58 research outputs found

    Assessment of exposure determinants and exposure levels by using stationary concentration measurements and a probabilistic near-field/far-field exposure model

    Get PDF
    Background: The Registration, Evaluation, Authorization and Restriction of Chemicals (REACH) regulation requires the establishment of Conditions of Use (CoU) for all exposure scenarios to ensure good communication of safe working practices. Setting CoU requires the risk assessment of all relevant Contributing Scenarios (CSs) in the exposure scenario. A new CS has to be created whenever an Operational Condition (OC) is changed, resulting in an excessive number of exposure assessments. An efficient solution is to quantify OC concentrations and to identify reasonable worst-case scenarios with probabilistic exposure modeling. Methods: Here, we appoint CoU for powder pouring during the industrial manufacturing of a paint batch by quantifying OC exposure levels and exposure determinants. The quantification was performed by using stationary measurements and a probabilistic Near-Field/Far-Field (NF/FF) exposure model. Work shift and OC concentration levels were quantified for pouring TiO 2 from big bags and small bags, pouring Micro Mica from small bags, and cleaning. The impact of exposure determinants on NF concentration level was quantified by (1) assessing exposure determinants correlation with the NF exposure level and (2) by performing simulations with different OCs. Results: Emission rate, air mixing between NF and FF and local ventilation were the most relevant exposure determinants affecting NF concentrations. Potentially risky OCs were identified by performing Reasonable Worst Case (RWC) simulations and by comparing the exposure 95 th percentile distribution with 10% of the occupational exposure limit value (OELV). The CS was shown safe except in RWC scenario (ventilation rate from 0.4 to 1.6 1/h, 100 m 3 room, no local ventilation, and NF ventilation of 1.6 m 3/min). Conclusions: The CoU assessment was considered to comply with European Chemicals Agency (ECHA) legislation and EN 689 exposure assessment strategy for testing compliance with OEL values. One RWC scenario would require measurements since the exposure level was 12.5% of the OELV

    Assessment of exposure determinants and exposure levels by using stationary concentration measurements and a probabilistic near-field/far-field exposure model

    Get PDF
    Funding Information: The authors thank Prof. Paul Hewett (Exposure Assessment Solutions, Inc., Morgantown, WV) for his assistance with revising the probabilistic exposure model parametrization and interpretation of the results. Publisher Copyright: © 2021 Koivisto AJ et al.Background: The Registration, Evaluation, Authorization and Restriction of Chemicals (REACH) regulation requires the establishment of Conditions of Use (CoU) for all exposure scenarios to ensure good communication of safe working practices. Setting CoU requires the risk assessment of all relevant Contributing Scenarios (CSs) in the exposure scenario. A new CS has to be created whenever an Operational Condition (OC) is changed, resulting in an excessive number of exposure assessments. An efficient solution is to quantify OC concentrations and to identify reasonable worst-case scenarios with probabilistic exposure modeling. Methods: Here, we appoint CoU for powder pouring during the industrial manufacturing of a paint batch by quantifying OC exposure levels and exposure determinants. The quantification was performed by using stationary measurements and a probabilistic Near-Field/Far-Field (NF/FF) exposure model. Work shift and OC concentration levels were quantified for pouring TiO 2 from big bags and small bags, pouring Micro Mica from small bags, and cleaning. The impact of exposure determinants on NF concentration level was quantified by (1) assessing exposure determinants correlation with the NF exposure level and (2) by performing simulations with different OCs. Results: Emission rate, air mixing between NF and FF and local ventilation were the most relevant exposure determinants affecting NF concentrations. Potentially risky OCs were identified by performing Reasonable Worst Case (RWC) simulations and by comparing the exposure 95 th percentile distribution with 10% of the occupational exposure limit value (OELV). The CS was shown safe except in RWC scenario (ventilation rate from 0.4 to 1.6 1/h, 100 m 3 room, no local ventilation, and NF ventilation of 1.6 m 3/min). Conclusions: The CoU assessment was considered to comply with European Chemicals Agency (ECHA) legislation and EN 689 exposure assessment strategy for testing compliance with OEL values. One RWC scenario would require measurements since the exposure level was 12.5% of the OELV.Peer reviewe

    Evaluating the Theoretical Background of STOFFENMANAGER® and the Advanced REACH Tool

