14 research outputs found

    The OH (3-1) nightglow volume emission rate retrieved from OSIRIS measurements: 2001 to 2015

    Get PDF
    The OH airglow has been used to investigate the chemistry and dynamics of the mesosphere and the lower thermosphere (MLT) for a long time. The infrared imager (IRI) aboard the Odin satellite has been recording the night-time 1.53 mu m OH (3-1) emission for more than 15 years (2001-2015), and we have recently processed the complete data set. The newly derived data products contain the volume emission rate profiles and the Gaussian-approximated layer height, thickness, peak intensity and zenith intensity, and their corresponding error estimates. In this study, we describe the retrieval steps for these data products. We also provide data screening recommendations. The monthly zonal averages depict the well-known annual oscillation and semi-annual oscillation signatures, which demonstrate the fidelity of the data set (https://doi.org/10.5281/zenodo.4746506, Li et al., 2021). The uniqueness of this Odin IRI OH long-term data set makes it valuable for studying various topics, for instance, the sudden stratospheric warming events in the polar regions and solar cycle influences on the MLT

    Effect of volcanic aerosol on stratospheric NOâ‚‚ and Nâ‚‚Oâ‚… from 2002-2014 as measured by Odin-OSIRIS and Envisat-MIPAS

    Get PDF
    Following the large volcanic eruptions of Pinatubo in 1991 and El Chichón in 1982, decreases in stratospheric NO₂ associated with enhanced aerosol were observed. The Optical Spectrograph and Infrared Imaging Spectrometer (OSIRIS) measured the widespread enhancements of stratospheric aerosol following seven volcanic eruptions between 2002 and 2014, although the magnitudes of these eruptions were all much smaller than the Pinatubo and El Chichón eruptions. In order to isolate and quantify the relationship between volcanic aerosol and NO₂, NO₂ anomalies were calculated using measurements from OSIRIS and the Michelson Interferometer for Passive Atmospheric Sounding (MIPAS). In the tropics, variability due to the quasi-biennial oscillation was subtracted from the time series. OSIRIS profile measurements indicate that the strongest anticorrelations between NO₂ and volcanic aerosol extinction were for the 5 km layer starting  ∼  3 km above the climatological mean tropopause at the given latitude. OSIRIS stratospheric NO₂ partial columns in this layer were found to be smaller than background NO₂ levels during these aerosol enhancements by up to  ∼  60 % with typical Pearson correlation coefficients of R ∼ −0. 7. MIPAS also observed decreases in NO₂ partial columns during periods affected by volcanic aerosol, with percent differences of up to  ∼  25 % relative to background levels. An even stronger anticorrelation was observed between OSIRIS aerosol optical depth and MIPAS N₂O₅ partial columns, with R ∼ −0. 9, although no link with MIPAS HNO3 was observed. The variation in OSIRIS NO₂ with increasing aerosol was found to be consistent with simulations from a photochemical box model within the estimated model uncertainty

    Atmospheric volume emission tomography from a satellite platform

    No full text
    It is extremely important for current atmospheric modeling efforts that the two and three dimensional structure of the atmospheric constituents be known. It is equally important that these constituent profiles be known globally with high temporal resolution. Optical instruments onboard satellite platforms can provide measurements that make this knowledge possible. This work presents a tomographic technique to use line of sight brightness measurements of the atmosphere made by an orbiting optical instrument to determine the two dimensional volume emission profile that has been remotely sensed. The basic technique was originally developed to deblur Fabry-Perot images and is closely related to the processes used in medical imaging. Although the tomographic technique was originally developed as a statistical analysis it is shown that it is the viewing geometry that is the fundamental characteristic with respect to algorithm performance. Further, it is shown that the tomographic technique is capable of resolving structures in the atmospheric volume emission profile that are as small as 300 km along the satellite track with I km vertical resolution. It is found that this holds for a wide range of realistic operational conditions that include significant observational noise. The Swedish based Odin spacecraft scheduled for launch in early 2000, will fly in a sun-synchronous dusk-dawn orbit and will include the Canadian OSIRIS instrument. OSIRIS is able to measure the oxygen infrared atmospheric bond simultaneously at multiple tangent altitudes at two separate wavelengths. These measurements am related to the mesospheric ozone profile and are ideal inputs for the tomographic technique. It is shown that there is no degradation in the algorithm performance even though the oxygen infrared atmospheric bond emissions are absorbed

    Optical Design and Performance of the Odin UV/Visible Spectrograph and Infrared Imager Instrument

    Get PDF
    Sweden\u27s Odin international scientific small satellite is planned for launch into a sun synchronous low earth orbit in 1998. Odin\u27s mission will be both astronomy and atmospheric science (aeronomy). Its principle aeronomy payload is a high performance, lightweight (12 kilograms) ultraviolet/visible imaging spectrograph and infrared imager, that will point at the limb of the earth\u27s upper atmosphere and measure molecular species associated with ozone chemistry, detect aerosols and tomographically measure and map ozone. The Canadian Space Agency is funding this payload, which has the acronym OSIRIS , and Routes Inc. is currently building the flight model. OSIRIS is effectively two optical instruments mounted in a common optical housing and supported by common electronics. The first instrument consists of three infrared telescopes, each with an Indium Gallium Arsenide (InGaAs) linear detector. The second part is a high precision imaging spectrograph with a wavelength range of 280 to 800 nanometers, which uses a UV-enhanced CCD. The imaging spectrograph uses compact reflective optics and an aspheric reflective ruled grating, and provides excellent spectral imaging performance and stray-light rejection. This paper first briefly describes the overall instrument and then describes the optical design and the Development Model optical and sky test performance results. This paper includes a brief description of how OSIRIS will obtain valuable new environmental information on the upper atmosphere, and the requirements this places on the instruments optical design

