305 research outputs found

    Cold Atom Clock Test of Lorentz Invariance in the Matter Sector

    Full text link
    We report on a new experiment that tests for a violation of Lorentz invariance (LI), by searching for a dependence of atomic transition frequencies on the orientation of the spin of the involved states (Hughes-Drever type experiment). The atomic frequencies are measured using a laser cooled 133^{133}Cs atomic fountain clock, operating on a particular combination of Zeeman substates. We analyze the results within the framework of the Lorentz violating standard model extension (SME), where our experiment is sensitive to a largely unexplored region of the SME parameter space, corresponding to first measurements of four proton parameters and improvements by 11 and 13 orders of magnitude on the determination of four others. In spite of the attained uncertainties, and of having extended the search into a new region of the SME, we still find no indication of LI violation.Comment: 4 pages, accepted for Physical Review Letter

    Testing Local Lorentz and Position Invariance and Variation of Fundamental Constants by searching the Derivative of the Comparison Frequency Between a Cryogenic Sapphire Oscillator and Hydrogen Maser

    Full text link
    The cryogenic sapphire oscillator (CSO) at the Paris Observatory has been continuously compared to various Hydrogen Masers since 2001. The early data sets were used to test Local Lorentz Invariance in the Robertson-Mansouri-Sexl (RMS) framework by searching for sidereal modulations with respect to the Cosmic Microwave Background, and represent the best Kennedy-Thorndike experiment to date. In this work we present continuous operation over a period of greater than six years from September 2002 to December 2008 and present a more precise way to analyze the data by searching the time derivative of the comparison frequency. Due to the long-term operation we are able to search both sidereal and annual modulations. The results gives P_{KT} = \beta_{RMS}-\alpha_{RMS}-1 = -1.7(4.0) \times 10^{-8} for the sidereal and -23(10) \times 10^{-8} for the annual term, with a weighted mean of -4.8(3.7) \times 10^{-8}, a factor of 8 better than previous. Also, we analyze the data with respect to a change in gravitational potential for both diurnal and annual variations. The result gives \beta_{H-Maser} - \beta_{CSO} = -2.7(1.4) \times 10^{-4} for the annual and -6.9(4.0) \times 10^{-4} for the diurnal terms, with a weighted mean of -3.2(1.3) \times 10^{-4}. This result is two orders of magnitude better than other tests that use electromagnetic resonators. With respect to fundamental constants a limit can be provided on the variation with ambient gravitational potential and boost of a combination of the fine structure constant (\alpha), the normalized quark mass (m_q), and the electron to proton mass ratio (m_e/m_p), setting the first limit on boost dependence of order 10^{-10}.Comment: Fixed typo

    Tests of relativity using a microwave resonator

    Get PDF
    The frequencies of a cryogenic sapphire oscillator and a hydrogen maser are compared to set new constraints on a possible violation of Lorentz invariance. We determine the variation of the oscillator frequency as a function of its orientation (Michelson-Morley test) and of its velocity (Kennedy-Thorndike test) with respect to a preferred frame candidate. We constrain the corresponding parameters of the Mansouri and Sexl test theory to δβ+1/2=(1.5±4.2)×109\delta - \beta + 1/2 = (1.5\pm 4.2) \times 10^{-9} and βα1=(3.1±6.9)×107\beta - \alpha - 1 = (-3.1\pm 6.9) \times 10^{-7} which is equivalent to the best previous result for the former and represents a 30 fold improvement for the latter.Comment: 8 pages, 2 figures, submitted to Physical Review Letters (October 3, 2002

    Palliative Portal Vein Stent Placement in Malignant and Symptomatic Extrinsic Portal Vein Stenosis or Occlusion

    Get PDF
    This article evaluates the results of portal vein (PV) stent placement in patients with malignant extrinsic lesions stenosing or obstructing the PV and causing symptomatic PV hypertension (PVHT). Fourteen patients with bile duct cancer (n=7), pancreatic adenocarcinoma (n=4), or another cancer (n=3) underwent percutaneous transhepatic portal venous stent placement because of gastroesophageal or jejunal varices (n=9), ascites (n=7), and/or thrombocytopenia (n=2). Concurrent tumoral obstruction of the main bile duct was treated via the transhepatic route in the same session in four patients. Changes in portal venous pressure, complications, stent patency, and survival were evaluated. Mean±standard deviation (SD) gradient of portal venous pressure decreased significantly immediately after stent placement from 11.2mmHg±4.6 to 1.1mmHg±1.0 (P<0.00001). Three patients had minor complications, and one developed a liver abscess. During a mean±SD follow-up of 134.4±123.3days, portal stents remained patent in 11 patients (78.6%); stent occlusion occurred in 3 patients, 2 of whom had undergone previous major hepatectomy. After stent placement, PVHT symptoms were relieved in four (57.1%) of seven patients who died (mean survival, 97±71.2days), and relieved in six (85.7%) of seven patients still alive at the end of follow-up (mean follow-up, 171.7±153.5days). Stent placement in the PV is feasible and relatively safe. It helped to relieve PVHT symptoms in a single sessio

