18 research outputs found

    Limit of detection for second-order calibration methods

    Get PDF
    Analytical chemistry can be split into two main types, qualitative and quantitative. Most modern analytical chemistry is quantitative. Popular sensitivity to health issues is aroused by the mountains of government regulations that use science to, for instance, provide public health information to prevent disease caused by harmful exposure to toxic substances. The concept of the minimum amount of an analyte or compound that can be detected or analysed appears in many of these regulations (for example, to discard the presence of traces of toxic substances in foodstuffs) generally as a part of method validation aimed at reliably evaluating the validity of the measurements.The lowest quantity of a substance that can be distinguished from the absence of that substance (a blank value) is called the detection limit or limit of detection (LOD). Traditionally, in the context of simple measurements where the instrumental signal only depends on the amount of analyte, a multiple of the blank value is taken to calculate the LOD (traditionally, the blank value plus three times the standard deviation of the measurement). However, the increasing complexity of the data that analytical instruments can provide for incoming samples leads to situations in which the LOD cannot be calculated as reliably as before.Measurements, instruments and mathematical models can be classified according to the type of data they use. Tensorial theory provides a unified language that is useful for describing the chemical measurements, analytical instruments and calibration methods. Instruments that generate two-dimensional arrays of data are second-order instruments. A typical example is a spectrofluorometer, which provides a set of emission spectra obtained at different excitation wavelengths.The calibration methods used with each type of data have different features and complexity. In this thesis, the most commonly used calibration methods are reviewed, from zero-order (or univariate) to second-order (or multi-linears) calibration models. Second-order calibration models are treated in details since they have been applied in the thesis.Concretely, the following methods are described:- PARAFAC (Parallel Factor Analysis)- ITTFA (Iterative Target Transformation Analysis)- MCR-ALS (Multivariate Curve Resolution-Alternating Least Squares)- N-PLS (Multi-linear Partial Least Squares)Analytical methods should be validated. The validation process typically starts by defining the scope of the analytical procedure, which includes the matrix, target analyte(s), analytical technique and intended purpose. The next step is to identify the performance characteristics that must be validated, which may depend on the purpose of the procedure, and the experiments for determining them. Finally, validation results should be documented, reviewed and maintained (if not, the procedure should be revalidated) as long as the procedure is applied in routine work.The figures of merit of a chemical analytical process are 'those quantifiable terms which may indicate the extent of quality of the process. They include those terms that are closely related to the method and to the analyte (sensitivity, selectivity, limit of detection, limit of quantification, ...) and those which are concerned with the final results (traceability, uncertainty and representativity) (Inczédy et al., 1998). The aim of this thesis is to develop theoretical and practical strategies for calculating the limit of detection for complex analytical situations. Specifically, I focus on second-order calibration methods, i.e. when a matrix of data is available for each sample.The methods most often used for making detection decisions are based on statistical hypothesis testing and involve a choice between two hypotheses about the sample. The first hypothesis is the "null hypothesis": the sample is analyte-free. The second hypothesis is the "alternative hypothesis": the sample is not analyte-free. In the hypothesis test there are two possible types of decision errors. An error of the first type occurs when the signal for an analyte-free sample exceeds the critical value, leading one to conclude incorrectly that the sample contains a positive amount of the analyte. This type of error is sometimes called a "false positive". An error of the second type occurs if one concludes that a sample does not contain the analyte when it actually does and it is known as a "false negative". In zero-order calibration, this hypothesis test is applied to the confidence intervals of the calibration model to estimate the LOD as proposed by Hubaux and Vos (A. Hubaux, G. Vos, Anal. Chem. 42: 849-855, 1970).One strategy for estimating multivariate limits of detection is to transform the multivariate model into a univariate one. This strategy has been applied in this thesis in three practical applications:1. LOD for PARAFAC (Parallel Factor Analysis).2. LOD for ITTFA (Iterative Target Transformation