240 research outputs found

    DOES MAGNETIC RESONANCE IMAGING PROVIDE SUPERIOR RELIABILITY FOR ACHILLES AND PATELLAR TENDON CROSS-SECTIONAL AREA MEASUREMENTS COMPARED WITH ULTRASOUND IMAGING?

    Get PDF
    This study investigated the reliability of Achilles and patellar tendon cross-sectional area (CSA) measurement using ultrasound imaging (USI) and magnetic resonance imaging (MRI). Fifteen healthy adults were imaged twice on two occasions, interrupted by a tendon loading protocol. Tendon CSA segmentations were conducted by an experienced and an inexperienced rater blinded to information regarding subject, session and loading status. USI provided good test-retest reliability (intra-class correlation coefficient [ICC] 2,1 > 0.85, standard error of measurement [SEM] 5%-6%), while with MRI it was excellent (ICC 2,1 > 0.92, SEM 4%) for the experienced rater. This study suggests that MRI provides superior reliability for tendon CSA measurements compared with USI. However, the difference in reliability between the methods was small, and the results were inconclusive regarding objectivity and sensitivity to change when assessed based on the effect of loading. We concluded that both methods can be used for reliable CSA measurements of the Achilles and patellar tendons when using a highly standardized measurement protocol and when conducted by an experienced rater. (C) 2019 World Federation for Ultrasound in Medicine & Biology. All rights reserved.Peer reviewe

    Infrared microspectroscopic determination of collagen cross-links in articular cartilage

    Get PDF
    Collagen forms an organized network in articular cartilage to give tensile stiffness to the tissue. Due to its long half-life, collagen is susceptible to cross-links caused by advanced glycation end-products. The current standard method for determination of cross-link concentrations in tissues is the destructive high-performance liquid chromatography (HPLC). The aim of this study was to analyze the cross-link concentrations nondestructively from standard unstained histological articular cartilage sections by using Fourier transform infrared (FTIR) microspectroscopy. Half of the bovine articular cartilage samples (n = 27) were treated with threose to increase the collagen cross-linking while the other half (n = 27) served as a control group. Partial least squares (PLS) regression with variable selection algorithms was used to predict the cross-link concentrations from the measured average FTIR spectra of the samples, and HPLC was used as the reference method for cross-link concentrations. The correlation coefficients between the PLS regression models and the biochemical reference values were r = 0.84 (p <0.001), r = 0.87 (p <0.001) and r = 0.92 (p <0.001) for hydroxylysyl pyridinoline (HP), lysyl pyridinoline (LP), and pentosidine (Pent) cross-links, respectively. The study demonstrated that FTIR microspectroscopy is a feasible method for investigating cross-link concentrations in articular cartilage. (C) The Authors. Published by SPIE under a Creative Commons Attribution 3.0 Unported License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI.Peer reviewe

    Success Rate and Technical Quality of Home Polysomnography With Self-Applicable Electrode Set in Subjects With Possible Sleep Bruxism

    Get PDF
    Using sleep laboratory polysomnography (PSG) is restricted for the diagnosis of only the most severe sleep disorders due to its low availability and high cost. Home PSG is more affordable, but applying conventional electroencephalography (EEG) electrodes increases its overall complexity and lowers the availability. Simple, self-administered single-channel EEG monitors on the other hand suffer from poor reliability. In this study, we aimed to quantify the reliability of self-administrated home PSG recordings conducted with a newly designed ambulatory electrode set (AES) that enables multichannel EEG, electrooculography, electromyography, and electrocardiography recordings. We assessed the sleep study success rate and technical quality of the recordings performed in subjects with possible sleep bruxism (SB). Thirty-two females and five males aged 39.6 +/- 11.6 years (mean +/- SD) with self-reported SB were recruited in the study. Self-administrated home PSG recordings with two AES designs were conducted (n = 19 and 21). The technical quality of the recordings was graded based on the proportion of interpretable data. Technical failure rate for AES (both designs) was 5% and SB was scorable for 96.9% of all recorded data. Only one recording failed due to mistakes in self-applying the AES. We found that the proportion of good quality self-administrated EEG recordings is significantly higher when multiple channels are used compared to using a single channel. Sleep study success rates and proportion of recordings with high quality interpretable data from EEG channels of AES were comparable to that of conventional home PSG. Self-applicable AES has potential to become a reliable tool for widely available home PSG.Peer reviewe