    Evaluation of Doppler Shifts to Improve the Accuracy of Primary Atomic Fountain Clocks

    Full text link
    We demonstrate agreement between measurements and ab initio calculations of the frequency shifts caused by distributed cavity phase variations in the microwave cavity of a primary atomic fountain clock. Experimental verification of the finite element models of the cavities gives the first quantitative evaluation of this leading uncertainty and allows it to be reduced to delta nu / nu = 8.4\times10^-17. Applying these experimental techniques to clocks with improved microwave cavities will yield negligible distributed cavity phase uncertainties, less than \pm1\times10^-17.Comment: To appear in PR

    Ultra-stable clock laser system development towards space applications

    Get PDF
    International audienceThe increasing performance of optical lattice clocks has made them attractive for scientific applications in space and thus has pushed the development of their components including the interrogation lasers of the clock transitions towards being suitable for space, which amongst others requires making them more power efficient, radiation hardened, smaller, lighter as well as more mechanically stable. Here we present the development towards a space-compatible interrogation laser system for a strontium lattice clock constructed within the Space Optical Clock (SOC2) project where we have concentrated on mechanical rigidity and size. The laser reaches a fractional frequency instability of 7.9 × 10−16 at 300 ms averaging time. The laser system uses a single extended cavity diode laser that gives enough power for interrogating the atoms, frequency comparison by a frequency comb and diagnostics. It includes fibre link stabilisation to the atomic package and to the comb. The optics module containing the laser has dimensions 60 × 45 × 8 cm3; and the ultra-stable reference cavity used for frequency stabilisation with its vacuum system takes 30 × 30 × 30 cm3. The acceleration sensitivities in three orthogonal directions of the cavity are 3.6 × 10−10/g, 5.8 × 10−10/g and 3.1 × 10−10/g, where g ≈ 9.8 m/s2 is the standard gravitational acceleration

    Long-distance frequency dissemination with a resolution of 10-17

    Get PDF
    We use a new technique to disseminate microwave reference signals along ordinary optical fiber. The fractional frequency resolution of a link of 86 km in length is 10-17 for a one day integration time, a resolution higher than the stability of the best microwave or optical clocks. We use the link to compare the microwave reference and a CO2/OsO4 frequency standard that stabilizes a femtosecond laser frequency comb. This demonstrates a resolution of 3.10-14 at 1 s. An upper value of the instability introduced by the femtosecond laser-based synthesizer is estimated as 1.10-14 at 1 s

    Cold atoms in space: community workshop summary and proposed road-map

    Get PDF
    We summarise the discussions at a virtual Community Workshop on Cold Atoms in Space concerning the status of cold atom technologies, the prospective scientific and societal opportunities offered by their deployment in space, and the developments needed before cold atoms could be operated in space. The cold atom technologies discussed include atomic clocks, quantum gravimeters and accelerometers, and atom interferometers. Prospective applications include metrology, geodesy and measurement of terrestrial mass change due to, e.g., climate change, and fundamental science experiments such as tests of the equivalence principle, searches for dark matter, measurements of gravitational waves and tests of quantum mechanics. We review the current status of cold atom technologies and outline the requirements for their space qualification, including the development paths and the corresponding technical milestones, and identifying possible pathfinder missions to pave the way for missions to exploit the full potential of cold atoms in space. Finally, we present a first draft of a possible road-map for achieving these goals, that we propose for discussion by the interested cold atom, Earth Observation, fundamental physics and other prospective scientific user communities, together with the European Space Agency (ESA) and national space and research funding agencies

    Cold atoms in space: community workshop summary and proposed road-map

    Get PDF
    We summarise the discussions at a virtual Community Workshop on Cold Atoms in Space concerning the status of cold atom technologies, the prospective scientific and societal opportunities offered by their deployment in space, and the developments needed before cold atoms could be operated in space. The cold atom technologies discussed include atomic clocks, quantum gravimeters and accelerometers, and atom interferometers. Prospective applications include metrology, geodesy and measurement of terrestrial mass change due to, e.g., climate change, and fundamental science experiments such as tests of the equivalence principle, searches for dark matter, measurements of gravitational waves and tests of quantum mechanics. We review the current status of cold atom technologies and outline the requirements for their space qualification, including the development paths and the corresponding technical milestones, and identifying possible pathfinder missions to pave the way for missions to exploit the full potential of cold atoms in space. Finally, we present a first draft of a possible road-map for achieving these goals, that we propose for discussion by the interested cold atom, Earth Observation, fundamental physics and other prospective scientific user communities, together with the European Space Agency (ESA) and national space and research funding agencies.publishedVersio
    corecore