9,263 research outputs found
Protein sensing and discrimination using highly functionalised ruthenium( ii ) tris(bipyridyl) protein surface mimetics in an array format
Ruthenium(II) tris(bipyridyl) protein surface mimetics are used in an array format to sense and discriminate proteins including therapeutically relevant targets, hDM2 and MCL-1, using linear discriminant analysis (LDA)
Simplicial gauge theory on spacetime
We define a discrete gauge-invariant Yang-Mills-Higgs action on spacetime
simplicial meshes. The formulation is a generalization of classical lattice
gauge theory, and we prove consistency of the action in the sense of
approximation theory. In addition, we perform numerical tests of convergence
towards exact continuum results for several choices of gauge fields in pure
gauge theory.Comment: 18 pages, 2 figure
Similarity solutions for unsteady shear-stress-driven flow of Newtonian and power-law fluids : slender rivulets and dry patches
Unsteady flow of a thin film of a Newtonian fluid or a non-Newtonian power-law fluid with power-law index N driven by a constant shear stress applied at the free surface, on a plane inclined at an angle α to the horizontal, is considered. Unsteady similarity solutions representing flow of slender rivulets and flow around slender dry patches are obtained. Specifically, solutions are obtained for converging sessile rivulets (0 < α < π/2) and converging dry patches in a pendent film (π/2 < α < π), as well as for diverging pendent rivulets and diverging dry patches in a sessile film. These solutions predict that at any time t, the rivulet and dry patch widen or narrow according to |x|3/2, and the film thickens or thins according to |x|, where x denotes distance down the plane, and that at any station x, the rivulet and dry patch widen or narrow like |t|−1, and the film thickens or thins like |t|−1, independent of N
Recommended from our members
CAD in mammography: lesion-level versus case-level analysis of the effects of prompts on human decisions
Object: To understand decision processes in CAD-supported breast screening by analysing how prompts affect readers’ judgements of individual mammographic features (lesions). To this end we analysed hitherto unexamined details of reports completed by mammogram readers in an earlier evaluation of a CAD tool.
Material and methods: Assessments of lesions were extracted from 5,839 reports for 59 cancer cases. Statistical analyses of these data focused on what features readers considered when recalling a cancer case and how readers reacted to CAD prompts.
Results: About 13.5% of recall decisions were found to be caused by responses to features other than those indicating actual cancer. Effects of CAD: lesions were more likely to be examined if prompted; the presence of a prompt on a cancer increased the probability of both detection and recall especially for less accurate readers in subtler cases; lack of prompts made cancer features less likely to be detected; false prompts made non-cancer features more likely to be classified as cancer.
Conclusion: The apparent lack of impact reported for CAD in some studies is plausibly due to CAD systematically affecting readers’ identification of individual features, in a beneficial way for certain combinations of readers and features and a damaging way for others. Mammogram readers do not ignore prompts. Methodologically, assessing CAD by numbers of recalled cancer cases may be misleading
A ‘quiet revolution’? The impact of Training Schools on initial teacher training partnerships
This paper discusses the impact on initial teacher training of a new policy initiative in England: the introduction of Training Schools. First, the Training School project is set in context by exploring the evolution of a partnership approach to initial teacher training in England. Ways in which Training Schools represent a break with established practice are considered together with their implications for the dominant mode of partnership led by higher education institutions (HEIs). The capacity of Training Schools to achieve their own policy objectives is examined, especially their efficacy as a strategy for managing innovation and the dissemination of innovation. The paper
ends by focusing on a particular Training School project which has adopted an unusual approach to its work and enquires whether this alternative approach could offer a more profitable way forward. During the course of the paper, five different models of partnership are considered:
