54 research outputs found

    Dense plasma focus PACO as a hard X-ray emitter: a study on the radiation source

    Get PDF
    The radiation in the X-ray range detected outside the vacuum chamber of the dense plasma focus (DPF) PACO, are produced on the anode zone. The zone of emission is studied in a shot-to-shot analysis, using pure deuterium as filling gas. We present a diagnostic method to determine the place and size of the hard X-ray source by image analysis of high density radiography plates.Fil: Supán, L.. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Exactas. Instituto de Fisica Arroyo Seco; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Tandil. Centro de Investigaciones en Física e Ingeniería del Centro de la Provincia de Buenos Aires; ArgentinaFil: Guichón, S.. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Exactas. Instituto de Fisica Arroyo Seco; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Tandil. Centro de Investigaciones en Física e Ingeniería del Centro de la Provincia de Buenos Aires; ArgentinaFil: Milanese, Maria Magdalena. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Exactas. Instituto de Fisica Arroyo Seco; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Tandil. Centro de Investigaciones en Física e Ingeniería del Centro de la Provincia de Buenos Aires; ArgentinaFil: Niedbalski, Jorge Julio. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Exactas. Instituto de Fisica Arroyo Seco; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Tandil. Centro de Investigaciones en Física e Ingeniería del Centro de la Provincia de Buenos Aires; ArgentinaFil: Moroso, Roberto Luis. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Exactas. Instituto de Fisica Arroyo Seco; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Tandil. Centro de Investigaciones en Física e Ingeniería del Centro de la Provincia de Buenos Aires; ArgentinaFil: Acuña, H.. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Mar del Plata. Instituto de Investigaciones Físicas de Mar del Plata; ArgentinaFil: Malamud, Florencia. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Mar del Plata. Instituto de Investigaciones Físicas de Mar del Plata; Argentin

    Defining Early Human NK Cell Developmental Stages in Primary and Secondary Lymphoid Tissues

    Get PDF
    A better understanding of human NK cell development in vivo is crucial to exploit NK cells for immunotherapy. Here, we identified seven distinctive NK cell developmental stages in bone marrow of single donors using 10-color flow cytometry and found that NK cell development is accompanied by early expression of stimulatory co-receptor CD244 in vivo. Further analysis of cord blood (CB), peripheral blood (PB), inguinal lymph node (inLN), liver lymph node (liLN) and spleen (SPL) samples showed diverse distributions of the NK cell developmental stages. In addition, distinctive expression profiles of early development marker CD33 and C-type lectin receptor NKG2A between the tissues, suggest that differential NK cell differentiation may take place at different anatomical locations. Differential expression of NKG2A and stimulatory receptors (e.g. NCR, NKG2D) within the different subsets of committed NK cells demonstrated the heterogeneity of the CD56brightCD16+/− and CD56dimCD16+ subsets within the different compartments and suggests that microenvironment may play a role in differential in situ development of the NK cell receptor repertoire of committed NK cells. Overall, differential in situ NK cell development and trafficking towards multiple tissues may give rise to a broad spectrum of mature NK cell subsets found within the human body

    Ototoxicity of cisplatin plus standard radiation therapy vs. accelerated radiation therapy in glioblastoma patients

    Full text link
    Purpose : To assess the effect of cisplatin (CDDP) plus concurrent radiation therapy on hearing loss. Methods : 451 patients with glioblastoma multiforme (GBM) were randomly assigned after surgery to: Arm A: Carmustine (BCNU) + standard radiation therapy (SRT); Arm B: BCNU + accelerated radiation therapy (ART: 160 cGy twice daily for 15 days); Arm C: CDDP + BCNU + SRT; or Arm D: CDDP + BCNU + ART. Patients on arms C and D received audiograms at baseline, and prior to the start of RT, and prior to cycles 3 and 6. Otologic toxicities were recorded at each visit. Results : 56% of patients had hearing loss at baseline. 13% and 50% of patients experienced worsening ototoxicity after 1 year of treatment in arms A and B vs. C and D, respectively, with 13% of those on arms C and D experiencing significant ototoxicity (≥ grade 3) at 6 months. Increasing age was associated with an increased risk of ototoxicity. Conclusions : Increased exposure to CDDP increases the risk of ototoxicity over time. Older patients are more susceptible to hearing loss with CDDP. The low proportion of patients with clinically significant ototoxicity suggests that baseline screening is unnecessary in GBM patients.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/43476/1/11060_2005_Article_9049.pd