Factor Analysis).3. LOD for MCR-ALS (Multivariate Curve Resolution - Alternating Least Squares)In addition, the thesis includes a theoretical contribution with the proposal of a sample-dependent LOD in the context of multivariate (PLS) and multi-linear (N-PLS) Partial Least Squares.La Química Analítica es pot dividir en dos tipus d'anàlisis, l'anàlisi quantitativa i l'anàlisi qualitativa. La gran part de la química analítica moderna és quantitativa i fins i tot els govern fan ús d'aquesta ciència per establir regulacions que controlen, per exemple, nivells d'exposició a substàncies tòxiques que poden afectar la salut pública. El concepte de mínima quantitat d'un analit o component que es pot detectar apareix en moltes d'aquestes regulacions, en general com una part de la validació dels mètodes per tal de garantir la qualitat i la validesa dels resultats.La mínima quantitat d'una substància que pot ser diferenciada de l'absència d'aquesta substància (el que es coneix com un blanc) s'anomena límit de detecció (limit of detection, LOD). En procediments on es treballa amb mesures analítiques que són degudes només a la quantitat d'analit present a la mostra (situació d'ordre zero) el LOD es pot calcular com un múltiple de la mesura del blanc (tradicionalment, 3 vegades la desviació d'aquesta mesura). Tanmateix, l'evolució dels instruments analítics i la complexitat creixent de les dades que generen, porta a situacions en les que el LOD no es pot calcular fiablement d'una forma tan senzilla. Les mesures, els instruments i els models de calibratge es poden classificar en funció del tipus de dades que utilitzen. La Teoria Tensorial s'ha utilitzat en aquesta tesi per fer aquesta classificació amb un llenguatge útil i unificat. Els instruments que generen dades en dues dimensions s'anomenen instruments de segon ordre i un exemple típic és l'espectrofluorímetre d'excitació-emissió, que proporciona un conjunt d'espectres d'emissió obtinguts a diferents longituds d'ona d'excitació.Els mètodes de calibratge emprats amb cada tipus de dades tenen diferents característiques i complexitat. En aquesta tesi, es fa una revisió dels models de calibratge més habituals d'ordre zero (univariants), de primer ordre (multivariants) i de segon ordre (multilinears). Els mètodes de segon ordre estan tractats amb més detall donat que són els que s'han emprat en les aplicacions pràctiques portades a terme. Concretament es descriuen:- PARAFAC (Parallel Factor Analysis)- ITTFA (Iterative Target Transformation Analysis)- MCR-ALS (Multivariate Curve Resolution-Alternating Least Squares)- N-PLS (Multi-linear Partial Least Squares)Com s'ha avançat al principi, els mètodes analítics s'han de validar. El procés de validació inclou la definició dels límits d'aplicació del procediment analític (des del tipus de mostres o matrius fins l'analit o components d'interès, la tècnica analítica i l'objectiu del procediment). La següent etapa consisteix en identificar i estimar els paràmetres de qualitat (figures of merit, FOM) que s'han de validar per, finalment, documentar els resultats de la validació i mantenir-los mentre sigui aplicable el procediment descrit.Algunes FOM dels processos químics de mesura són: sensibilitat, selectivitat, límit de detecció, exactitud, precisió, etc. L'objectiu principal d'aquesta tesi és desenvolupar estratègies teòriques i pràctiques per calcular el límit de detecció per problemes analítics complexos. Concretament, està centrat en els mètodes de calibratge que treballen amb dades de segon ordre.Els mètodes més emprats per definir criteris de detecció estan basats en proves d'hipòtesis i impliquen una elecció entre dues hipòtesis sobre la mostra. La primera hipòtesi és la hipòtesi nul·la: a la mostra no hi ha analit. La segona hipòtesis és la hipòtesis alternativa: a la mostra hi ha analit. En aquest context, hi ha dos tipus d'errors en la decisió. L'error de primer tipus té lloc quan es determina que la mostra conté analit quan no en té i la probabilitat de cometre l'error de primer tipus s'anomena fals positiu. L'error de segon tipus té lloc quan es determina que la mostra no conté analit quan en realitat si en conté i la probabilitat d'aquest error s'anomena fals negatiu. En calibratges d'ordre zero, aquesta prova d'hipòtesi s'aplica als intervals de confiança de la recta de calibratge per calcular el LOD mitjançant les fórmules d'Hubaux i Vos (A. Hubaux, G. Vos, Anal. Chem. 42: 849-855, 1970)Una estratègia per a calcular límits de detecció quan es treballa amb dades de segon ordre es transformar el model multivariant en un model univariant. Aquesta estratègia s'ha fet servir en la tesi en tres aplicacions diferents::1. LOD per PARAFAC (Parallel Factor Analysis).2. LOD per ITTFA (Iterative Target Transformation Factor Analysis).3. LOD per MCR-ALS (Multivariate Curve Resolution - Alternating Least Squares)A més, la tesi inclou una contribució teòrica amb la proposta d'un LOD que és específic per cada mostra, en el context del mètode multivariant PLS i del multilinear N-PLS

