8,620 research outputs found

    Biosimilar Pegfilgrastim: Improving Access and Optimising Practice to Supportive Care that Enables Cure

    Get PDF
    Febrile neutropenia (FN) is a serious complication of chemotherapy, which can cause significant morbidity and mortality, result in dose delays and reductions and, ultimately, reduce cancer survival. Over the past decade, the availability of biosimilar filgrastim (short-acting granulocyte colony-stimulating factor [G-CSF]) has transformed patient access, with clear evidence of clinical benefit at preventing FN at reduced costs. In 2019, seven biosimilar pegfilgrastims (long-acting G-CSFs) were licensed, creating optimal market conditions and choice for prescribers. FN affects up to 117 per 1000 cancer patients, with mortality rates in the range of 2–21%. By reducing FN incidence and improving chemotherapy relative dose intensity (RDI), G-CSF has been associated with a 3.2% absolute survival benefit. Guidelines recommend primary prophylaxis and that filgrastim be administered for 10–14 days, while pegfilgrastim is administered once per cycle. When taken according to the guidelines, pegfilgrastim and filgrastim are equally effective. However, in routine clinical practice, filgrastim is often under-dosed (< 7 days) and has been shown to be inferior to pegfilgrastim at reducing FN incidence, hospitalisations and maintaining RDI. Once-per-cycle administration with pegfilgrastim might also aid patient adherence. The introduction of biosimilar pegfilgrastim should instigate a rethink of neutropenia management. Biosimilar pegfilgrastim

    Application of large area SiPMs for the readout of a plastic scintillator based timing detector

    Full text link
    In this study an array of eight 6 mm x 6 mm area SiPMs was coupled to the end of a long plastic scintillator counter which was exposed to a 2.5 GeV/c muon beam at the CERN PS. Timing characteristics of bars with dimensions 150 cm x 6 cm x 1 cm and 120 cm x 11 cm x 2.5 cm have been studied. An 8-channel SiPM anode readout ASIC (MUSIC R1) based on a novel low input impedance current conveyor has been used to read out and amplify SiPMs independently and sum the signals at the end. Prospects for applications in large-scale particle physics detectors with timing resolution below 100 ps are provided in light of the results

    Application of large area SiPMs for the readout of a plastic scintillator based timing detector

    Full text link
    In this study an array of eight 6 mm x 6 mm area SiPMs was coupled to the end of a long plastic scintillator counter which was exposed to a 2.5 GeV/c muon beam at the CERN PS. Timing characteristics of bars with dimensions 150 cm x 6 cm x 1 cm and 120 cm x 11 cm x 2.5 cm have been studied. An 8-channel SiPM anode readout ASIC (MUSIC R1) based on a novel low input impedance current conveyor has been used to read out and amplify SiPMs independently and sum the signals at the end. Prospects for applications in large-scale particle physics detectors with timing resolution below 100 ps are provided in light of the results

    A Note on the Temporary Misregistration of Landsat-8 Operational Land Imager (OLI) and Sentinel-2 Multi Spectral Instrument (MSI) Imagery

    Get PDF
    The Landsat-8 and Sentinel-2 sensors provide multi-spectral image data with similar spectral and spatial characteristics that together provide improved temporal coverage globally. Both systems are designed to register Level 1 products to a reference image framework, however, the Landsat-8 framework, based upon the Global Land Survey images, contains residual geolocation errors leading to an expected sensor-to-sensor misregistration of 38 m (2σ). These misalignments vary geographically but should be stable for a given area. The Landsat framework will be readjusted for consistency with the Sentinel-2 Global Reference Image, with completion expected in 2018. In the interim, users can measure Landsat-to-Sentinel tie points to quantify the misalignment in their area of interest and if appropriate to reproject the data to better alignment

    Areas of work-life in Spanish hostelry professionals: explanatory power on burnout dimensions

    Get PDF
    BackgroundResearchers have studied for decades workplace stress and burnout to identify their relationship to health and wellness. This research has focused on stress levels in people, as well as on environmental and personal factors that contribute to experiencing stress or burnout. In addition to the burnout measurement questionnaires (MBI-GS), Leiter and Maslach designed a model to evaluate the areas of work environment that relate to this construct (Areas of Worklife Scale-AWLS).The goal of the present research was to analyze the psychometric properties of a Spanish translation of the MBI (GS) and the AWLS with a Spanish-speaking population. This work makes a substantial contribution by addressing the need to use validated measures and methods when exploring the positive and negative aspects of organizations. These conditions provide a means to accurately evaluate the impact of interventions aimed to address stress and burnout.MethodCross-sectional study with self-report measures. The sample was comprised of 452 managers and employees (hotels, restaurants, catering) of Aragon (Spain). There were approximately equal numbers of women and men (45, 4% vs. 54, 6%). The average age of participants was 36.6years (SD=10.03). A battery of questionnaires was used: Socio-demographic and work characteristics, Scale of stress and health symptoms, Maslach Burnout Inventory-General Survey (MBI-GS), Areas of Worklife Scale (AWLS).ResultsThe results showed optimal psychometric properties in both questionnaires, especially in terms of the predictive capacity of the AWLS in each of the MBI-GS dimensions.ConclusionsThe best explained dimension is that of emotional exhaustion. The manageable load variable is the one that most contributes to predicting burnout levels. For future interventions, the results confirm the need to verify the levels of each area of work, in order to focus on the most deteriorated ones

