2,220 research outputs found
Multiple Quantum Well AlGaAs Nanowires
This letter reports on the growth, structure and luminescent properties of
individual multiple quantum well (MQW) AlGaAs nanowires (NWs). The composition
modulations (MQWs) are obtained by alternating the elemental flux of Al and Ga
during the molecular beam epitaxy growth of the AlGaAs wire on GaAs (111)B
substrates. Transmission electron microscopy and energy dispersive X-ray
spectroscopy performed on individual NWs are consistent with a configuration
composed of conical segments stacked along the NW axis. Micro-photoluminescence
measurements and confocal microscopy showed enhanced light emission from the
MQW NWs as compared to non-segmented NWs due to carrier confinement and
sidewall passivation
Anisotropic Hall Effect in Single Crystal Heavy Fermion YbAgGe
Temperature- and field-dependent Hall effect measurements are reported for
YbAgGe, a heavy fermion compound exhibiting a field-induced quantum phase
transition, and for two other closely related members of the RAgGe series: a
non-magnetic analogue, LuAgGe and a representative, ''good local moment'',
magnetic material, TmAgGe. Whereas the temperature dependent Hall coefficient
of YbAgGe shows behavior similar to what has been observed in a number of heavy
fermion compounds, the low temperature, field-dependent measurements reveal
well defined, sudden changes with applied field; in specific for a
clear local maximum that sharpens as temperature is reduced below 2 K and that
approaches a value of 45 kOe - a value that has been proposed as the
quantum critical point. Similar behavior was observed for where a
clear minimum in the field-dependent Hall resistivity was observed at low
temperatures. Although at our base temperatures it is difficult to distinguish
between the field-dependent behavior predicted for (i) diffraction off a
critical spin density wave or (ii) breakdown in the composite nature of the
heavy electron, for both field directions there is a distinct temperature
dependence of a feature that can clearly be associated with a field-induced
quantum critical point at persisting up to at least 2 K.Comment: revised versio
A Calibrated Time Domain Envelope Measurement System for the Behavioral Modeling of Power Amplifiers
This paper presents a set-up which enables the generation and the calibrated time domain measurements of complex envelopes of modulated signals at both ports of non linear microwave power amplifiers. The architecture of the characterization tool is given. Examples of error corrected time domain envelopes at the input / output RF ports of a 36 dBm output power – 30dB power gain L-band SSPA are shown. Futhermore, the use of this characterization tool and a suitable processing of measurement data are applied to a novel measurement based behavioral modeling approach of non linear devices accounting for memory effects
Visible light reduces C. elegans longevity.
The transparent nematode Caenorhabditis elegans can sense UV and blue-violet light to alter behavior. Because high-dose UV and blue-violet light are not a common feature outside of the laboratory setting, we asked what role, if any, could low-intensity visible light play in C. elegans physiology and longevity. Here, we show that C. elegans lifespan is inversely correlated to the time worms were exposed to visible light. While circadian control, lite-1 and tax-2 do not contribute to the lifespan reduction, we demonstrate that visible light creates photooxidative stress along with a general unfolded-protein response that decreases the lifespan. Finally, we find that long-lived mutants are more resistant to light stress, as well as wild-type worms supplemented pharmacologically with antioxidants. This study reveals that transparent nematodes are sensitive to visible light radiation and highlights the need to standardize methods for controlling the unrecognized biased effect of light during lifespan studies in laboratory conditions
First direct mass-measurement of the two-neutron halo nucleus 6He and improved mass for the four-neutron halo 8He
The first direct mass-measurement of He has been performed with the
TITAN Penning trap mass spectrometer at the ISAC facility. In addition, the
mass of He was determined with improved precision over our previous
measurement. The obtained masses are (He) = 6.018 885 883(57) u and
(He) = 8.033 934 44(11) u. The He value shows a deviation from
the literature of 4. With these new mass values and the previously
measured atomic isotope shifts we obtain charge radii of 2.060(8) fm and
1.959(16) fm for He and He respectively. We present a detailed
comparison to nuclear theory for He, including new hyperspherical harmonics
results. A correlation plot of the point-proton radius with the two-neutron
separation energy demonstrates clearly the importance of three-nucleon forces.Comment: 4 pages, 2 figure
Trapped-ion decay spectroscopy towards the determination of ground-state components of double-beta decay matrix elements
A new technique has been developed at TRIUMF's TITAN facility to perform
in-trap decay spectroscopy. The aim of this technique is to eventually measure
weak electron capture branching ratios (ECBRs) and by this to consequently
determine GT matrix elements of decaying nuclei. These branching
ratios provide important input to the theoretical description of these decays.
