2,959 research outputs found

    Help-seeking by problem gamblers, friends and families: a focus on gender and cultural groups

    No full text
    This project was commissioned by the ACT Gambling and Racing Commission (GRC) to examine the issue of helpseeking by gamblers, friends and families in the ACT with a focus on cultural and gender issues.This report was commisioned by ACT Gambling and Racing Commissio

    Volatile Analyzer for Lunar Polar Missions

    Get PDF
    One of the major questions remaining for the future exploration of the Moon by humans concerns the presence of volatiles on our nearest neighbor in space. Observational studies, and investigations involving returned lunar samples and using robotic spacecraft infer the existence of volatile compounds particularly water [1]. It seems very likely that a volatile component will be concentrated at the poles in circumstances where low-temperatures exist to provide cryogenic traps. However, the full inventory of species, their concentration and their origin and sources are unknown. Of particular importance is whether abundances are sufficient to act as a resource of consumables for future lunar expeditions especially if a long-term base involving humans is to be established. To address some of these issues requires a lander designed specifically for operation at a high-lunar latitude. A vital part of the payload needs to be a volatile analyzer such as the Gas Analysis Package specifically designed for identification quantification of volatile substances and collecting information which will allow the origin of these volatiles to be identified [1]. The equipment included, particularly the gas analyzer, must be capable of operation in the extreme environmental conditions to be encountered. No accurate information yet exists regarding volatile concentration even for sites closer to the lunar equator (because of contamination). In this respect it will be important to understand (and thus limit) contamination of the lunar surface by extraneous material contributed from a variety of sources. The only data for the concentrations of volatiles at the poles comes from orbiting spacecraft and whilst the levels at high latitudes may be greater than at the equator, the volatile analyzer package under consideration will be designed to operate at the highest specifications possible and in a way that does not compromise the data

    Quantum Computation with Quantum Dots

    Full text link
    We propose a new implementation of a universal set of one- and two-qubit gates for quantum computation using the spin states of coupled single-electron quantum dots. Desired operations are effected by the gating of the tunneling barrier between neighboring dots. Several measures of the gate quality are computed within a newly derived spin master equation incorporating decoherence caused by a prototypical magnetic environment. Dot-array experiments which would provide an initial demonstration of the desired non-equilibrium spin dynamics are proposed.Comment: 12 pages, Latex, 2 ps figures. v2: 20 pages (very minor corrections, substantial expansion), submitted to Phys. Rev.

    Cost-effectiveness of insulin pumps compared with multiple daily injections, both provided with structured education, for adults with type 1 diabetes:a health economic analysis of the Relative Effectiveness of Pumps over Structured Education (REPOSE) randomised controlled trial

    Get PDF
    Objectives To assess the long-term cost-effectiveness of insulin pumps and Dose Adjustment for Normal Eating (pumps+DAFNE) compared with multiple daily insulin injections and DAFNE (MDI+DAFNE) for adults with type 1 diabetes mellitus (T1DM) in the UK. Methods We undertook a cost–utility analysis using the Sheffield Type 1 Diabetes Policy Model and data from the Relative Effectiveness of Pumps over Structured Education (REPOSE) trial to estimate the lifetime incidence of diabetic complications, intervention-based resource use and associated effects on costs and quality-adjusted life years (QALYs). All economic analyses took a National Health Service and personal social services perspective and discounted costs and QALYs at 3.5% per annum. A probabilistic sensitivity analysis was performed on the base case. Further uncertainties in the cost of pumps and the evidence used to inform the model were explored using scenario analyses. Setting Eight diabetes centres in England and Scotland. Participants Adults with T1DM who were eligible to receive a structured education course and did not have a strong clinical indication or a preference for a pump. Intervention Pumps+DAFNE. Comparator MDI+DAFNE. Main outcome measures Incremental costs, incremental QALYs gained and incremental cost-effectiveness ratios (ICERs). Results Compared with MDI+DAFNE, pumps+DAFNE was associated with an incremental discounted lifetime cost of +£18 853 (95% CI £6175 to £31 645) and a gain in discounted lifetime QALYs of +0.13 (95% CI -0.70 to +0.96). The base case mean ICER was £142 195 per QALY gained. The probability of pump+DAFNE being cost-effective using a cost-effectiveness threshold of £20 000 per QALY gained was 14.0%. All scenario and subgroup analyses examined indicated that the ICER was unlikely to fall below £30 000 per QALY gained. Conclusions Our analysis of the REPOSE data suggests that routine use of pumps in adults without an immediate clinical need for a pump, as identified by National Institute for Health and Care Excellence, would not be cost-effective. Trial registration number ISRCTN61215213

    Measurement of Pulmonary Flow Reserve and Pulmonary Index of Microcirculatory Resistance for Detection of Pulmonary Microvascular Obstruction

    Get PDF
    BACKGROUND: The pulmonary microcirculation is the chief regulatory site for resistance in the pulmonary circuit. Despite pulmonary microvascular dysfunction being implicated in the pathogenesis of several pulmonary vascular conditions, there are currently no techniques for the specific assessment of pulmonary microvascular integrity in humans. Peak hyperemic flow assessment using thermodilution-derived mean transit-time (T(mn)) facilitate accurate coronary microcirculatory evaluation, but remain unvalidated in the lung circulation. Using a high primate model, we aimed to explore the use of T(mn) as a surrogate of pulmonary blood flow for the purpose of measuring the novel indices Pulmonary Flow Reserve [PFR = (maximum hyperemic)/(basal flow)] and Pulmonary Index of Microcirculatory Resistance [PIMR = (maximum hyperemic distal pulmonary artery pressure)x(maximum hyperemic T(mn))]. Ultimately, we aimed to investigate the effect of progressive pulmonary microvascular obstruction on PFR and PIMR. METHODS AND RESULTS: Temperature- and pressure-sensor guidewires (TPSG) were placed in segmental pulmonary arteries (SPA) of 13 baboons and intravascular temperature measured. T(mn) and hemodynamics were recorded at rest and following intra-SPA administration of the vasodilator agents adenosine (10-400 microg/kg/min) and papaverine (3-24 mg). Temperature did not vary with intra-SPA sensor position (0.010+/-0.009 v 0.010+/-0.009 degrees C; distal v proximal; p = 0.1), supporting T(mn) use in lung for the purpose of hemodynamic indices derivation. Adenosine (to 200 microg/kg/min) & papaverine (to 24 mg) induced dose-dependent flow augmentations (40+/-7% & 35+/-13% T(mn) reductions v baseline, respectively; p<0.0001). PFR and PIMR were then calculated before and after progressive administration of ceramic microspheres into the SPA. Cumulative microsphere doses progressively reduced PFR (1.41+/-0.06, 1.26+/-0.19, 1.17+/-0.07 & 1.01+/-0.03; for 0, 10(4), 10(5) & 10(6) microspheres; p = 0.009) and increased PIMR (5.7+/-0.6, 6.3+/-1.0, 6.8+/-0.6 & 7.6+/-0.6 mmHg.sec; p = 0.0048). CONCLUSIONS: Thermodilution-derived mean transit time can be accurately and reproducibly measured in the pulmonary circulation using TPSG. Mean transit time-derived PFR and PIMR can be assessed using a TPSG and adenosine or papaverine as hyperemic agents. These novel indices detect progressive pulmonary microvascular obstruction and thus have with a potential role for pulmonary microcirculatory assessment in humans
    • …
    corecore