad instrumental classical music. Participants were instructed to categorize the emotion expressed by the visual stimulus. The results show that recognition of body language is influenced by the auditory stimuli. These findings indicate that crossmodal influences as previously observed for audiovisual speech can also be obtained from the ignored auditory to the attended visual modality in audiovisual stimuli that consist of whole bodies and music

    c-Axis tunneling in YBa2Cu3O7-\delta/PrBa2Cu3O7-\delta superlattices

    Full text link
    In this work we report c-axis conductance measurements done on a superlattice based on a stack of 2 layers YBa2Cu3O{7-\delta} and 7 layers PrBa2Cu3O{7-\delta} (2:7). We find that these quasi-2D structures show no clear superconducting coupling along the c-axis. Instead, we observe tunneling with a gap of \Delta_c=5.0\pm 0.5 meV for the direction perpendicular to the superconducting planes. The conductance spectrum show well defined quasi-periodic structures which are attributed to the superlattice structure. From this data we deduce a low temperature c-axis coherence length of \xi_c=0.24\pm 0.03 nm.Comment: 15 pages, 5 figures. To appear in Phys.Rev.

    First-line treatment of persistent and long-standing persistent atrial fibrillation with single-stage hybrid ablation:a 2-year follow-up study

    Get PDF
    AIMS: This study evaluates the efficacy and safety of first-line single-stage hybrid ablation of (long-standing) persistent atrial fibrillation (AF), over a follow-up period of 2 years, and provides additional information on arrhythmia recurrences and electrophysiological findings at repeat ablation. METHODS AND RESULTS: This is a prospective cohort study that included 49 patients (65% persistent AF; 35% long-standing persistent AF) who underwent hybrid ablation as first-line ablation treatment (no previous endocardial ablation). Patients were relatively young (57.0 ± 8.5 years) and predominantly male (89.8%). Median CHA2DS2-VASc score was 1.0 (0.5; 2.0) and mean left atrium volume index was 43.7 ± 10.9 mL/m2. Efficacy was assessed by 12-lead electrocardiography and 72-h Holter monitoring after 3, 6, 12, and 24 months. Recurrence was defined as AF/atrial flutter (AFL)/tachycardia (AT) recorded by electrocardiography or Holter monitoring lasting >30 s during 2-year follow-up. At 2-year follow-up, single and multiple procedure success rates were 67% and 82%, respectively. Two (4%) patients experienced a major complication (bleeding) requiring intervention following hybrid ablation. Among the 16 (33%) patients who experienced an AF/AFL/AT recurrence, 13 (81%) were ATs/AFLs and only 3 (19%) were AF. Repeat ablation was performed in 10 (20%) patients and resulted in sinus rhythm in 7 (70%) at 2-year follow-up. CONCLUSION: First-line single-stage hybrid AF ablation is an effective treatment strategy for patients with persistent and long-standing persistent AF with an acceptable rate of major complications. Recurrences are predominantly AFL/AT that can be successfully ablated percutaneously. Hybrid ablation seems a feasible approach for first-line ablation of (long-standing) persistent AF

    Pharmacokinetic role of protein binding of mycophenolic acid and its glucuronide metabolite in renal transplant recipients

    Get PDF
    Mycophenolic acid (MPA), the active compound of mycophenolate mofetil (MMF), is used to prevent graft rejection in renal transplant recipients. MPA is glucuronidated to the metabolite MPAG, which exhibits enterohepatic recirculation (EHC). MPA binds for 97% and MPAG binds for 82% to plasma proteins. Low plasma albumin concentrations, impaired renal function and coadministration of cyclosporine have been reported to be associated with increased clearance of MPA. The aim of the study was to develop a population pharmacokinetic model describing the relationship between MMF dose and total MPA (tMPA), unbound MPA (fMPA), total MPAG (tMPAG) and unbound MPAG (fMPAG). In this model the correlation between pharmacokinetic parameters and renal function, plasma albumin concentrations and cotreatment with cyclosporine was quantified. tMPA, fMPA, tMPAG and fMPAG concentration–time profiles of renal transplant recipients cotreated with cyclosporine (n = 48) and tacrolimus (n = 45) were analyzed using NONMEM. A 2- and 1-compartment model were used to describe the pharmacokinetics of fMPA and fMPAG. The central compartments of fMPA and fMPAG were connected with an albumin compartment allowing competitive binding (bMPA and bMPAG). tMPA and tMPAG were modeled as the sum of the bound and unbound concentrations. EHC was modeled by transport of fMPAG to a separate gallbladder compartment. This transport was decreased in case of cyclosporine cotreatment (P < 0.001). In the model, clearance of fMPAG decreased when creatinine clearance (CrCL) was reduced (P < 0.001), and albumin concentration was correlated with the maximum number of binding sites available for MPA and MPAG (P < 0.001). In patients with impaired renal function cotreated with cyclosporine the model adequately described that increasing fMPAG concentrations decreased tMPA AUC due to displacement of MPA from its binding sites. The accumulated MPAG could also be reconverted to MPA by the EHC, which caused increased tMPA AUC in patients cotreated with tacrolimus. Changes in CrCL had hardly any effect on fMPA exposure. A decrease in plasma albumin concentration from 0.6 to 0.4 mmol/l resulted in ca. 38% reduction of tMPA AUC, whereas no reduction in fMPA AUC was seen. In conclusion, a pharmacokinetic model has been developed which describes the relationship between dose and both total and free MPA exposure. The model adequately describes the influence of renal function, plasma albumin and cyclosporine co-medication on MPA exposure. Changes in protein binding due to altered renal function or plasma albumin concentrations influence tMPA exposure, whereas fMPA exposure is hardly affected
    corecore