670 research outputs found

    The maintenance of standing genetic variation: Gene flow vs. selective neutrality in Atlantic stickleback fish

    Get PDF
    Adaptation to derived habitats often occurs from standing genetic variation. The maintenance within ancestral populations of genetic variants favourable in derived habitats is commonly ascribed to long-term antagonism between purifying selection and gene flow resulting from hybridization across habitats. A largely unexplored alternative idea based on quantitative genetic models of polygenic adaptation is that variants favoured in derived habitats are neutral in ancestral populations when their frequency is relatively low. To explore the latter, we first identify genetic variants important to the adaptation of threespine stickleback fish (Gasterosteus aculeatus) to a rare derived habitat-nutrient-depleted acidic lakes-based on whole-genome sequence data. Sequencing marine stickleback from six locations across the Atlantic Ocean then allows us to infer that the frequency of these derived variants in the ancestral habitat is unrelated to the likely opportunity for gene flow of these variants from acidic-adapted populations. This result is consistent with the selective neutrality of derived variants within the ancestor. Our study thus supports an underappreciated explanation for the maintenance of standing genetic variation, and calls for a better understanding of the fitness consequences of adaptive variation across habitats and genomic backgrounds

    Study of a high spatial resolution 10B-based thermal neutron detector for application in neutron reflectometry: the Multi-Blade prototype

    Full text link
    Although for large area detectors it is crucial to find an alternative to detect thermal neutrons because of the 3He shortage, this is not the case for small area detectors. Neutron scattering science is still growing its instruments' power and the neutron flux a detector must tolerate is increasing. For small area detectors the main effort is to expand the detectors' performances. At Institut Laue-Langevin (ILL) we developed the Multi-Blade detector which wants to increase the spatial resolution of 3He-based detectors for high flux applications. We developed a high spatial resolution prototype suitable for neutron reflectometry instruments. It exploits solid 10B-films employed in a proportional gas chamber. Two prototypes have been constructed at ILL and the results obtained on our monochromatic test beam line are presented here

    Die höchsten Energien im Universum

    Get PDF

    Some Restrictions Abroad Affecting Corporations

    Get PDF
    A neutron detector concept based on solid layers of boron carbide enriched in 1 B has been in development for the last few years as an alternative for He-3 by collaboration between the ILL, ESS and Linkoping University. This Multi-Grid detector uses layers of aluminum substrates coated with (B4C)-B-10 on both sides that are traversed by the incoming neutrons. Detection is achieved using a gas counter readout principle. By segmenting the substrate and using multiple anode wires, the detector is made inherently position sensitive. This development is aimed primarily at neutron scattering instruments with large detector areas, such as time-of-flight chopper spectrometers. The most recent prototype has been built to be interchangeable with the He-3 detectors of IN6 at ILL. The 1 B detector has an active area of 32 x 48 cm(2). It was installed at the IN6 instrument and operated for several weeks, collecting data in parallel with the regularly scheduled experiments, thus providing the first side-by-side comparison with the conventional He-3 detectors. Results include an efficiency comparison, assessment of the in-detector scattering contribution, sensitivity to gamma-rays and the signal-to-noise ratio in time-of-flight spectra. The good expected performance has been confirmed with the exception of an unexpected background count rate. This has been identified as natural alpha activity in aluminum. New convertor substrates are under study to eliminate this source of background

    A comparison of transgenic rodent mutation and in vivo comet assay responses for 91 chemicals.

    Get PDF
    A database of 91 chemicals with published data from both transgenic rodent mutation (TGR) and rodent comet assays has been compiled. The objective was to compare the sensitivity of the two assays for detecting genotoxicity. Critical aspects of study design and results were tabulated for each dataset. There were fewer datasets from rats than mice, particularly for the TGR assay, and therefore, results from both species were combined for further analysis. TGR and comet responses were compared in liver and bone marrow (the most commonly studied tissues), and in stomach and colon evaluated either separately or in combination with other GI tract segments. Overall positive, negative, or equivocal test results were assessed for each chemical across the tissues examined in the TGR and comet assays using two approaches: 1) overall calls based on weight of evidence (WoE) and expert judgement, and 2) curation of the data based on a priori acceptability criteria prior to deriving final tissue specific calls. Since the database contains a high prevalence of positive results, overall agreement between the assays was determined using statistics adjusted for prevalence (using AC1 and PABAK). These coefficients showed fair or moderate to good agreement for liver and the GI tract (predominantly stomach and colon data) using WoE, reduced agreement for stomach and colon evaluated separately using data curation, and poor or no agreement for bone marrow using both the WoE and data curation approaches. Confidence in these results is higher for liver than for the other tissues, for which there were less data. Our analysis finds that comet and TGR generally identify the same compounds (mainly potent mutagens) as genotoxic in liver, stomach and colon, but not in bone marrow. However, the current database content precluded drawing assay concordance conclusions for weak mutagens and non-DNA reactive chemicals

    Determination of absolute neutrino masses from Z-bursts

    Get PDF
    Ultrahigh energy neutrinos (UHE\nu) scatter on relic neutrinos (R\nu) producing Z bosons, which can decay hadronically producing protons (Z-burst). We compare the predicted proton spectrum with the observed ultrahigh energy cosmic ray (UHECR) spectrum and determine the mass of the heaviest R\nu via a maximum likelihood analysis. Our prediction depends on the origin of the power-like part of the UHECR spectrum: m_\nu=2.75^{+1.28}_{-0.97} eV for Galactic halo and 0.26^{+0.20}_{-0.14} eV for extragalactic (EG) origin. The necessary UHE\nu flux should be detected in the near future.Comment: slight rewording, revised neutrino fluxes, conclusions unchanged, version to appear in Phys. Rev. Let

    Cardiac xenotransplantation: Recent preclinical progress with 3-month median survival

    Get PDF
    ObjectivesTransplantation is limited by a lack of human organ donors. Organs derived from animals, most likely the pig, represent a potential solution to this problem. For the heart, 90-day median graft survival of life-supporting pig hearts transplanted to nonhuman primates has been considered a reasonable standard for entry into the clinical arena. Overcoming the immune barrier to successful cardiac xenotransplantation is most appropriately first explored with the non–life-supporting heterotopic model.MethodsWe performed a series of 7 heterotopic heart transplantations from CD46 transgenic pigs to baboons using a combination of therapeutic agents largely targeted at controlling the synthesis of anti-pig antibodies. Rituximab (anti-CD20) and Thymoglobulin (rabbit antithymocyte globulin [ATG]; SangStat Medical Corp, Fremont, Calif) were used as induction therapy. Baseline immunosuppression consisted of splenectomy, tacrolimus, sirolimus, steroids, and TPC (an anti-Gal antibody therapeutic). Rejection events were not treated.ResultsBy using Kaplan-Meier analysis, median graft survival was 96 days (range, 15–137 days; 95% confidence interval, 38–99 days). Only 2 grafts were lost as a result of rejection, as defined by cessation of graft palpation. There was no evidence of a consumptive coagulopathy, infectious complications were treatable, and no posttransplantation lymphoproliferative disorders occurred. No cellular infiltration was observed.ConclusionsThis study reports the longest median survival to date (96 days) of pig hearts transplanted heterotopically into baboons. Duplication of these results in the orthotopic life-supporting position could bring cardiac xenotransplantation to the threshold of clinical application
    • …
    corecore