5,355 research outputs found

    Characterization of energy levels related to impurities in epitaxial 4H-SiC ion implanted p+n junctions

    Get PDF
    Abstract The distribution of energy levels within the bandgap of epitaxial 4H-SiC p + /n junctions was studied. The junction was obtained by Al ion implantation on a nitrogen doped n-type epitaxial substrate. Thermally stimulated currents/capacitance (TSC/TSCAP) as well as current/capacitance deep level transient spectroscopy (I- and C-DLTS) were carried out over a wide temperature range (20–400 K). The two TSC/DLTS peaks associated with N-doping were detected for the first time and their trap signatures determined. Two hole traps relating to deep and shallow boron confirm that a boron contamination occurred during crystal growth. A negligible concentration of the Z 1/2 level, which is usually the dominant level produced by irradiation of ion implant, was measured. The concentrations of all observed traps were significantly lower than nitrogen one, which determines the doping. This evidence supports the high quality of the processed junctions, making these devices particularly attractive for future use in particle detection as well as in optoelectronic applications

    Thermal donors formation via isothermal annealing in magnetic Czochralski high resistivity silicon

    Get PDF
    A quantitative study about the thermal activation of oxygen related thermal donors in high resistivity p-type magnetic Czochralski silicon has been carried out. Thermal donor formation has been performed through isothermal annealing at 430°C up to a total time of 120min. Space charge density after each annealing step has been measured by transient current technique. The localized energy levels related to thermal double donors (TD) have been observed and studied in details by thermally stimulated currents (TSCs) in the range of 10–70K, and activation energies E and effective cross sections σ have been determined for both the emissions TD0∕+ (E=75±5meV, σ=4×10−14cm2) and TD+∕+ (E=170±5meV, σ=2×10−12cm2). The evolution of the space charge density caused by annealing has been unambiguously related to the activation of TDs by means of current deep level transient spectroscopy TSC, and current transients at constant temperature i(t,T). Our results show that TDs compensate the initial boron doping, eventually provoking the sign inversion of the space charge density. TD's generation rate has been found to be linear with the annealing time and to depend critically on the initial interstitial oxygen concentration, in agreement with previous models developed on low resistivity silicon

    Dosimetric characterization with 62 MeV protons of a silicon-segmented detector for 2D dose verifications in radiotherapy

    Get PDF
    Abstract Due to the features of the modern radiotherapy techniques, namely intensity modulated radiation therapy and proton therapy, where high spatial dose gradients are often present, detectors to be employed for 2D dose verifications have to satisfy very narrow requirements. In particular they have to show high spatial resolution. In the framework of the European Integrated Project—Methods and Advanced Equipment for Simulation and Treatment in Radio-Oncology (MAESTRO, no. LSHC-CT-2004-503564), a dosimetric detector adequate for 2D pre-treatment dose verifications was developed. It is a modular detector, based on a monolithic silicon-segmented sensor, with an n-type implantation on an epitaxial p-type layer. Each pixel element is 2×2 mm 2 and the distance center-to-center is 3 mm. The sensor is composed of 21×21 pixels. In this paper, we report the dosimetric characterization of the system with a proton beam. The sensor was irradiated with 62 MeV protons for clinical treatments at INFN-Laboratori Nazionali del Sud (LNS) Catania. The studied parameters were repeatability of a same pixel, response linearity versus absorbed dose, and dose rate and dependence on field size. The obtained results are promising since the performances are within the project specifications

    PICTS analysis of extended defects in heavily irradiated silicon

    Get PDF
    We report the results of an experimental study on radiation-induced defects in silicon p/sup +/n diodes irradiated with 1-MeV neutrons up to a fluence of 2.3 /spl times/ 10/sup 15/ cm/sup -2/. Heavily irradiated silicon diodes have been studied by means of photo induced current transient spectroscopy (PICTS) technique using a variable filling time. For every filling time, a dominant broad and structured peak has been found in the temperature range 200-300 K. Such a broad peak cannot be accounted for by considering isolated point defects, being consistent with a quasi-continuous distribution of deep levels inside the bandgap. In addition, it is observed that the spectral lineshape tends to broaden as the filling time is increased. The details of the lineshape modifications depend strongly on the irradiation fluence of the sample, in such a way that they cannot be explained only in terms of emissions from noninteracting electron states. Thus we suggest that the investigated broad peak should, at least in part, be generated by emission from extended defects, also known as clusters

    2D dosimeter based on monolithic silicon sensors for beam verification in conformal radiotherapy

    Get PDF
    Due to the features of modern radiotherapy techniques, such as Intensity Modulated Radiation Therapy (IMRT), Stereotactic Treatments with photons and proton therapy, where high spatial dose gradient are often present, detectors to be employed for two-dimensional dose verifications must satisfy narrow requirements. In particular, they have to exhibit high spatial resolution. For these applications, in the framework of the European Integrated project MAESTRO (LSHC-CT-2004-503564) and of the INFN experiment PRIMA, we designed a modular system based on a monolithic silicon segmented sensor. A single sensor has been coupled with readout electronics and tested with satisfactory results by using 6, 10 and 25MV X-rays from a LINAC at the University Hospital of Florence and 62MeV protons at INFN LNS Catania, following MAESTRO procedures. For photons, almost all the channels exhibit performances within project specifications (repeatability ≪0.5%, reproducibility ≪1%, deviation from linearity ≪1%, dose rate dependence ≪1%). For protons, the measured Spread Out Bragg Peak is in good agreement with the one measured with a single diode and the detector shows also a good linearity in the range 20–5000 cGy. The output factors are in agreement with those measured with ionization chamber, single diode or film, within experimental errors

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    Constraints on the χ_(c1) versus χ_(c2) polarizations in proton-proton collisions at √s = 8 TeV

    Get PDF
    The polarizations of promptly produced χ_(c1) and χ_(c2) mesons are studied using data collected by the CMS experiment at the LHC, in proton-proton collisions at √s=8  TeV. The χ_c states are reconstructed via their radiative decays χ_c → J/ψγ, with the photons being measured through conversions to e⁺e⁻, which allows the two states to be well resolved. The polarizations are measured in the helicity frame, through the analysis of the χ_(c2) to χ_(c1) yield ratio as a function of the polar or azimuthal angle of the positive muon emitted in the J/ψ → μ⁺μ⁻ decay, in three bins of J/ψ transverse momentum. While no differences are seen between the two states in terms of azimuthal decay angle distributions, they are observed to have significantly different polar anisotropies. The measurement favors a scenario where at least one of the two states is strongly polarized along the helicity quantization axis, in agreement with nonrelativistic quantum chromodynamics predictions. This is the first measurement of significantly polarized quarkonia produced at high transverse momentum
    corecore