    Synthesis and gas adsorption properties of mesoporous silica-NH2-MIL-53(Al) core-shell spheres

    Get PDF
    Ordered mesoporous silica-NH2-MIL-53(Al) core-shell spheres of about 4 ”m in diameter have been synthesized by seeding the corresponding mesoporous silica spheres (MSSs) with crystals of NH2-MIL-53(Al) and subsequent secondary crystal growth into a MOF shell. The morphology of the particles was analyzed by SEM, while TGA, EDX and XRD characterizations gave information on the composition and structure of this material and the activation of the MOF. N2 adsorption analysis revealed that the NH2-MIL-53(Al) shell controlled the access of guest molecules into the hydrophilic silica mesoporous structure, while the breathing behavior of the microporous NH2-MIL-53(Al) shell was confirmed by CO2 adsorption isotherms

    Cu-BTC Functional Microdevices as Smart Tools for Capture and Preconcentration of Nerve Agents

    Get PDF
    Cu-based metal-organic framework (MOF) microdevices are applied in sampling and preconcentration of nerve agents (NAs) diluted in gaseous streams. An in situ electrochemical-assisted synthesis of a Cu-benzene-1, 3, 5-tricarboxylate (BTC) thick film is carried out to functionalize a Cu-modified glass substrate. This simple, rapid, reproducible, and easy-to-integrate MOF synthesis approach enables the microfabrication of functional micro-preconcentrators with a large Brunauer-Emmett-Teller (BET) surface area (above 2000 cm2) and an active pore volume (above 90 nL) for the efficient adsorption of nerve agent molecules along the microfluidic channel 2.5 cm in length. The equilibrium adsorption capacity of the bulk material has been characterized through thermogravimetric analysis after exposure to controlled atmospheres of a sarin gas surrogate, dimethyl methylphosphonate (DMMP), in both dry and humid conditions (30% RH at 293 K). Breakthrough tests at the ppm level (162 mg/m3) reveal equilibrium adsorption capacities up to 691 mg/g. The preconcentration performance of such ”-devices when dealing with highly diluted surrogate atmosphere, i.e., 520 ppbV (2.6 mg/m3) at 298 K, leads to preconcentration coefficients up to 171 for sample volume up to 600 STP cm3. We demonstrate the potentialities of Cu-BTC micro-preconcentrators as smart first responder tools for "on-field" detection of nerve agents in the gas phase at relevant conditions

    Health benefits of physical activity related to an urban riverside regeneration

    Get PDF
    The promotion of physical activity through better urban design is one pathway by which health and well-being improvements can be achieved. This study aimed to quantify health and health-related economic impacts associated with physical activity in an urban riverside park regeneration project in Barcelona, Spain. We used data from Barcelona local authorities and meta-analysis assessing physical activity and health outcomes to develop and apply the “Blue Active Tool”. We estimated park user health impacts in terms of all-cause mortality, morbidity (ischemic heart disease; ischemic stroke; type 2 diabetes; cancers of the colon and breast; and dementia), disability-adjusted life years (DALYs) and health-related economic impacts. We estimated that 5753 adult users visited the riverside park daily and performed different types of physical activity (walking for leisure or to/from work, cycling, and running). Related to the physical activity conducted on the riverside park, we estimated an annual reduction of 7.3 deaths (95% CI: 5.4; 10.2), and 6.2 cases of diseases (95% CI: 2.0; 11.6). This corresponds to 11.9 DALYs (95% CI: 3.4; 20.5) and an annual health-economic impact of 23.4 million euros (95% CI: 17.2 million; 32.8 million). The urban regeneration intervention of this riverside park provides health and health-related economic benefits to the population using the infrastructure

    Background discrimination capabilities of a heat and ionization germanium cryogenic detector

    Get PDF
    The discrimination capabilities of a 70 g heat and ionization Ge bolometer are studied. This first prototype has been used by the EDELWEISS Dark Matter experiment, installed in the Laboratoire Souterrain de Modane, for direct detection of WIMPs. Gamma and neutron calibrations demonstrate that this type of detector is able to reject more than 99.6% of the background while retaining 95% of the signal, provided that the background events distribution is not biased towards the surface of the Ge crystal. However, the 1.17 kg.day of data taken in a relatively important radioactive environment show an extra population slightly overlapping the signal. This background is likely due to interactions of low energy photons or electrons near the surface of the crystal, and is somewhat reduced by applying a higher charge-collecting inverse bias voltage (-6 V instead of -2 V) to the Ge diode. Despite this contamination, more than 98% of the background can be rejected while retaining 50% of the signal. This yields a conservative upper limit of 0.7 event.day^{-1}.kg^{-1}.keV^{-1}_{recoil} at 90% confidence level in the 15-45 keV recoil energy interval; the present sensitivity appears to be limited by the fast ambient neutrons. Upgrades in progress on the installation are summarized.Comment: Submitted to Astroparticle Physics, 14 page
    • 

    corecore