collaborative, complementary, HEI-led, school-led and partnership within a partnership
Inspiratory muscle warm-up does not improve cycling time-trial performance
Purpose: This study examined the effects of an active cycling warm-up, with and without the addition of an inspiratory muscle warm-up (IMW), on 10-km cycling time-trial performance
The analysis of acetaminophen (paracetamol) and seven metabolites in rat, pig and human plasma by U(H)PLC–MS
A U(H)PLC–MS/MS method is described for the analysis of acetaminophen and its sulphate, glucuronide, glutathione, cysteinyl and N-acetylcysteinyl metabolites in plasma using stable isotope-labeled internal standards. P-Aminophenol glucuronide and 3-methoxyacetaminophen were monitored and semi-quantified using external standards. The assay takes 7.5 min/sample, requires only 5 μl of plasma and involves minimal sample preparation. The method was validated for rat plasma and cross validated for human and pig plasma and mouse serum. LOQ in plasma for these analytes were 0.44 μg/ml (APAP-C), 0.58 μg/ml (APAP-SG), 0.84 μg/ml (APAP-NAC), 2.75 μg/ml (APAP-S), 3.00 μg/ml (APAP-G) and 16 μg/ml (APAP). Application of the method is illustrated by the analysis of plasma following oral administration of APAP to male Han Wistar rats
A Decision Analysis Evaluating Screening for Kidney Cancer Using Focused Renal Ultrasound
Background
Screening for renal cell carcinoma (RCC) has been identified as a key research priority; however, no randomised control trials have been performed. Value of information analysis can determine whether further research on this topic is of value.
Objective
To determine (1) whether current evidence suggests that screening is potentially cost effective and, if so, (2) in which age/sex groups, (3) identify evidence gaps, and (4) estimate the value of further research to close those gaps.
Design, setting, and participants
A decision model was developed evaluating screening in asymptomatic individuals in the UK. A National Health Service perspective was adopted.
Intervention
A single focused renal ultrasound scan compared with standard of care (no screening).
Outcome measurements and statistical analysis
Expected lifetime costs, quality-adjusted life years (QALYs), and incremental cost-effectiveness ratio (ICER), discounted at 3.5% per annum.
Results and limitations
Given a prevalence of RCC of 0.34% (0.18–0.54%), screening 60-yr-old men resulted in an ICER of £18 092/QALY (€22 843/QALY). Given a prevalence of RCC of 0.16% (0.08–0.25%), screening 60-yr-old women resulted in an ICER of £37 327/QALY (€47 129/QALY). In the one-way sensitivity analysis, the ICER was <£30 000/QALY as long as the prevalence of RCC was ≥0.25% for men and ≥0.2% for women at age 60 yr. Given the willingness to pay a threshold of £30 000/QALY (€37 878/QALY), the population-expected values of perfect information were £194 million (€244 million) and £97 million (€123 million) for 60-yr-old men and women, respectively. The expected value of perfect parameter information suggests that the prevalence of RCC and stage shift associated with screening are key research priorities.
Conclusions
Current evidence suggests that one-off screening of 60-yr-old men is potentially cost effective and that further research into this topic would be of value to society.
Patient summary
Economic modelling suggests that screening 60-yr-old men for kidney cancer using ultrasound may be a good use of resources and that further research on this topic should be performed
Electron transport through 8-oxoG: NEGF/DFT study
We present a first-principles study of the conductance of Guanine and 8-Oxoguanine (8-oxoG) attached to Au(111) electrodes. Cellular levels of 8-oxoG have been found in larger concentrations in cancer patients. The current through the structure was calculated using a DFT–NEGF formalism. We have compared flat and pyramidal electrode geometries and show that there is a measurable difference between the I–V characteristics of the pristine molecule and the 8-oxoG. For a flat electrode geometry, 8-oxoG produces a 2.57 (18.3) times increase in current than the corresponding counterpart at 3 V with a bond separation of 1.2 Å (2.4 Å). This can be attributed to molecular orbital energies shifting at the junction. Overall the flat geometry produces larger currents. We have also investigated the sensitivity of the current to the electrode molecule separation. For the flat geometry, the current dropped approximately 80% (97%) for 8-oxoG (pristine Guanine) with the doubling of the electrode separation
- …