    The structural and parametrical organization of elements of a power supply system in the conditions of network centrism

    Get PDF
    Purpose. Development of indicators of the structural and parametrical organization of effective active and adaptive system of service of power supply systems in the conditions of ideology of Smart Grid. Methodology. In the conditions of application of ideology of Smart Grid for increase of intellectualization of electrical power system there is a need of introduction of the principle of a network centrism in the structural and parametrical organization of elements of power supply systems that involves performance of conditions on implementation of provisions of the principle of Situational Awareness. The essence of this principle consists in that, information on a condition of system has to be presented in the form convenient for the analysis, recognition, transfer, distribution and storage, to be coordinated for flexible and optimum development at the subsystem and object-by-object levels. Results. Structural and parametrical optimization of elements of power supply systems in the conditions of a network centrism and the concept of SG involves use of provisions of the theory of systems and concepts of multicriteria optimizing synthesis. It is offered to use the modified adaptive indicator of the generalizing effect of synthesis of structure of active and adaptive system of service of power supply systems in the form of a difference of the generalizing effects: the introduced option of structure of system and basic. Originality. Introduction of an adaptive indicator of synthesis of system of service of power supply systems considers the concept of «service of system on the basis of a response» in the presence of false and true refusals. Practical value. Use of the specified indicator will allow to specify procedure of selection of competitive options for the purpose of definition of a set of admissible structures which meet the requirements of criterion function.В статье рассмотрены тенденции развития и принципы организации интеллектуальных энергосистем при введении понятия сетецентризма в условиях идеологии Smart Grid. В качестве решения задач указанной проблематики предлагается создание активно-адаптивной системы, реализующей концепцию «обслуживания системы на основе отклика»

    Numerical computation of electric fields in presence of curvilinear interface between conductive and non-conductive media

    Get PDF
    Purpose. To elaborate a method of electric field numerical calculation in systems with curved boundaries between conductive and non-conductive media at final volume method usage and application of the rectangular grids. Methodology. At electric field calculation in quasi-stationary approximation, potential of the whole conductive object (rod) is constant. At final difference scheme writing, presence of the curved part of the boundary between conducting and non-conducting media has been taking into account as follows. It was supposed that curved section complements the closed loop on which integration of the solvable equation is done instead of a straight section which extends within a conducting medium. Usage of this approach allows taking into account square of the curved sections of the boundary and distance between surface of non conductive medium and nearest nodes of the computational grid. Results. Dependence of the maximum electric field intensity on the height and radius of curvature peaks rods has been got with the help of calculations. As a result, a polynomial approximation for the analytical expression of the external electric field intensity, upon which application to the conductive object of a certain height and radius of curvature of its top, corona discharges will develop.Описаны принципы учета криволинейных границ раздела при использовании метода конечных объемов для расчета усиления электрического поля на вершинах проводящих стержней. С помощью проведенных расчетов получена зависимость максимальной напряженности электрического поля от высоты и радиуса скругления вершин стержней. В результате аппроксимации данной зависимости полиномом записано аналитическое выражение для напряженности внешнего электрического поля, при приложении которого к проводящему объекту определенной высоты и радиуса скругления вершины на нем развивается коронный разряд

    Einstein gravity as a 3D conformally invariant theory

    Get PDF
    We give an alternative description of the physical content of general relativity that does not require a Lorentz invariant spacetime. Instead, we find that gravity admits a dual description in terms of a theory where local size is irrelevant. The dual theory is invariant under foliation preserving 3-diffeomorphisms and 3D conformal transformations that preserve the 3-volume (for the spatially compact case). Locally, this symmetry is identical to that of Horava-Lifshitz gravity in the high energy limit but our theory is equivalent to Einstein gravity. Specifically, we find that the solutions of general relativity, in a gauge where the spatial hypersurfaces have constant mean extrinsic curvature, can be mapped to solutions of a particular gauge fixing of the dual theory. Moreover, this duality is not accidental. We provide a general geometric picture for our procedure that allows us to trade foliation invariance for conformal invariance. The dual theory provides a new proposal for the theory space of quantum gravity.Comment: 27 pages. Published version (minor changes and corrections

