142 research outputs found

    Stable fixation of an osseointegated implant system for above-the-knee amputees: titel RSA and radiographic evaluation of migration and bone remodeling in 55 cases.

    Get PDF
    Background and purposeRehabilitation of patients with transfemoral amputations is particularly difficult due to problems in using standard socket prostheses. We wanted to assess long-term fixation of the osseointegrated implant system (OPRA) using radiostereometric analysis (RSA) and periprosthetic bone remodeling.Methods51 patients with transfemoral amputations (55 implants) were enrolled in an RSA study. RSA and plain radiographs were scheduled at 6 months and at 1, 2, 5, 7, and 10 years after surgery. RSA films were analyzed using UmRSA software. Plain radiographs were graded for bone resorption, cancellization, cortical thinning, and trabecular streaming or buttressing in specifically defined zones around the implant.ResultsAt 5 years, the median (SE) migration of the implant was -0.02 (0.06) mm distally. The rotational movement was 0.42 (0.32) degrees around the longitudinal axis. There was no statistically significant difference in median rotation or migration at any follow-up time. Cancellization of the cortex (plain radiographic grading) appeared in at least 1 zone in over half of the patients at 2 years. However, the prevalence of cancellization had decreased by the 5-year follow-up.InterpretationThe RSA analysis for the OPRA system indicated stable fixation of the implant. The periprosthetic bone remodeling showed similarities with changes seen around uncemented hip stems. The OPRA system is a new and promising approach for addressing the challenges faced by patients with transfemoral amputations

    Person-centred care compared with standardized care for patients undergoing total hip arthroplasty—a quasi-experimental study

    Get PDF
    BACKGROUND: A common approach to decrease length of stay has been to standardize patient care, for example, by implementing clinical care pathways or creating fast-track organizations. In a recent national report, it was found that Sweden’s healthcare system often fails to anticipate and respond to patients as individuals with particular needs, values and preferences. We compared a standardized care approach to one of person-centred care for patients undergoing total hip replacement surgery. METHODS: A control group (n =138) was consecutively recruited between 20th September 2010 and 1st March 2011 and an intervention group (n =128) between 12th December 2011 and 12th November 2012, both scheduled for total hip replacement. The primary outcome measures were length of stay and physical function at both discharge and 3 months later. RESULTS: The mean length of stay in the control group was 7 days (SD 5.0) compared to 5.3 days in the intervention group (SD 2.2). Physical functional performance, as assessed using activities of daily living, was similar at baseline for both groups. At discharge, 84% in the control group had regained activities of daily living level A vs. 72% in the intervention group. At 3 months after surgery, 88% in the control group had regained their independence vs. 92.5% in the person-centred care group. CONCLUSIONS: Focusing attention on patients as people and including them as partners in healthcare decision-making can result in shorter length of stay. The present study shows that the patients should be the focus and they should be involved as partners

    Outcome in design-specific comparisons between highly crosslinked and conventional polyethylene in total hip arthroplasty

    Get PDF
    <p>Background and purpose — Most registry studies regarding highly crosslinked polyethylene (XLPE) have focused on the overall revision risk. We compared the risk of cup and/or liner revision for specific cup and liner designs made of either XLPE or conventional polyethylene (CPE), regarding revision for any reason and revision due to aseptic loosening and/or osteolysis.</p> <p>Patients and methods — Using the Nordic Arthroplasty Register Association (NARA) database, we identified cup and liner designs where either XLPE or CPE had been used in more than 500 THAs performed for primary hip osteoarthritis. We assessed risk of revision for any reason and for aseptic loosening using Cox regression adjusted for age, sex, femoral head material and size, surgical approach, stem fixation, and presence of hydroxyapatite coating (uncemented cups).</p> <p>Results — The CPE version of the ZCA cup had a risk of revision for any reason similar to that of the XLPE version (p = 0.09), but showed a 6-fold higher risk of revision for aseptic loosening (p < 0.001). The CPE version of the Reflection All Poly cup had an 8-fold elevated risk of revision for any reason (p < 0.001) and a 5-fold increased risk of revision for aseptic loosening (p < 0.001). The Charnley Elite Ogee/Marathon cup and the Trilogy cup did not show such differences.</p> <p>Interpretation — Whether XLPE has any advantage over CPE regarding revision risk may depend on the properties of the polyethylene materials being compared, as well as the respective cup designs, fixation type, and follow-up times. Further research is needed to elucidate how cup design factors interact with polyethylene type to affect the risk of revision.</p

    Validation of inertial measurement units with optical tracking system in patients operated with Total hip arthroplasty

    Get PDF
    Patient reported outcome measurement (PROMs) will not capture in detail the functional joint motion before and after total hip arthroplasty (THA). Therefore, methods more specifically aimed to analyse joint movements may be of interest. An analysis method that addresses these issues should be readily accessible and easy to use especially if applied to large groups of patients, who you want to study both before and after a surgical intervention such as THA. Our aim was to evaluate the accuracy of inertial measurement units (IMU) by comparison with an optical tracking system (OTS) to record pelvic tilt, hip and knee flexion in patients who had undergone THA.This article is freely available via Open Access. Click on the Publisher's URL to access the full-text

    Hydroxyapatite coating does not improve uncemented stem survival after total hip arthroplasty!: An analysis of 116,069 THAs in the Nordic Arthroplasty Register Association (NARA) database