The feasibility and power of the technique is demonstrated by measuring the
ECBR of Cs.Comment: 9 pages, 9 figure
Dengue una enfermedad emergente y re-emergente en América
El Dengue es una enfermedad infecciosa, producida por un arbovirus cuyo único reservorio es el hombre. El virusutiliza como vector biológico al mosquito Aedes aegypti o al mosquito Aedes albopictus. La sintomatología se presentahabitualmente como un cuadro febril denominado dengue clásico, que se caracteriza por fiebre alta de presentaciónaguda, de duración limitada (2 a 7 días), con intenso malestar general, acompañado de erupción cutánea. Puedepresentar síntomas hemorrágicos de escasa intensidad, como petequias y sangramiento gingival. El tratamiento essintomático y el paciente mejora completamente en aproximadamente 7 días. Esta forma de dengue no producemortalidad. Sin embargo, existen otras presentaciones de la enfermedad que pueden llegar a manifestaciones graves deltipo hemorrágicas con muerte, lo que se presenta en el 5% de los enfermos. El dengue es un problema creciente desalud pública, que afecta a más de 100 países en el mundo, con más de 50 millones de casos informados cada año. Loscuatro tipos de dengue, están circulando en América, donde los casos aumentaron en los últimos años en formaexplosiva. Si bien, en Chile continental no se ha documentado la existencia del mosquito vector del dengue de formaendémica, si se ha hecho en Chile Insular, más específicamente en Isla de Pascua, donde desde el año 1999, seincorporó a la lista de enfermedades de declaración obligatoria (D.S. Nº 158) estableciendo su vigilancia. Los factoresque han llevado a la emergencia de esta enfermedad son principalmente el cambio climático, que ha modificado elnicho ecológico de los mosquitos de la familia Aedes. También la urbanización, la falta de control del vector, las fallasen infraestructura básica y el pobre saneamiento ambiental. La intervención primaria de salud pública ha ido por la líneadel uso de insecticidas para el control del vector y la detección temprana de casos. No existe aún una vacuna efectiva,sin embargo, actualmente se están realizando esfuerzos en esta materia
Coarctation of the aorta: pre and postoperative evaluation with MRI and MR angiography; correlation with echocardiography and surgery
Aims: To compare MRI and MRA with Doppler-echocardiography (DE) in native and postoperative aortic coarctation, define the best MR protocol for its evaluation, compare MR with surgical findings in native coarctation. Materials and methods: 136 MR studies were performed in 121 patients divided in two groups: Group I, 55 preoperative; group II, 81 postoperative. In group I, all had DE and surgery was performed in 35 cases. In group II, DE was available for comparison in 71 cases. MR study comprised: spin-echo, cine, velocity-encoded cine (VEC) sequences and 3D contrast-enhanced MRA. Results: In group I, diagnosis of coarctation was made by DE in 33 cases and suspicion of coarctation and/or aortic arch hypoplasia in 18 cases. Aortic arch was not well demonstrated in 3 cases and DE missed one case. There was a close correlation between VEC MRI and Doppler gradient estimates across the coarctation, between MRI aortic arch diameters and surgery but a poor correlation in isthmic measurements. In group II, DE detected a normal isthmic region in 31 out of 35 cases. Postoperative anomalies (recoarctation, aortic arch hypoplasia, kinking, pseudoaneurysm) were not demonstrated with DE in 50% of cases. Conclusions: MRI is superior to DE for pre and post-treatment evaluation of aortic coarctation. An optimal MR protocol is proposed. Internal measurement of the narrowing does not correspond to the external aspect of the surgical narrowin
- …