    СЕТЕЦЕНТРИЧЕСКАЯ ОПТИМИЗАЦИЯ ОПЕРАТИВНОГО ОБСЛУЖИВАНИЯ ЭЛЕМЕНТОВ ЭНЕРГОСИСТЕМЫ

    Get PDF
    Purpose. Development of precision selection criteria of options of technical realization of effective active and adaptive system of expeditious service of elements of a power supply system in the conditions of network-centric management. Methodology. In development of power supply systems their evolution from the elementary forms using elementary network technologies and models of interactions in power to more irregular shapes within the concept of Smart Grid with elements of network-centric character is observed. This direction is based on Internet-technologies of the last generation, and realize models of power activity which couldn't be realized before. Results. The number of possible options of active and adaptive system of expeditious service of elements of a power supply system is usually rather big and it is difficult to choose the acceptable option by direct search. Elimination of admissible options of the technical realization constructed on the principles of a network centrism means application of the theory of multicriteria optimization from a position of discrete programming. The basis of procedure of elimination is made by algorithm of an assessment of system by criterion of accuracy. Originality. The case of an assessment of the precision characteristic of system at restrictions for the set accuracy is connected with need of decomposition of requirements of all system in general and on separate subsystems. For such decomposition the ratios connecting the accuracy of functioning of a separate subsystem with variations of parameters of all system, and also with precision characteristics of subsystems of the lower levels influencing this subsystem are received. Practical value. In the conditions of the network-centric organization of management of expeditious service of elements of a power supply system elimination of options of subsystems when using precision criterion allows to receive the maximum number of essentially possible options of system of service taking into account the accepted service strategy.В статье уделено внимание вопросам использования сетецентрического подхода при формировании активно-адаптивной системы оперативного обслуживания элементов энергосистемы в условиях идеологии Smart Grid. Определен точностной критерий отсева вариантов технической реализации этой системы, реализующей концепцию «обслуживания на основе отклика».У статті приділена увага питанням використання сетецентричного підходу при формуванні активно-адаптивної системи оперативного обслуговування елементів енергосистеми в умовах ідеології Smart Grid. Визначений точносний критерій відсіювання варіантів технічної реалізації цієї системи, що реалізує концепцію «обслуговування на основі відклику»

    СЕТЕЦЕНТРИЧЕСКИЕ ТЕХНОЛОГИИ УПРАВЛЕНИЯ РЕЖИМАМИ РАБОТЫ ТРЕХФАЗНОЙ СЕТИ

    Get PDF
    Purpose. The development of the control system for three-phase network is based on intelligent technologies of network-centric control of heterogeneous objects. The introduction of unmanned aerial vehicles for monitoring of three-phase network increases the efficiency of management. Methodology. The case of decomposition of the instantaneous capacities of the fixed and variable components for 3-wire system. The features of power balance for the different modes of its functioning. It should be noted that symmetric sinusoidal mode is balanced and good, but really unbalanced, if the standard reactive power is not zero. To solve the problem of compensation is sufficient knowledge of the total value of the inactive components of full power (value of the inactive power) without detail. The creation of a methodology of measurement and assessment will require knowledge of the magnitudes of each inactive component separately, which leads to the development of a unified approach to the measurement and compensation of inactive components of full power and the development of a generalized theory of power. Results. Procedure for the compensation of the current of zero sequence excludes from circuit the source, as the active component of instantaneous power of zero sequence, and a vector due to a current of zero sequence. This procedure is performed without time delay as it does not require integration. Only a 3–wire system with symmetrical voltage eliminates pulsations and symmetrization of the equivalent conductances of the phases of the task. Under asymmetric voltage, the power is different, its analysis requires the creation of a vector mathematical model of the energy processes of asymmetrical modes of 3–phase systems. Originality. The proposed method extends the basis of the vector method for any zero sequence voltages and shows that the various theories of instantaneous power three wired scheme due to the choice of a basis in a two-dimensional subspace. Practical value. The algorithm and software implementation for the decomposition of the zero sequence current, which allocated the procedure of obtaining null-balanced vectors of phase and interfacial voltage, calculation of active and inactive instantaneous power is zero balanced mode. The simulation results obtained in the software package Matlab by the method of visual programming in Simulink.Интеграция интеллектуальных и сетецентрических технологий в процесс управления режимами работы трехфазной сети обеспечивают оперативность компенсации нелинейностей в системе за счет ортогонального разложения тока и использования метода базисных функций для минимизации потерь