    Towards a Deeper Understanding of Sleep Stages through their Representation in the Latent Space of Variational Autoencoders

    Get PDF
    Artificial neural networks show great success in sleep stage classification, with an accuracy comparable to human scoring. While their ability to learn from labelled electroencephalography (EEG) signals is widely researched, the underlying learning processes remain unexplored. Variational autoencoders can capture the underlying meaning of data by encoding it into a low-dimensional space. Regularizing this space furthermore enables the generation of realistic representations of data from latent space samples. We aimed to show that this model is able to generate realistic sleep EEG. In addition, the generated sequences from different areas of the latent space are shown to have inherent meaning. The current results show the potential of variational autoencoders in understanding sleep EEG data from the perspective of unsupervised machine learning

    Near-Infrared Spectroscopy Enables Arthroscopic Histologic Grading of Human Knee Articular Cartilage

    Get PDF
    Purpose: To develop the means to estimate cartilage histologic grades and proteoglycan content in ex vivo arthroscopy using near-infrared spectroscopy (NIRS). Methods: In this experimental study, arthroscopic NIR spectral measurements were performed on both knees of 9 human cadavers, followed by osteochondral block extraction and in vitro measurements: reacquisition of spectra and reference measurements (proteoglycan content, and three histologic scores). A hybrid model, combining principal component analysis and linear mixed-effects model (PCA-LME), was trained for each reference to investigate its relationship with in vitro NIR spectra. The performance of the PCA-LME model was validated with ex vivo spectra before and after the exclusion of outlying spectra. Model performance was evaluated based on Spearman rank correlation (ρ) and root-mean-square error (RMSE). Results: The PCA-LME models performed well (independent test: average ρ = 0.668, RMSE = 0.892, P < .001) in the prediction of the reference measurements based on in vitro data. The performance on ex vivo arthroscopic data was poorer but improved substantially after outlier exclusion (independent test: average ρ = 0.462 to 0.614, RMSE = 1.078 to 0.950, P = .019 to .008). Conclusions: NIRS is capable of nondestructive evaluation of cartilage integrity (i.e., histologic scores and proteoglycan content) under similar conditions as in clinical arthroscopy. Clinical Relevance: There are clear clinical benefits to the accurate assessment of cartilage lesions in arthroscopy. Visual grading is the current standard of care. However, optical techniques, such as NIRS, may provide a more objective assessment of cartilage damage.publishedVersionPeer reviewe

    Beat-to-beat cardiac repolarization lability increases during hypoxemia and arousals in obstructive sleep apnea patients

    Get PDF
    Obstructive sleep apnea (OSA) is associated with the progression of cardiovascular diseases, arrhythmias, and sudden cardiac death (SCD). However, the acute impacts of OSA and its consequences on heart function are not yet fully elucidated. We hypothesized that desaturation events acutely destabilize ventricular repolarization, and the presence of accompanying arousals magnifies this destabilization. Ventricular repolarization lability measures, comprising heart rate corrected QT (QTc), short-time-variability of QT (STVQT), and QT variability index (QTVI), were calculated before, during, and after 20,955 desaturations from lead II electrocardiography signals of 492 patients with suspected OSA (52% men). Variations in repolarization parameters were assessed during and after desaturations, both with and without accompanying arousals, and groupwise comparisons were performed based on desaturation duration and depth. Regression analyses were used to investigate the influence of confounding factors, comorbidities, and medications. The standard deviation (SD) of QT, mean QTc, SDQTc, and STVQT increased significantly (P < 0.01), whereas QTVI decreased (P < 0.01) during and after desaturations. The changes in SDQT, mean QTc, SDQTc, and QTVI were significantly amplified (P < 0.01) in the presence of accompanying arousals. Desaturation depth was an independent predictor of increased SDQTc (ÎČ = 0.405, P < 0.01), STVQT (ÎČ = 0.151, P < 0.01), and QTVI (ÎČ = 0.009, P < 0.01) during desaturation. Desaturations cause acute changes in ventricular repolarization, with deeper desaturations and accompanying arousals independently contributing to increased ventricular repolarization lability. This may partially explain the increased risk of arrhythmias and SCD in patients with OSA, especially when the OSA phenotype includes high hypoxic load and fragmented sleep