    Get PDF
    STOFFENMANAGER® and the Advanced REACH Tool (ART) are recommended tools by the European Chemical Agency for regulatory chemical safety assessment. The models are widely used and accepted within the scientific community. STOFFENMANAGER® alone has more than 37 000 users globally and more than 310 000 risk assessment have been carried out by 2020. Regardless of their widespread use, this is the first study evaluating the theoretical backgrounds of each model. STOFFENMANAGER® and ART are based on a modified multiplicative model where an exposure base level (mg m−3) is replaced with a dimensionless intrinsic emission score and the exposure modifying factors are replaced with multipliers that are mainly based on subjective categories that are selected by using exposure taxonomy. The intrinsic emission is a unit of concentration to the substance emission potential that represents the concentration generated in a standardized task without local ventilation. Further information or scientific justification for this selection is not provided. The multipliers have mainly discrete values given in natural logarithm steps (…, 0.3, 1, 3, …) that are allocated by expert judgements. The multipliers scientific reasoning or link to physical quantities is not reported. The models calculate a subjective exposure score, which is then translated to an exposure level (mg m−3) by using a calibration factor. The calibration factor is assigned by comparing the measured personal exposure levels with the exposure score that is calculated for the respective exposure scenarios. A mixed effect regression model was used to calculate correlation factors for four exposure group [e.g. dusts, vapors, mists (low-volatiles), and solid object/abrasion] by using ~1000 measurements for STOFFENMANAGER® and 3000 measurements for ART. The measurement data for calibration are collected from different exposure groups. For example, for dusts the calibration data were pooled from exposure measurements sampled from pharmacies, bakeries, construction industry, and so on, which violates the empirical model basic principles. The calibration databases are not publicly available and thus their quality or subjective selections cannot be evaluated. STOFFENMANAGER® and ART can be classified as subjective categorization tools providing qualitative values as their outputs. By definition, STOFFENMANAGER® and ART cannot be classified as mechanistic models or empirical models. This modeling algorithm does not reflect the physical concept originally presented for the STOFFENMANAGER® and ART. A literature review showed that the models have been validated only at the ‘operational analysis’ level that describes the model usability. This review revealed that the accuracy of STOFFENMANAGER® is in the range of 100 000 and for ART 100. Calibration and validation studies have shown that typical log-transformed predicted exposure concentration and measured exposure levels often exhibit weak Pearson’s correlations (r is <0.6) for both STOFFENMANAGER® and ART. Based on these limitations and performance departure from regulatory criteria for risk assessment models, it is recommended that STOFFENMANAGER® and ART regulatory acceptance for chemical safety decision making should be explicitly qualified as to their current deficiencies.Peer reviewe

    Theoretical Background of Occupational-Exposure Models-Report of an Expert Workshop of the ISES Europe Working Group "Exposure Models"

    Get PDF
    On 20 October 2020, the Working Group "Exposure Models" of the Europe Regional Chapter of the International Society of Exposure Science (ISES Europe) organised an online workshop to discuss the theoretical background of models for the assessment of occupational exposure to chemicals. In this report, participants of the workshop with an active role before and during the workshop summarise the most relevant discussion points and conclusions of this well-attended workshop. ISES Europe has identified exposure modelling as one priority area for the strategic development of exposure science in Europe in the coming years. This specific workshop aimed to discuss the main challenges in developing, validating, and using occupational-exposure models for regulatory purposes. The theoretical background, application domain, and limitations of different modelling approaches were presented and discussed, focusing on empirical "modifying-factor" or "mass-balance-based" approaches. During the discussions, these approaches were compared and analysed. Possibilities to address the discussed challenges could be a validation study involving alternative modelling approaches. The wider discussion touched upon the close relationship between modelling and monitoring and the need for better linkage of the methods and the need for common monitoring databases that include data on model parameters.Peer reviewe

    Integrating Human Indoor Air Pollutant Exposure within Life Cycle Impact Assessment

    Get PDF
    Neglecting health effects from indoor pollutant emissions and exposure, as currently done in Life Cycle Assessment (LCA), may result in product or process optimizations at the expense of workers’ or consumers’ health. To close this gap, methods for considering indoor exposure to chemicals are needed to complement the methods for outdoor human exposure assessment already in use. This paper summarizes the work of an international expert group on the integration of human indoor and outdoor exposure in LCA, within the UNEP/SETAC Life Cycle Initiative. A new methodological framework is proposed for a general procedure to include human-health effects from indoor exposure in LCA. Exposure models from occupational hygiene and household indoor air quality studies and practices are critically reviewed and recommendations are provided on the appropriateness of various model alternatives in the context of LCA. A single-compartment box model is recommended for use as a default in LCA, enabling one to screen occupational and household exposures consistent with the existing models to assess outdoor emission in a multimedia environment. An initial set of model parameter values was collected. The comparison between indoor and outdoor human exposure per unit of emission shows that for many pollutants, intake per unit of indoor emission may be several orders of magnitude higher than for outdoor emissions. It is concluded that indoor exposure should be routinely addressed within LCA