    The development of the theory of instantaneous power of three-phase network in terms of network centrism

    Get PDF
    Purpose. Information technologies allow multidimensional analysis of information about the state of the power system in a single information space in terms of providing network-centric approach to control and use of unmanned aerial vehicles as tools for condition monitoring of three-phase network. Methodology. The idea of energy processes in three independent (rather than four dependent) curves vector-functions with values in the arithmetic three-dimensional space adequately for both 4-wire and 3–wire circuits. The presence of zero sequence current structural (and mathematically) features a 4-wire scheme of energy from a 3-wire circuit. The zero sequence voltage caused by the displacement of the zero voltage phases. Offset zero in the calculations can be taken into account by appropriate selection of the reference voltages. Both of these energetic phenomena with common methodical positions are described in the framework of the general mathematical model, in which a significant role is played by the ort zero sequence. Results. Vector approach with a unified voice allows us to obtain and analyze new energy characteristics for 4–wire and 3–wire circuits in sinusoidal and non-sinusoidal mode, both in temporal and frequency domain. Originality. Symmetric sinusoidal mode is balanced, even with non-zero reactive power. The converse is not true. The mode can be balanced and unbalanced load. The mode can be balanced and unbalanced voltage. Practical value. Assessing balance in network mode and the impact of instantaneous power on the magnitude of the losses, will allow to avoid the appearance of zero sequence and, thus, to improve the quality of electricity.Обеспечение сетецентрического подхода к режиму управления трехфазной сетью и оценка сбалансированности режима сети с учетом влияния мгновенной мощности на величину потерь даст возможность исключить появление нулевой последовательности и, тем самым, повысить качество электроэнергии

    Network-centric technologies for control of three-phase network operation modes

    Get PDF
    Purpose. The development of the control system for three-phase network is based on intelligent technologies of network-centric control of heterogeneous objects. The introduction of unmanned aerial vehicles for monitoring of three-phase network increases the efficiency of management. Methodology. The case of decomposition of the instantaneous capacities of the fixed and variable components for 3-wire system. The features of power balance for the different modes of its functioning. It should be noted that symmetric sinusoidal mode is balanced and good, but really unbalanced, if the standard reactive power is not zero. To solve the problem of compensation is sufficient knowledge of the total value of the inactive components of full power (value of the inactive power) without detail. The creation of a methodology of measurement and assessment will require knowledge of the magnitudes of each inactive component separately, which leads to the development of a unified approach to the measurement and compensation of inactive components of full power and the development of a generalized theory of power. Results. Procedure for the compensation of the current of zero sequence excludes from circuit the source, as the active component of instantaneous power of zero sequence, and a vector due to a current of zero sequence. This procedure is performed without time delay as it does not require integration. Only a 3–wire system with symmetrical voltage eliminates pulsations and symmetrization of the equivalent conductances of the phases of the task. Under asymmetric voltage, the power is different, its analysis requires the creation of a vector mathematical model of the energy processes of asymmetrical modes of 3–phase systems. Originality. The proposed method extends the basis of the vector method for any zero sequence voltages and shows that the various theories of instantaneous power three wired scheme due to the choice of a basis in a two-dimensional subspace. Practical value. The algorithm and software implementation for the decomposition of the zero sequence current, which allocated the procedure of obtaining null-balanced vectors of phase and interfacial voltage, calculation of active and inactive instantaneous power is zero balanced mode. The simulation results obtained in the software package Matlab by the method of visual programming in Simulink.Интеграция интеллектуальных и сетецентрических технологий в процесс управления режимами работы трехфазной сети обеспечивают оперативность компенсации нелинейностей в системе за счет ортогонального разложения тока и использования метода базисных функций для минимизации потерь

    ЦИФРОВА ПІДСТАНЦІЯ СКЛАДОВА СИСТЕМИ "SMART GRID"