    Get PDF
    Background and purpose — It is still being debated whether HA coating of uncemented stems used in total hip arthroplasty (THA) improves implant survival. We therefore investigated different uncemented stem brands, with and without HA coating, regarding early and long-term survival. Patients and methods — We identified 152,410 THA procedures using uncemented stems that were performed between 1995 and 2011 and registered in the Nordic Arthroplasty Register Association (NARA) database. We excluded 19,446 procedures that used stem brands less than 500 times in each country, procedures performed due to diagnoses other than osteoarthritis or pediatric hip disease, and procedures with missing information on the type of coating. 22 stem brands remained (which were used in 116,069 procedures) for analysis of revision of any component. 79,192 procedures from Denmark, Norway, and Sweden were analyzed for the endpoint stem revision. Unadjusted survival rates were calculated according to Kaplan-Meier, and Cox proportional hazards models were fitted in order to calculate hazard ratios (HRs) for the risk of revision with 95% confidence intervals (CIs). Results — Unadjusted 10-year survival with the endpoint revision of any component for any reason was 92.1% (CI: 91.8–92.4). Unadjusted 10-year survival with the endpoint stem revision due to aseptic loosening varied between the stem brands investigated and ranged from 96.7% (CI: 94.4–99.0) to 99.9% (CI: 99.6–100). Of the stem brands with the best survival, stems with and without HA coating were found. The presence of HA coating was not associated with statistically significant effects on the adjusted risk of stem revision due to aseptic loosening, with an HR of 0.8 (CI: 0.5–1.3; p = 0.4). The adjusted risk of revision due to infection was similar in the groups of THAs using HA-coated and non-HA-coated stems, with an HR of 0.9 (CI: 0.8–1.1; p = 0.6) for the presence of HA coating. The commonly used Bimetric stem (n = 25,329) was available both with and without HA coating, and the adjusted risk of stem revision due to aseptic loosening was similar for the 2 variants, with an HR of 0.9 (CI: 0.5–1.4; p = 0.5) for the HA-coated Bimetric stem. Interpretation — Uncemented HA-coated stems had similar results to those of uncemented stems with porous coating or rough sand-blasted stems. The use of HA coating on stems available both with and without this surface treatment had no clinically relevant effect on their outcome, and we thus question whether HA coating adds any value to well-functioning stem designs.publishedVersio

    Total hip arthroplasties in the Dutch Arthroplasty Register (LROI) and the Nordic Arthroplasty Register Association (NARA): comparison of patient and procedure characteristics in 475,685 cases

    Get PDF
    Background and purpose — Collaborations between arthroplasty registries are important in order to create the possibility of detecting inferior implants early and improve our understanding of differences between nations in terms of indications and outcomes. In this registry study we compared patient and procedure characteristics, and revision rates in the Nordic Arthroplasty Register Association (NARA) database and the Dutch Arthroplasty Register (LROI). Patients and methods — All total hip arthroplasties (THAs) performed in 2010–2016 were included from the LROI (n = 184,862) and the NARA database (n = 290,823), which contains data from Denmark, Norway, Sweden, and Finland. Descriptive statistics and Kaplan–Meier survival analyses based on all reasons for revision and stratified by fixation were performed and compared between countries. Results — In the Netherlands, the proportion of patients aged < 55 years (9%) and male patients (34%) was lower than in Nordic countries (< 55 years 11–13%; males 35–43%); the proportion of osteoarthritis (OA) (87%) was higher compared with Sweden (81%), Norway (77%), and Denmark (81%) but comparable to Finland (86%). Uncemented fixation was used in 62% of patients in the Netherlands, in 70% of patients in Denmark and Finland, and in 28% and 19% in Norway and Sweden, respectively. The 5-year revision rate for THAs for OA was lower in Sweden (2.3%, 95% CI 2.1–2.5) than in the Netherlands (3.0%, CI 2.9–3.1), Norway (3.8%, CI 3.6–4.0), Denmark (4.6%, CI 4.4–4.8), and Finland (4.4%, CI 4.3–4.5). Revision rates in Denmark, Norway, and Finland were higher for all fixation groups. Interpretation — Patient and THA procedure characteristics as well as revision rates evinced some differences between the Netherlands and the Nordic countries. The Netherlands compared best with Denmark in terms of patient and procedure characteristics, but resembled Sweden more in terms of short-term revision risk. Combining data from registries like LROI and the NARA collaboration is feasible and might possibly enable tracking of potential outlier implants.publishedVersio

    Countrywise results of total hip replacement. An analysis of 438,733 hips based on the Nordic Arthroplasty Register Association database

    Get PDF
    Background and purpose: An earlier Nordic Arthroplasty Register Association (NARA) report on 280,201 total hip replacements (THRs) based on data from 1995–2006, from Sweden, Norway, and Denmark, was published in 2009. The present study assessed THR survival according to country, based on the NARA database with the Finnish data included. Material and methods: 438,733 THRs performed during the period 1995–2011 in Sweden, Denmark, Norway, and Finland were included. Kaplan-Meier survival analysis was used to calculate survival probabilities with 95% confidence interval (CI). Cox multiple regression, with adjustment for age, sex, and diagnosis, was used to analyze implant survival with revision for any reason as endpoint. Results: The 15-year survival, with any revision as an endpoint, for all THRs was 86% (CI: 85.7–86.9) in Denmark, 88% (CI: 87.6–88.3) in Sweden, 87% (CI: 86.4–87.4) in Norway, and 84% (CI: 82.9–84.1) in Finland. Revision risk for all THRs was less in Sweden than in the 3 other countries during the first 5 years. However, revision risk for uncemented THR was less in Denmark than in Sweden during the sixth (HR = 0.53, CI: 0.34–0.82), seventh (HR = 0.60, CI: 0.37–0.97), and ninth (HR = 0.59, CI: 0.36–0.98) year of follow-up. Interpretation: The differences in THR survival rates were considerable, with inferior results in Finland. Brand-level comparison of THRs in Nordic countries will be required
    • …
    corecore