    Inter-sleep stage variations in corrected QT interval differ between obstructive sleep apnea patients with and without stroke history

    Get PDF
    Obstructive sleep apnea (OSA) is related to the progression of cardiovascular diseases (CVD); it is an independent risk factor for stroke and is also prevalent post-stroke. Furthermore, heart rate corrected QT (QTc) is an important predictor of the risk of arrhythmia and CVD. Thus, we aimed to investigate QTc interval variations in different sleep stages in OSA patients and whether nocturnal QTc intervals differ between OSA patients with and without stroke history. 18 OSA patients (apnea-hypopnea index (AHI)≄15) with previously diagnosed stroke and 18 OSA patients (AHI≄15) without stroke history were studied. Subjects underwent full polysomnography including an electrocardiogram measured by modified lead II configuration. RR, QT, and QTc intervals were calculated in all sleep stages. Regression analysis was utilized to investigate possible confounding effects of sleep stages and stroke history on QTc intervals. Compared to patients without previous stroke history, QTc intervals were significantly higher (ÎČ = 34, p<0.01) in patients with stroke history independent of age, sex, body mass index, and OSA severity. N3 sleep (ÎČ = 5.8, p<0.01) and REM sleep (ÎČ = 2.8, p<0.01) increased QTc intervals in both patient groups. In addition, QTc intervals increased progressively (p<0.05) towards deeper sleep in both groups; however, the magnitude of changes compared to the wake stage was significantly higher (p<0.05) in patients with stroke history. The findings of this study indicate that especially in deeper sleep, OSA patients with a previous stroke have an elevated risk for QTc prolongation further increasing the risk for ventricular arrhythmogenicity and sudden cardiac death.publishedVersionPeer reviewe

    Self-applied somnography : technical feasibility of electroencephalography and electro-oculography signal characteristics in sleep staging of suspected sleep-disordered adults

    Get PDF
    Funding Information: Financial support for this study was provided by the European Union's Horizon 2020 Research and Innovation Programme under grant agreement No 965417, by the Research Committee of the Kuopio University Hospital Catchment Area for the State Research Funding (Grants 5041807, 5041804, 5041803, 5041797, and 5041794), by the Finnish Cultural Foundation through Kainuu Regional Fund and Central fund, by Olvi Foundation, by the Finnish Anti‐Tuberculosis Association, by Tampere Tuberculosis Foundation, by the Research Foundation of the Pulmonary Diseases, by the NordForsk (NordSleep Project 90458) through the Business Finland (Grant 5133/31/2018), by the Kuopio University Hospital Research Foundation, and The Icelandic Centre for Research. Publisher Copyright: © 2023 The Authors. Journal of Sleep Research published by John Wiley & Sons Ltd on behalf of European Sleep Research Society.Sleep recordings are increasingly being conducted in patients’ homes where patients apply the sensors themselves according to instructions. However, certain sensor types such as cup electrodes used in conventional polysomnography are unfeasible for self-application. To overcome this, self-applied forehead montages with electroencephalography and electro-oculography sensors have been developed. We evaluated the technical feasibility of a self-applied electrode set from Nox Medical (Reykjavik, Iceland) through home sleep recordings of healthy and suspected sleep-disordered adults (n = 174) in the context of sleep staging. Subjects slept with a double setup of conventional type II polysomnography sensors and self-applied forehead sensors. We found that the self-applied electroencephalography and electro-oculography electrodes had acceptable impedance levels but were more prone to losing proper skin–electrode contact than the conventional cup electrodes. Moreover, the forehead electroencephalography signals recorded using the self-applied electrodes expressed lower amplitudes (difference 25.3%–43.9%, p < 0.001) and less absolute power (at 1–40 Hz, p < 0.001) than the polysomnography electroencephalography signals in all sleep stages. However, the signals recorded with the self-applied electroencephalography electrodes expressed more relative power (p < 0.001) at very low frequencies (0.3–1.0 Hz) in all sleep stages. The electro-oculography signals recorded with the self-applied electrodes expressed comparable characteristics with standard electro-oculography. In conclusion, the results support the technical feasibility of the self-applied electroencephalography and electro-oculography for sleep staging in home sleep recordings, after adjustment for amplitude differences, especially for scoring Stage N3 sleep.Peer reviewe