    Get PDF
    New production technologies of modern control systems have moved from the stage of research and experimentation into the stage of practical use. Modern communication standards for the exchange of information are developed and introduced. Digital devices, protectors and automation are widely used. There has been substantial development of hardware and software of control systems.Новые технологии производства современных систем управления перешли из стадии научных исследований и экспериментов в стадию практического использования. Разработаны и внедряются современные коммуникационные стандарты обмена информацией. Широко применяются цифровые устройства защиты и автоматики. Произошло существенное развитие аппаратных и программных средств систем управления.Нові технології виробництва сучасних систем управління перейшли зі стадії наукових досліджень і експериментів у стадію практичного використання. Розроблені та впроваджуються сучасні комунікаційні стандарти обміну інформацією. Широко застосовуються цифрові пристрої захисту та автоматики. Відбувся істотний розвиток апаратних і програмних засобів систем управління

    Quantum Cosmological Relational Model of Shape and Scale in 1-d

    Full text link
    Relational particle models are useful toy models for quantum cosmology and the problem of time in quantum general relativity. This paper shows how to extend existing work on concrete examples of relational particle models in 1-d to include a notion of scale. This is useful as regards forming a tight analogy with quantum cosmology and the emergent semiclassical time and hidden time approaches to the problem of time. This paper shows furthermore that the correspondence between relational particle models and classical and quantum cosmology can be strengthened using judicious choices of the mechanical potential. This gives relational particle mechanics models with analogues of spatial curvature, cosmological constant, dust and radiation terms. A number of these models are then tractable at the quantum level. These models can be used to study important issues 1) in canonical quantum gravity: the problem of time, the semiclassical approach to it and timeless approaches to it (such as the naive Schrodinger interpretation and records theory). 2) In quantum cosmology, such as in the investigation of uniform states, robustness, and the qualitative understanding of the origin of structure formation.Comment: References and some more motivation adde

    Extended Thromboprophylaxis with Betrixaban in Acutely Ill Medical Patients

    Get PDF
    Background Patients with acute medical illnesses are at prolonged risk for venous thrombosis. However, the appropriate duration of thromboprophylaxis remains unknown. Methods Patients who were hospitalized for acute medical illnesses were randomly assigned to receive subcutaneous enoxaparin (at a dose of 40 mg once daily) for 10±4 days plus oral betrixaban placebo for 35 to 42 days or subcutaneous enoxaparin placebo for 10±4 days plus oral betrixaban (at a dose of 80 mg once daily) for 35 to 42 days. We performed sequential analyses in three prespecified, progressively inclusive cohorts: patients with an elevated d-dimer level (cohort 1), patients with an elevated d-dimer level or an age of at least 75 years (cohort 2), and all the enrolled patients (overall population cohort). The statistical analysis plan specified that if the between-group difference in any analysis in this sequence was not significant, the other analyses would be considered exploratory. The primary efficacy outcome was a composite of asymptomatic proximal deep-vein thrombosis and symptomatic venous thromboembolism. The principal safety outcome was major bleeding. Results A total of 7513 patients underwent randomization. In cohort 1, the primary efficacy outcome occurred in 6.9% of patients receiving betrixaban and 8.5% receiving enoxaparin (relative risk in the betrixaban group, 0.81; 95% confidence interval [CI], 0.65 to 1.00; P=0.054). The rates were 5.6% and 7.1%, respectively (relative risk, 0.80; 95% CI, 0.66 to 0.98; P=0.03) in cohort 2 and 5.3% and 7.0% (relative risk, 0.76; 95% CI, 0.63 to 0.92; P=0.006) in the overall population. (The last two analyses were considered to be exploratory owing to the result in cohort 1.) In the overall population, major bleeding occurred in 0.7% of the betrixaban group and 0.6% of the enoxaparin group (relative risk, 1.19; 95% CI, 0.67 to 2.12; P=0.55). Conclusions Among acutely ill medical patients with an elevated d-dimer level, there was no significant difference between extended-duration betrixaban and a standard regimen of enoxaparin in the prespecified primary efficacy outcome. However, prespecified exploratory analyses provided evidence suggesting a benefit for betrixaban in the two larger cohorts. (Funded by Portola Pharmaceuticals; APEX ClinicalTrials.gov number, NCT01583218. opens in new tab.
    corecore