    Hitomi (ASTRO-H) X-ray Astronomy Satellite

    Get PDF
    The Hitomi (ASTRO-H) mission is the sixth Japanese x-ray astronomy satellite developed by a large international collaboration, including Japan, USA, Canada, and Europe. The mission aimed to provide the highest energy resolution ever achieved at E  >  2  keV, using a microcalorimeter instrument, and to cover a wide energy range spanning four decades in energy from soft x-rays to gamma rays. After a successful launch on February 17, 2016, the spacecraft lost its function on March 26, 2016, but the commissioning phase for about a month provided valuable information on the onboard instruments and the spacecraft system, including astrophysical results obtained from first light observations. The paper describes the Hitomi (ASTRO-H) mission, its capabilities, the initial operation, and the instruments/spacecraft performances confirmed during the commissioning operations for about a month

    Dispositivo Plasma Focus como fuente pulsada de neutrones de fusión D-D para identificación de nucleidos por activación neutrónica: primeros resultados

    No full text
    La activación por captura neutrónica de núcleos atómicos componentes de sustancias y el subsiguiente registro del espectro de radiación gamma instantánea y/o de decaimiento temprano característico emitida por los mismos, constituye una técnica de análisis no destructivo y extremadamente sensible que posibilita tanto identificarlos como determinarlos cuantitativamente. Para esta finalidad, se requiere irradiarlos con haces de neutrones cuyas energías estén típicamente comprendidas en los rangos térmicos y epitérmicos. Para un gran número de nucleidos y sus correspondientes isótopos estos rangos energéticos permiten maximizar la sección eficaz de captura nuclear. En la práctica, se recurre corrientemente al empleo de fuentes de neutrones constituidas por radioisótopos (naturales y artificiales) de relativamente alta actividad y largo tiempo de vida de decaimiento (226Ra-9Be, 252Cf, etc), que son difícilmente asequibles y de manipulación peligrosa o bien a instalaciones que por sus dimensiones físicas y complejidad estructural resultan de imposible traslado (reactores nucleares de investigación, aceleradores de partículas, etc.). En esta comunicación se presentan primeros resultados del empleo de un dispositivo plasma focus de relativamente baja energía operativa (2kJ, 31kV) como fuente generadora y transportable de haces de neutrones de fusión D-D (2.45 MeV) para el análisis de sustancias "in situ" por activación. Se muestra un simple espectro conteniendo la línea de emisión característica de 446.8 keV del isótopo 110Ag resultante de la reacción nuclear 109Ag(n,e,neutrino, gamma)110Ag que es activada por irradiación de una muestra de Ag natural con neutrones moderados producidos a partir de los energéticos que proporciona el dispositivo plasma focus. La emisión es registrada mediante un sistema convencional para espectroscopía gamma basado en un cristal de NaI(Tl)-Fotomultiplicador acoplado a un circuito amplificador y de adquisición de datos multicanal controlado por software.Fil: Milanese, Maria Magdalena. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Exactas. Instituto de Física Arroyo Seco; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tandil; ArgentinaFil: Niedbalski, Jorge Julio. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Exactas. Instituto de Física Arroyo Seco; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tandil; ArgentinaFil: Moroso, Roberto Luis. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Exactas. Instituto de Física Arroyo Seco; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tandil; ArgentinaFil: Barbaglia, M.. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Exactas. Instituto de Física Arroyo Seco; ArgentinaFil: Mayer, R.. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Exactas. Instituto de Física Arroyo Seco; ArgentinaFil: Supán, L.. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Exactas. Instituto de Física Arroyo Seco; ArgentinaFil: Guichon, Santiago. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Exactas. Instituto de Física Arroyo Seco; Argentin
    corecore