28 research outputs found
axial form factor from bubble chamber experiments
A careful reanalysis of both Argonne National Laboratory and Brookhaven
National Laboratory data for weak single pion production is done. We consider
deuteron nuclear effects and normalization (flux) uncertainties in both
experiments. We demonstrate that these two sets of data are in good agreement.
For the dipole parametrization of , we obtain , GeV. As an application we present the discussion of
the uncertainty of the neutral current 1 production cross section,
important for the T2K neutrino oscillation experiment.Comment: 16 pages, 8 figures, 2 table
Final State Interactions Effects in Neutrino-Nucleus Interactions
Final State Interactions effects are discussed in the context of Monte Carlo
simulations of neutrino-nucleus interactions. A role of Formation Time is
explained and several models describing this effect are compared. Various
observables which are sensitive to FSI effects are reviewed including
pion-nucleus interaction and hadron yields in backward hemisphere. NuWro Monte
Carlo neutrino event generator is described and its ability to understand
neutral current production data in GeV neutrino flux
experiments is demonstrated.Comment: 13 pages, 16 figure
The ICARUS T600 Experiment in the Gran Sasso Underground Laboratory
With a mass of about 600 tons of Liquid Argon (LAr), the ICARUS T600 detector is the biggest, up to now, LAr Time Projection Chamber (TPC). Following its successful test run, on the Earth surface, in Pavia (Italy) in 2001, the detector is now very close to start data taking in the Gran Sasso underground laboratory. The main features of the LAr TPC technique, together with a short discussion of some of the ICARUS T600 test run results, are presented in this paper
The T2K Side Muon Range Detector
The T2K experiment is a long baseline neutrino oscillation experiment aiming
to observe the appearance of {\nu} e in a {\nu}{\mu} beam. The {\nu}{\mu} beam
is produced at the Japan Proton Accelerator Research Complex (J-PARC), observed
with the 295 km distant Super- Kamiokande Detector and monitored by a suite of
near detectors at 280m from the proton target. The near detectors include a
magnetized off-axis detector (ND280) which measures the un-oscillated neutrino
flux and neutrino cross sections. The present paper describes the outermost
component of ND280 which is a side muon range detector (SMRD) composed of
scintillation counters with embedded wavelength shifting fibers and Multi-Pixel
Photon Counter read-out. The components, performance and response of the SMRD
are presented.Comment: 13 pages, 19 figures v2: fixed several typos; fixed reference
The degree of acute descending control of spinal nociception in an area of primary hyperalgesia is dependent on the peripheral domain of afferent input
Descending controls of spinal nociceptive processing play a critical role in the development of inflammatory hyperalgesia. Acute peripheral nociceptor sensitization drives spinal sensitization and activates spino–supraspinal–spinal loops leading to descending inhibitory and facilitatory controls of spinal neuronal activity that further modify the extent and degree of the pain state. The afferent inputs from hairy and glabrous skin are distinct with respect to both the profile of primary afferent classes and the degree of their peripheral sensitization. It is not known whether these differences in afferent input differentially engage descending control systems to different extents or in different ways. Injection of complete Freund's adjuvant resulted in inflammation and swelling of hairy hind foot skin in rats, a transient thermal hyperalgesia lasting 72 h). In hairy skin, transient hyperalgesia was associated with sensitization of withdrawal reflexes to thermal activation of either A- or C-nociceptors. The transience of the hyperalgesia was attributable to a rapidly engaged descending inhibitory noradrenergic mechanism, which affected withdrawal responses to both A- and C-nociceptor activation and this could be reversed by intrathecal administration of yohimbine (α-2-adrenoceptor antagonist). In glabrous skin, yohimbine had no effect on an equivalent thermal inflammatory hyperalgesia. We conclude that acute inflammation and peripheral nociceptor sensitization in hind foot hairy skin, but not glabrous skin, rapidly activates a descending inhibitory noradrenergic system. This may result from differences in the engagement of descending control systems following sensitization of different primary afferent classes that innervate glabrous and hairy skin
The SMRD subdetector at the T2K near detector station
The T2K long-baseline neutrino oscillation experiment is running in Japan. The primary goals of the T2K are measurement of the mixing angle 13, and precise measurements of the mixing angle 23 and of the mass difference m2 23. The installation of the near detector complex was completed and first data were already registered. This article presents operation of the Side Muon Range Detector, a component of the Off-Axis near detector. Detector concept and implementation are presented, followed by a description of cosmic muon track reconstruction algorithm and finally current status
Energy reconstruction of electromagnetic showers from [Pi 0] decays with the ICARUS T600 liquid argon TPC
We discuss the ICARUS T600 detector capabilities in electromagnetic shower reconstruction through the analysis of a sample of 212 events, coming from the 2001 Pavia surface test run, of hadronic interactions leading
to the production of 0 mesons. Methods of shower energy and shower direction measurements were developed and the invariant mass of the photon pairs was reconstructed. The ( ) invariant mass was found to be consistent
with the value of the 0 mass. The resolution of the reconstructed 0 mass was found to be equal to 27.3%. An improved analysis, carried out in order to clean the full event sample from the events measured in the
crowded environment, mostly due to the trigger conditions, gave a 0 mass resolution of 16.1%, significantly better than the one evaluated for the full event sample. The trigger requirement of the coincidence of at least four
photo-multiplier signals favored the selection of events with a strong pile up of cosmic ray tracks and interactions. Hence a number of candidate 0 events were heavily contaminated by other tracks and had to be rejected. Monte Carlo simulations of events with 0 production in hadronic and neutrino interactions confirmed the validity of the shower energy and shower direction reconstruction methods applied to the real data
Pion production uncertainty in context of Tokai2Kamioka (T2K) experiment
We evaluate uncertainty of the neutral current !0 production coming from li- mited knowledge of axial form-factor. The uncertainties of the form-factor pa- rameters are obtained from a self-consistent fit to the results of ANL and BNL experiments measuring pion production free of significant nuclear effects. The evaluated uncertainities are important for T2K background estimates
Photoelectronic measurement methods and the universal measurement system for precise parameter determination of semiconductor structures
In this article a new Multifunctional System for Photoelectric Measurements of Semiconductor Structures (MSPM) is presented. The system enables very accurate photocurrent measurements at levels as low as 10 fA. Measured structures can be biased by sequences of DC voltages and stimulated by light beams of predefined wavelengths and powers. The software controls all the system actions allowing flexibility in retrieving data stored in the related databases