    Model estimations of geophysical variability between satellite measurements of ozone profiles

    Get PDF
    In order to validate satellite measurements of atmospheric composition, it is necessary to understand the range of random and systematic uncertainties inherent in the measurements. On occasions where measurements from two different satellite instruments do not agree within those estimated uncertainties, a common explanation is that the difference can be assigned to geophysical variability, i.e., differences due to sampling the atmosphere at different times and locations. However, the expected geophysical variability is often left ambiguous and rarely quantified. This paper describes a case study where the geophysical variability of O3 between two satellite instruments – ACE-FTS (Atmospheric Chemistry Experiment – Fourier Transform Spectrometer) and OSIRIS (Optical Spectrograph and InfraRed Imaging System) – is estimated using simulations from climate models. This is done by sampling the models CMAM (Canadian Middle Atmosphere Model), EMAC (ECHAM/MESSy Atmospheric Chemistry), and WACCM (Whole Atmosphere Community Climate Model) throughout the upper troposphere and stratosphere at times and geolocations of coincident ACE-FTS and OSIRIS measurements. Ensemble mean values show that in the lower stratosphere, O3 geophysical variability tends to be independent of the chosen time coincidence criterion, up to within 12 h; and conversely, in the upper stratosphere geophysical variation tends to be independent of the chosen distance criterion, up to within 2000 km. It was also found that in the lower stratosphere, at altitudes where there is the greatest difference between air composition inside and outside the polar vortex, the geophysical variability in the southern polar region can be double of that in the northern polar region. This study shows that the ensemble mean estimates of geophysical variation can be used when comparing data from two satellite instruments to optimize the coincidence criteria, allowing for the use of more coincident profiles while providing an estimate of the geophysical variation within the comparison results

    Improved OSIRIS NO<sub>2</sub> retrieval algorithm: description and validation

    No full text
    International audienceA new retrieval algorithm for OSIRIS (Optical Spectrograph and Infrared Imager System) nitrogen dioxide (NO2) profiles is described and validated. The algorithm relies on spectral fitting to obtain slant column densities of NO2 , followed by inversion using an algebraic reconstruction technique and the SaskTran spherical radiative transfer model (RTM) to obtain vertical profiles of local number density. The validation covers different latitudes (tropical to polar), years (2002–2012), all seasons (winter, spring, summer , and autumn), different concentrations of nitrogen dioxide (from denoxified polar vortex to polar summer), a range of solar zenith angles (68.6–90.5 °), and altitudes between 10.5 and 39 km, thereby covering the full retrieval range of a typical OSIRIS NO2 profile. The use of a larger spectral fitting window than used in previous retrievals reduces retrieval uncertainties and the scatter in the retrieved profiles due to noisy radiances. Improvements are also demonstrated through the validation in terms of bias reduction at 15–17 km relative to the OSIRIS operational v3.0 algorithm. The diur-nal variation of NO2 along the line of sight is included in a fully spherical multiple scattering RTM for the first time. Using this forward model with built-in photochemistry, the scatter of the differences relative to the correlative balloon NO2 profile data is reduced

    Validation of Ozone Profile Retrievals Derived from the OMPS LP Version 2.5 Algorithm Against Correlative Satellite Measurements

    No full text
    The Limb Profiler (LP) is a part of the Ozone Mapping and Profiler Suite launched on board of the Suomi NPP satellite in October 2011. The LP measures solar radiation scattered from the atmospheric limb in ultraviolet and visible spectral ranges between the surface and 80 km. These measurements of scattered solar radiances allow for the retrieval of ozone profiles from cloud tops up to 55 km. The LP started operational observations in April 2012. In this study we evaluate more than 5.5 years of ozone profile measurements from the OMPS LP processed with the new NASA GSFC version 2.5 retrieval algorithm. We provide a brief description of the key changes that had been implemented in this new algorithm, including a pointing correction, new cloud height detection, explicit aerosol correction and a reduction of the number of wavelengths used in the retrievals. The OMPS LP ozone retrievals have been compared with independent satellite profile measurements obtained from the Aura Microwave Limb Sounder (MLS), Atmospheric Chemistry Experiment Fourier Transform Spectrometer (ACE-FTS) and Odin Optical Spectrograph and InfraRed Imaging System (OSIRIS). We document observed biases and seasonal differences and evaluate the stability of the version 2.5 ozone record over 5.5 years. Our analysis indicates that the mean differences between LP and correlative measurements are well within required +/- 10% between 18 and 42 km. In the upper stratosphere and lower mesosphere (>43 km) LP tends to have a negative bias. We find larger biases in the lower stratosphere and upper troposphere, but LP ozone retrievals have significantly improved in version 2.5 compared to version 2 due to the implemented aerosol correction. In the northern high latitudes we observe larger biases between 20 and 32 km due to the remaining thermal sensitivity issue. Our analysis shows that LP ozone retrievals agree well with the correlative satellite observations in characterizing vertical, spatial and temporal ozone distribution associated with natural processes, like the seasonal cycle and quasi-biennial oscillations. We found a small positive drift approx. 0.5%/yr in the LP ozone record against MLS and OSIRIS that is more pronounced at altitudes above 35 km. This pattern in the relative drift is consistent with a possible 100m drift in the LP sensor pointing detected by one of our altitude-resolving methods
    corecore