    Synthesis of water-soluble hemicoronenediimides by photocyclization of perylenediimides: Turn-on fluorescent probes in water by complexation with Cucurbit[7]uril or binding to G-quadruplex Motifs

    Get PDF
    A new series of perylene and hemicoronene diimides, obtained by visible light photocyclization, are presented, between them some remarkable examples that are soluble in only water, and give nanoparticles by selfassociation. Those compounds work as new fluorescent materials in water by complexation with cucurbit[7] uril, as well as selective G-quadruplex binding ligands with remarkable cytotoxic activity when the interaction with G4 was sufficiently strong.We acknowledge the Ministerio de Ciencia, Innovación y Universidades-FEDER (Grants PID2019-111215RB-100 and RTI2018- 102040-B-100), the Junta de Castilla y León, Consejería de Educación y Cultura y Fondo Social Europeo (Grants BU263P18 and BU305P18), “la Caixa” Foundation (LCF/PR/PR12/11070003) for financial support. A. R.C. thanks Secretaría General de Universidades for a FPU18/03225 Grant. This research has made use of the high-performance computing resources of the Castilla y León Supercomputing Center (SCAYLE, htt ps://www.scayle.es), financed by FEDER (Fondo Europeo de Desarrollo Regional). We thank Ms. Ma del Pilar Castroviejo-Fernández, from PCT, UBU, for assistance in AFM studies and Mr. Javier Gutierrez-Reguera from LTI, UVA, for assistance in DLS studies

    Potentiation of amyloid beta phagocytosis and amelioration of synaptic dysfunction upon FAAH deletion in a mouse model of Alzheimer’s disease.

    Get PDF
    Background: The complex pathophysiology of Alzheimer’s disease (AD) hampers the development of effective treatments. Attempts to prevent neurodegeneration in AD have failed so far, highlighting the need for further clarification of the underlying cellular and molecular mechanisms. Neuroinflammation seems to play a crucial role in disease progression, although its specific contribution to AD pathogenesis remains elusive. We have previously shown that the modulation of the endocannabinoid system (ECS) renders beneficial effects in a context of amyloidosis, which triggers neuroinflammation. In the 5xFAD model, the genetic inactivation of the enzyme that degrades anandamide (AEA), the fatty acid amide hydrolase (FAAH), was associated with a significant amelioration of the memory deficit. Methods: In this work, we use electrophysiology, flow cytometry and molecular analysis to evaluate the cellular and molecular mechanisms underlying the improvement associated to the increased endocannabinoid tone in the 5xFAD mouse− model. Results: We demonstrate that the chronic enhancement of the endocannabinoid tone rescues hippocampal synaptic plasticity in the 5xFAD mouse model. At the CA3–CA1 synapse, both basal synaptic transmission and longterm potentiation (LTP) of synaptic transmission are normalized upon FAAH genetic inactivation, in a CB1 receptor (CB1R)- and TRPV1 receptor-independent manner. Dendritic spine density in CA1 pyramidal neurons, which is notably decreased in 6-month-old 5xFAD animals, is also restored. Importantly, we reveal that the expression of microglial factors linked to phagocytic activity, such as TREM2 and CTSD, and other factors related to amyloid beta clearance and involved in neuron–glia crosstalk, such as complement component C3 and complement receptor C3AR, are specifically upregulated in 5xFAD/FAAH−/− animals. Conclusion: In summary, our findings support the therapeutic potential of modulating, rather than suppressing, neuroinflammation in Alzheimer’s disease. In our model, the long-term enhancement of the endocannabinoid tone triggered augmented microglial activation and amyloid beta phagocytosis, and a consequent reversal in the neuronal phenotype associated to the diseasepost-print4206 K

    El Derecho del Trabajo y de la Seguridad Social en España en 2015. Sección Juvenil de la Asociación Española de Derecho del Trabajo y de la Seguridad Social.

