21 research outputs found
Implementing screening for myocardial injury in non-cardiac surgery: perspectives of an ad-hoc interdisciplinary expert group
Objectives. Perioperative myocardial injury (PMI) is increasingly recognised as an important complication of non-cardiac surgery, with often clinically silent presentation, but detrimental prognosis. Active screening for PMI, involving the detection of dynamic and elevated levels of cardiac troponin, has recently been advocated by an increasing number of guidelines; however, active PMI screening has not been reflected in clinical practice. Design. As consensus on a common screening and management pathway is lacking, we synthesise the current evidence to provide suggestions on the selection of patients for screening, organisation of a screening program, and a potential management pathway, building upon a recently published perioperative screening algorithm. Results. Screening should be performed using high-sensitivity assays both preoperatively and postoperatively (postoperative Days 1 and 2) in patients at high-risk of experiencing perioperative complications. Conclusion. This expert opinion piece by an interdisciplinary group of predominantly Norwegian clinicians aims to assist healthcare professionals planning to implement guideline-recommended PMI screening at a local level in order to improve patient outcomes following non-cardiac surgery.publishedVersio
The relationship between workload and exercise-induced cardiac troponin elevations is influenced by non-obstructive coronary atherosclerosis
The relationship between exercise-induced troponin elevation and non-obstructive coronary artery disease (CAD) is unclear. This observational study assessed non-obstructive CAD's impact on exercise-induced cardiac Troponin I (cTnI) elevation in middle-aged recreational athletes. cTnI levels of 40 well-trained recreational athletes (73% males, 50 ± 9 years old) were assessed by a high-sensitive cTnI assay 24 h before, and at 3 and 24 h following two high-intensity exercises of different durations; a cardiopulmonary exercise test (CPET), and a 91-km mountain bike race. Workload was measured with power meters. Coronary computed tomography angiography was used to determine the presence or absence of non-obstructive (<50% obstruction) CAD. A total of 15 individuals had non-obstructive CAD (Atherosclerotic group), whereas 25 had no atherosclerosis (normal). There were higher post-exercise cTnI levels following the race compared with CPET, both at 3 h (77.0 (35.3–112.4) ng/L vs. 11.6 (6.4–22.5) ng/L, p < 0.001) and at 24 h (14.7 (6.7–16.3) vs. 5.0 (2.6–8.9) ng/L, p < 0.001). Absolute cTnI values did not differ among groups. Still, the association of cTnI response to power output was significantly stronger in the CAD versus Normal group both at 3 h post-exercise (Rho = 0.80, p < 0.001 vs. Rho = −0.20, p = 0.33) and 24-h post-exercise (Rho = 0.87, p < 0.001 vs. Rho = −0.13, p = 0.55). Exercise-induced cTnI elevation was strongly correlated with exercise workload in middle-aged athletes with non-obstructive CAD but not in individuals without CAD. This finding suggests that CAD influences the relationship between exercise workload and the cTnI response even without coronary artery obstruction.publishedVersio
Antibody-mediated interferences affecting cardiac troponin assays:recommendations from the IFCC Committee on Clinical Applications of Cardiac Biomarkers
The International Federation of Clinical Chemistry Committee on Clinical Applications of Cardiac Biomarkers (IFCC C-CB) provides educational documents to facilitate the interpretation and use of cardiac biomarkers in clinical laboratories and practice. Our aim is to improve the understanding of certain key analytical and clinical aspects of cardiac biomarkers and how these may interplay. Measurements of cardiac troponin (cTn) have a prominent place in the clinical work-up of patients with suspected acute coronary syndrome. It is therefore important that clinical laboratories know how to recognize and assess analytical issues. Two emerging analytical issues resulting in falsely high cTn concentrations, often several fold higher than the upper reference limit (URL), are antibody-mediated assay interference due to long-lived cTn-antibody complexes, called macrotroponin, and crosslinking antibodies that are frequently referred to as heterophilic antibodies. We provide an overview of antibody-mediated cTn assay interference and provide recommendations on how to confirm the interference and interpret the results
Assay precision and risk of misclassification at rule-out cut-offs for high-sensitivity cardiac troponin
Clinical trials and guidelines support the use of very low high-sensitivity cardiac troponin (hs-cTn) results to rule-out a myocardial infarction (MI) ( 1) ). The International Federation of Clinical Chemistry and Laboratory Medicine Committee on Clinical Applications of Cardiac Biomarkers committee, through a modeling approach, suggests assays need to have a lower limit near 3 ng/L and an analytical variation of 10% below 7 ng/L if these low values are to perform consistently in practice ( 2) ). Our objectives for the present study were to assess: i) if any type of instrument or individual instrument could achieve a coefficient of variation (CV) of ≤10% at very low hs-cTn cut-offs (i.e., targets) recommended in clinical pathways; ii) the frequency of results at the hs-cTn target, above the target and below the target, with the latter group representing potential misclassification to the low risk group where the target level would in the intermediate risk range.<br/
Determinants of interindividual variation in exercise-induced cardiac troponin i levels
Background
Postexercise cardiac troponin levels show considerable interindividual variations. This study aimed to identify the major determinants of this postexercise variation in cardiac troponin I (cTnI) following 3 episodes of prolonged high‐intensity endurance exercise.
Methods and Results
Study subjects were recruited among prior participants in a study of recreational cyclists completing a 91‐km mountain bike race in either 2013 or 2014 (first race). In 2018, study participants completed a cardiopulmonary exercise test 2 to 3 weeks before renewed participation in the same race (second race). Blood was sampled before and at 3 and 24 hours following all exercises. Blood samples were analyzed using the same Abbot high‐sensitivity cTnI STAT assay. Fifty‐nine individuals (aged 50±9 years, 13 women) without cardiovascular disease were included. Troponin values were lowest before, highest at 3 hours, and declining at 24 hours. The largest cTnI difference was at 3 hours following exercise between the most (first race) (cTnI: 200 [87–300] ng/L) and the least strenuous exercise (cardiopulmonary exercise test) (cTnI: 12 [7–23] ng/L; P<0.001). The strongest correlation between troponin values at corresponding times was before exercise (r=0.92, P<0.0001). The strongest correlations at 3 hours were between the 2 races (r=0.72, P<0.001) and at 24 hours between the cardiopulmonary exercise test and the second race (r=0.83, P<0.001). Participants with the highest or lowest cTnI levels showed no differences in race performance or baseline echocardiographic parameters.
Conclusions
The variation in exercise‐induced cTnI elevation is largely determined by a unique individual cTnI response that is dependent on the duration of high‐intensity exercise and the timing of cTnI sampling.publishedVersio
Could accreditation bodies facilitate the implementation of medical guidelines in laboratories?
Several studies have shown that recommendations related to how laboratory testing should be performed and results interpreted are limited in medical guidelines and that the uptake and implementation of the recommendations that are available need improvement. The EFLM/UEMS Working Group on Guidelines conducted a survey amongst the national societies for clinical chemistry in Europe regarding development of laboratory-related guidelines. The results showed that most countries have guidelines that are specifically related to laboratory testing; however, not all countries have a formal procedure for accepting such guidelines and few countries have guideline committees. Based on this, the EFLM/UEMS Working Group on Guidelines conclude that there is still room for improvement regarding these processes in Europe and raise the question if the accreditation bodies could be a facilitator for an improvement