13 research outputs found

    Toward a Generic Extraction Method for Simultaneous Deterimination of Pesticides, Mycotoxins, Plant Toxins and Veterinary Drugs in Feed and Food Matrixes

    No full text
    A fast and straightforward generic procedure for the simultaneous extraction of various classes of pesticides, mycotoxins, plant toxins, and veterinary drugs in various matrixes has been developed, for subsequent analysis by liquid chromatography with mass spectrometric detection. As a first step, four existing multianalyte procedures and three newly proposed methods were compared for a test set of 172 pesticides, mycotoxins, and plant toxins spiked to a feed matrix. The new procedures, which basically involved extraction/dilution of the sample with water and an acidified organic solvent (methanol, acetonitrile, or acetone), were most promising. The three new generic extraction methods were further tested for applicability to other matrixes (maize, honey, milk, egg, meat). Overall, the best recoveries were obtained for acetone, followed by acetonitrile. With respect to matrix effects, acetonitrile was the most favorable solvent and methanol was the worst. The occurrence of matrix effects decreased for the matrixes in the order of feed > maize > meat > milk > egg > honey. The extraction method selected as the default procedure (water/acetonitrile/1% formic acid) was also evaluated for applicability to multiple classes of veterinary drugs in all six matrixes, with satisfactory results. Finally, the generic extraction procedure was validated for 136 pesticides, 36 natural toxins, and 86 veterinary drugs in compound feed and honey at three levels (0.01, 0.02, and 0.05 mg/kg) using ultraperformance liquid chromatography tandem mass spectrometry (UPLC¿MS/MS) for analysis of the extracts. For over 80% of the analytes, recoveries were between 70 and 120% and precision (expressed as relative standard deviation) was mostly in the range of 5¿10% (except for feed at 0.01 mg/kg; adequate recoveries for 62% of the analytes). The limits of detection were fro

    Advanced treatment of urban wastewater by UV-C/free chlorine process: Micro-pollutants removal and effect of UV-C radiation on trihalomethanes formation

    No full text
    The effect of the UV-C/free chlorine (FC) process on the removal of contaminants of emerging concern (CECs) from real urban wastewater as well as the effect of UV-C radiation on the formation of trihalomethanes (THMs) compared to FC process alone was investigated. Unlike of FC process, UV-C/FC was really effective in the degradation of the target CECs (carbamazepine (CBZ), diclofenac, sulfamethoxazole and imidacloprid) in real wastewater (87% degradation of total CECs within 60 min, QUVC = 1.33 kJ L−1), being CBZ the most refractory one (49.5%, after 60 min). The UV-C radiation significantly affected the formation of THMs. THMs concentration (mainly chloroform) was lower in UV-C/FC process after 30 min treatment (<1 μgL−1 = limit of quantification (LOQ)) than in FC process in dark (2.3 μgL−1). Noteworthy, while in FC treated wastewater chloroform concentration increased after treatment, UV-C/FC process resulted in a significant decrease (residual concentrations below the LOQ), even after 24 h and 48 h post-treatment incubation. The formation of radicals due to UV-C/FC process can reduce THMs compared to chlorination process, because part of FC reacts with UV-C radiation to form radicals and it is no longer available to form THMs. These results are encouraging in terms of possible use of UV-C/FC process as advanced treatment of urban wastewater even for possible effluent reuse

    Effect of Overnight Staining on the Quality of Flow Cytometric Sorted Stallion Sperm: Comparison with Tradtitional Protocols

    No full text
    Flow cytometry is considered the only reliable method for the separation of X and Y chromosome bearing spermatozoa in equines. The MoFlo SX DP sorter is highly efficient, allowing the production of foals of the desired sex. However, to achieve acceptable pregnancy rates the currently used protocol requires working with fresh semen obtained close to, or at, the sorting facility. An alternative protocol was tested during two consecutive breeding seasons. Fresh stallion semen was cooled for 20 h, during which staining with Hoechst 33342 took place. On the following day, this sample was flow sorted and compared with spermatozoa from the same ejaculate that had been sexed on the previous day. All sperm parameters evaluated remained unchanged when fresh sorted and refrigerated sorted semen were compared. Pre-sorting storage at 5 degrees C did not alter sperm velocities nor kinetics, viability or membrane permeability, production of reactive oxygen species, mitochondrial membrane potential or DNA fragmentation index of the sorted sample. The findings open for the possibility of using semen from stallions housed far from the sorting facilities. Processed and stained sperm could be shipped refrigerated on the previous day, sorted and inseminated on the next day
    corecore