    Get PDF
    Este Informe deja constancia de los cambios normativos más relevantes y de las tendencias judiciales más paradigmáticas del ordenamiento laboral en 2015. En él se observa el imparable dinamismo del Derecho del Trabajo y de la Seguridad Social en España. El documento, consciente de tal mutabilidad, recoge una minuciosa selección de cuestiones esenciales, a juicio de las personas que abordan cada una de las materias, de las que son especialistas; los autores y las autoras, que forman parte de la Sección Juvenil de la Asociación Española de Derecho del Trabajo y de la Seguridad Social, se adscriben a los grupos temáticos por afinidad con sus principales líneas de investigación y su labor docente universitaria. En síntesis, en el Informe “El Derecho del Trabajo y de la Seguridad Social en España en 2015” se puede encontrar información muy útil para los profesionales del iuslaboralismo en materia de derechos fundamentales inespecíficos, contratación laboral y empleo, vicisitudes del contrato de trabajo, derechos colectivos, igualdad y corresponsabilidad, Seguridad Social o prevención de riesgos laborales. This report has as aim leaving a record of the most relevant normative changes and the most paradigmatic judicial trends in Labour Law in 2015. One can easily observe the unstoppable dynamismof Labour and Social Security Law in Spain. The document, conscious of that mutability, collects a thorough selection of key issues, according to the judgement of the authors, all of them specialists and all of them members of the Young Scholars’ Section of the Spanish Association for Labour and Social Security Law. They are part of thematic groups, linked to their main research lines and their teaching task. Summing up, in this report “Labour and Social Security Law in Spain in 2015”, one can easily find useful information for labour lawyers in subjects such as unspecific fundamental rights, work contracts and employment, issues of the labour relationship, collective rights, equality and co-responsibility, Social Security or occupational risk prevention

    ¿Qué queda de mí?

    Get PDF
    Este libro es una reclamación a quienes hemos sido, somos o seremos docentes. A quienes no hemos respetado a las personas que se han puesto junto a nosotros y nosotras, confiando su bien más preciado: la libertad. Estas páginas denuncian cada vez que convertimos una visión en la visión, una emoción en la emoción, un saber en el saber, un comportamiento en el comportamiento. Es un grito contra la imposición, la normalización, la neutralización y la universalización de una perspectiva particular. Una pugna contra cada proceso que no se ha conectado con las vidas de los aprendices. Un texto colaborativo realizado por alumnado de Educación y Cambio Social en el Grado en Educación Infantil de la Universidad de Málaga y coordinado por Ignacio Calderón Almendros

    Mobilitzacions socials i esquerra radical : Actes del II Congrés Les altres protagonistes de la Transició Barcelona, 11 a 13 d'octubre de 2019

    Get PDF

    Silica Nanoparticle/Fluorescent Dye Assembly Capable of Ultrasensitively Detecting Airborne Triacetone Triperoxide: Proof-of-Concept Detection of Improvised Explosive Devices in the Workroom

    No full text
    We describe the proof of concept of a portable testing setup for the detection of triacetone triperoxide (TATP), a common component in improvised explosive devices. The system allows for field testing and generation of real-time results to test for TATP vapor traces in air by simply using circulation of the air samples through the sensing mechanism under the air conditioning system of an ordinary room. In this way, the controlled trapping of the analyte in the chemical sensor gives reliable results at extremely low concentrations of TATP in air under real-life conditions, suitable for daily use in luggage storage for airlines or a locker room for a major sporting event. The reported fluorescent methodology is very sensitive and selective, allowing for the trapping of triacetone triperoxide in the chemical sensor to give reliable results at very low concentrations in air under ambient conditions, by comparing the fluorescence of the material before and after exposition to TATP traces in air.This research was funded by the NATO Science for Peace and Security Programme (Grant SPS G5536) and the Ministerio de Ciencia e Innovación (Grants PID2019-111215RB-I00 and PDC2022-133955-I00). A.R.-C. thanks Secretaría General de Universidades for a FPU18/03225 Grant. The authors thank J. Rafael Santana-Tejada, from Movilmatica (www.movilmatica.com) for technical assistance with the preparation of the app

    Cell-mediated cytotoxicity is the main innate immune mechanism involved in the cellular defence of gilthead seabream (Teleostei: Sparidae) against Enteromyxum leei (Myxozoa)