    Near infrared spectroscopic evaluation of biochemical and crimp properties of knee joint ligaments and patellar tendon

    Get PDF
    Knee ligaments and tendons play an important role in stabilizing and controlling the motions of the knee. Injuries to the ligaments can lead to abnormal mechanical loading of the other supporting tissues (e.g., cartilage and meniscus) and even osteoarthritis. While the condition of knee ligaments can be examined during arthroscopic repair procedures, the arthroscopic evaluation suffers from subjectivity and poor repeatability. Near infrared spectroscopy (NIRS) is capable of non-destructively quantifying the composition and structure of collagen-rich connective tissues, such as articular cartilage and meniscus. Despite the similarities, NIRS-based evaluation of ligament composition has not been previously attempted. In this study, ligaments and patellar tendon of ten bovine stifle joints were measured with NIRS, followed by chemical and histological reference analysis. The relationship between the reference properties of the tissue and NIR spectra was investigated using partial least squares regression. NIRS was found to be sensitive towards the water (R2CV = .65) and collagen (R2CV = .57) contents, while elastin, proteoglycans, and the internal crimp structure remained undetectable. As collagen largely determines the mechanical response of ligaments, we conclude that NIRS demonstrates potential for quantitative evaluation of knee ligaments.publishedVersionPeer reviewe

    Increased nocturnal arterial pulsation frequencies of obstructive sleep apnoea patients is associated with an increased number of lapses in a psychomotor vigilance task.

    Get PDF
    To access publisher's full text version of this article, please click on the hyperlink in Additional Links field or click on the hyperlink at the top of the page marked DownloadObjectives: Besides hypoxaemia severity, heart rate variability has been linked to cognitive decline in obstructive sleep apnoea (OSA) patients. Thus, our aim was to examine whether the frequency domain features of a nocturnal photoplethysmogram (PPG) can be linked to poor performance in the psychomotor vigilance task (PVT). Methods: PPG signals from 567 suspected OSA patients, extracted from Type 1 diagnostic polysomnography, and corresponding results of PVT were retrospectively examined. The frequency content of complete PPGs was determined, and analyses were conducted separately for men (n=327) and women (n=240). Patients were grouped into PVT performance quartiles based on the number of lapses (reaction times ≄500 ms) and within-test variation in reaction times. The best-performing (Q1) and worst-performing (Q4) quartiles were compared due the lack of clinical thresholds in PVT. Results: We found that the increase in arterial pulsation frequency (APF) in both men and women was associated with a higher number of lapses. Higher APF was also associated with higher within-test variation in men, but not in women. Median APF (ÎČ=0.27, p=0.01), time spent under 90% saturation (ÎČ=0.05, p<0.01), female sex (ÎČ=1.29, p<0.01), older age (ÎČ=0.03, p<0.01) and subjective sleepiness (ÎČ=0.07, p<0.01) were significant predictors of belonging to Q4 based on lapses. Only female sex (ÎČ=0.75, p<0.01) and depression (ÎČ=0.91, p<0.02) were significant predictors of belonging to Q4 based on the within-test variation. Conclusions: In conclusion, increased APF in PPG provides a possible polysomnography indicator for deteriorated vigilance especially in male OSA patients. This finding highlights the connection between cardiorespiratory regulation, vigilance and OSA. However, our results indicate substantial sex-dependent differences that warrant further prospective studies.Research Committee of the Kuopio University Hospital Catchment Area for the State Research Funding Academy of Finland Seinajoki Central Hospital Competitive State Research Financing of Expert Responsibility Area of Tampere University Hospital VTR3242 Business Finland Paulo Foundation Paivikki & Sakari Sohlberg Foundation Research Foundation of the Pulmonary Diseases Finnish Cultural Foundation Alfred Kordelin Foundation Tampere Tuberculosis Foundation Respiratory Foundation of Kuopio Regio
    • 

    corecore