    Differences in inflammation and acute phase response but similar genotoxicity in mice following pulmonary exposure to graphene oxide and reduced graphene oxide

    Get PDF
    We investigated toxicity of 2-3 layered >1 μm sized graphene oxide (GO) and reduced graphene oxide (rGO) in mice following single intratracheal exposure with respect to pulmonary inflammation, acute phase response (biomarker for risk of cardiovascular disease) and genotoxicity. In addition, we assessed exposure levels of particulate matter emitted during production of graphene in a clean room and in a normal industrial environment using chemical vapour deposition. Toxicity was evaluated at day 1, 3, 28 and 90 days (18, 54 and 162 μg/mouse), except for GO exposed mice at day 28 and 90 where only the lowest dose was evaluated. GO induced a strong acute inflammatory response together with a pulmonary (Serum-Amyloid A, Saa3) and hepatic (Saa1) acute phase response. rGO induced less acute, but a constant and prolonged inflammation up to day 90. Lung histopathology showed particle agglomerates at day 90 without signs of fibrosis. In addition, DNA damage in BAL cells was observed across time points and doses for both GO and rGO. In conclusion, pulmonary exposure to GO and rGO induced inflammation, acute phase response and genotoxicity but no fibrosis

    Moslem fundamentalist movements and their impact on Middle Eastern politics.

    Get PDF
    Most observers of the Arab world point out that Islam has and is currently playing a significant role in the region's political life. In particular, the more fanatical, religiously based political movements have and are determining the internal stability of the Middle East and consequently affect the United States' political and economic position in the world. The success of the Iranian Islamic Revolution has dramatically underscored the United States' ignorance of the political impact of Islam. Not only has the revolution embarrassed the United States but it has also threatened the stability of those regimes which America currently depends upon economically and politically; specifically, Saudi Arabia and Egypt. Given the political influence of Islam and the importance of Saudi Arabia to the United States, the question must be asked concerning Saudi Arabia's ability to withstand the current wave of Islamic revolutionary activity. Through an analysis of two previous politically influential Islamic Fundamentalist Movements in the Middle East; the Moslem Brotherhood of Egypt and the Iranian Islamic Revolutionary Movement, as well as an in depth analysis of Saudi Arabian society and politics, this thesis will prove that Saudi Arabia cannot withstand the strains presented by Islamic fundamentalist activity. Specifically, it will confirm that certain, identifable socio-political phenomena exist in Saudi Arabia today that were common to both Egypt and Iran and ultimately will lead to a change in relations between the United States and Saudi Arabia, if not a dramatic upheaval in Saudi Arabian society and internal politics.http://archive.org/details/moslemfundamenta00jayjLieutenant, United States NavyApproved for public release; distribution is unlimited

    Advanced data inversion applied to cascade impactor data

    No full text
    Currently, there is a lack of an FDA approved bio-equivalence test for generic aerosol drug products. The prime candidate for such a test is a device known as the cascade impactor. The cascade impactor uses a momentum-based impaction mechanism to classify incoming aerosols into different size bins. As the deposition of an aerosol in the lung is also driven by a momentum-based impaction, in principle, the cascade impactor is expected to be ideally suited for the task. In practice the cascade impactor has been limited by a major shortcoming: it does not sharply divide incoming aerosol into various size bins. To make impactors as accurate as possible, the current development methodology uses data from computational fluid dynamics (CFD) models to produce stages with maximally sharp cut-off sizes. However, these models do not account for the propensity for solid particles to rebound off the collection plate. As a result, cascade impactors have fairly straight impaction curves, but these curves come at the cost of increased variability. It is hypothesized that a superior impactor could be created by eliminating particle bounce, and then developing methods to accurately recover the data for the non-ideal impactor stage performance. In this work, tools are developed to help make such a device a reality. First, two inference-based inversion techniques, maximum entropy and fisher information, are formulated for use with the cascade impactor and tested with a model Andersen Cascade Impactor. Both techniques are shown to be capable of recovering accurate distributions from non-ideal impactors. The maximum entropy technique is found to be mathematically less complex, but also less accurate. The fisher information technique demonstrated superior accuracy, but it is much more mathematically complex and difficult to implement. For both inversion techniques, the relationship between neighboring impactor stages is found to be important to the accuracy of the inversion technique. In the second part, the ability of CFD tools to predict the impactor curve shape was tested. It was found that this approach lead to an over prediction of the sharpness of the impactor curves.Ph.D.Includes bibliographical referencesIncludes vitaby Eric Jayjoc
    corecore