    No full text
    The cellular innate immune response of gilthead seabream (Sparus aurata L.) against the myxozoan Enteromyxum leei was studied. Enteromyxosis was transmitted by maintaining uninfected fish (recipients) together with infected animals. A group of fish not exposed to the infection served as controls. After 10, 22, 38, 52 and 108 days, control and recipient fish were sampled and leucocyte subpopulations and cellular immune responses (leucocyte peroxidases, phagocytosis, respiratory burst and cytotoxicity) of the head-kidney leucocytes were determined. The percentage of acidophilic granulocytes was significantly lower in non-parasitized and parasitized recipient fish than in control fish after 22 days but no significant differences were seen between non-parasitized and parasitized recipient animals. The leucocyte peroxidase content, phagocytosis and respiratory burst activity were seen to have decreased significantly at different sampling times in both non-parasitized and parasitized recipient fish with respect to the controls, whereas cytotoxic activity was up to 2.3 times higher than in control fish. Within the recipient group, little difference was observed in the studied parameters between non-parasitized and parasitized fish. These data demonstrate that cytotoxic activity may have an important role in the defence of gilthead seabream against the myxosporean E. leei. Immunological implications of E. leei infections are discussed.This work has been funded by an EU Project (QLRT-2001-00722 MyxFishControl). A. Cuesta and I. Salinas are beneficiaries of Fundación CajaMurcia and Fundación Séneca fellowships, respectively

    Gilthead seabream (Sparus aurata L.) innate defence against the parasite Enteromyxum leei (Myxozoa)

    No full text
    The humoral innate immune response of gilthead seabream (Sparus aurata L.) against the myxozoan Enteromyxum leei has been studied. At 10, 22, 38, 52 and 108 days of cohabitation fish were sampled to examine gut histology and to determine serum innate immune parameters and the mRNA expression of pro-inflammatory cytokines (IL-1β and TNFα) in head-kidney. The parasite was successfully transmitted to 45% of the recipient fish and prevalence reached a maximum (62.5%) at the last sampling time (108 days). Recipient fish started to die after 74 days of cohabitation. In general, alternative complement activity was higher whereas the peroxidase level was lower in recipient fish than in controls. Moreover, IL-1β mRNA expression increased while the TNFα gene expression decreased in recipient fish. These data demonstrate the involvement of complement activity in the defence mechanisms of the gilthead seabream against the myxosporean E. leei. Within the recipient fish group, few differences were observed in the studied immune parameters between E. leei-parasitized and non-parasitized recipient fish. Parasitological and immunological implications of E. leei infections in Mediterranean fish farms are discussed.This work has been funded by an EU Project (QLRT2001-00722 MyxFishControl). A. C. and I. S. are beneficiaries of Fundación CajaMurcia and Fundación Séneca fellowships, respectively. Primers for cytokines were designed by Dr V. Mulero of the Fish Innate Immune System Group of the University of Murcia

    New fluorescent reporters capable of Ultra-sensitively detecting trinitrotoluene on surfaces: A proof-of-concept for finding hidden nitroaromatics in the workroom

    No full text
    We describe the proof of concept of a portable testing setup for the detection of trinitrotoluene (TNT), a common component in hidden explosive devices. The system allows for field-testing and generation of real-time results to test for TNT traces in surfaces by simply using a filter paper and a fluorescent reporter. In this way, the controlled trapping and detection of the analyte by a chemical sensor gives reliable results at extremely low concentrations of TNT on surfaces under real life conditions suitable for daily use in ordinary sampling for example at airlines luggage storage or sport locker rooms. The reported fluorescent methodology is very sensitive and selective, allowing for the trapping and detection of TNT by a fluorescent reporter to give reliable results at very low concentrations. As a complement, we report the preparation of a modified Sylgard film that is useful under real conditions for qualitative fluorescent detection of hidden traces of TNT on surfaces or fingers by a swab method. The combination of quantitative and qualitative detection of TNT traces on surfaces constitutes a comprehensive new method for the detection of hidden nitroaromatic explosives in the workplace.This research was funded by the NATO Science for Peace and Security Programme (Grant SPS G5536) and the Ministerio de Ciencia e Innovación (Grants PID2019-111215RB-I00 and PDC2022-133955-I00). A. R. C. thanks Secretaría General de Universidades for a FPU18/03225 Grant
    corecore