151 research outputs found

    Prognostic implication of coronary flow reserve in diabetic and nondiabetic patients with negative dipyridamole stress echo by wall motion criteria

    Get PDF
    Objectives: Aim of this prospective, multicenter, observational study was to assess the prognostic value of Doppler echocardiographic derived coronary flow reserve (CFR) in diabetic and nondiabetic patients with known or suspected coronary artery disease (CAD) and negative dipyridamole stress echo. Methods: The study group consisted of 1130 patients (207 diabetics) with known (n=418) or suspected (n=712) CAD and negative stress echo by wall motion criteria. All underwent dipyridamole (up to 0.84 mg/kg over 6\u27) echo with CFR evaluation of left anterior descending artery by Doppler. A value of CFR <2.0 was considered abnormal. Results: CFR was normal in 821 (63%) and abnormal in 309 (27%) patients. During a median follow-up of 16 months, 98 events (8 deaths, 24 STEMI, and 66 NSTEMI) occurred. In addition, 89 patients underwent revascularization and were censored. Multivariable prognostic indicators were abnormal CFR (HR=4.95; 95% CI=3.26-7.50; p<0.0001), antianginal therapy at the time of testing (HR=1.96; 95% CI=1.29-2.98; p=0.002), age (HR=1.02; 95% CI=1.00-1.04; p=0.02), and resting wall motion abnormalities (HR=1.50; 95% CI=1.00-2.25; p=0.05). The 36-month event rate was lower (p<0.0001) for either diabetics and nondiabetics with normal CFR as compard to diabetics and nondiabetics with abnormal CFR (Figure). Conclusion: CFR provides effective prognostic information in diabetic and nondiabetic patients with known or suspected CAD and negative dipyridamole stress echo. In particular, a reduced CFR is associated with worse outcome in both populations

    Vanadyl phthalocyanines on graphene/SiC(0001): toward a hybrid architecture for molecular spin qubits

    Get PDF
    Vanadyl phthalocyanine (VOPc) contains a highly coherent spin S = ½, which is of interest for applications in quantum information. Preservation of long coherence times upon deposition on conductive materials is crucial for use of single-spin in devices. Here, we report a detailed investigation of the structural, electronic and magnetic properties of a hybrid architecture constituted by a monolayer film of VOPc molecules deposited on graphene/SiC(0001). Graphene (Gr) is a two-dimensional conductor with exceptional chemical stability, a property which we exploited here to preserve the spin of VOPc. Low temperature-scanning tunneling microscopy supported by density functional theory (DFT) simulations revealed that VOPc molecules were adsorbed intact on the Gr/SiC(0001) surface in a planar geometry assuming a unique configuration in which the vanadyl group is projected out toward the vacuum, different to that found commonly on other conductive surfaces. Furthermore, X-ray photoelectron spectroscopy and UV-photoelectron spectroscopy (flanked theoretically by DFT) showed that VOPc interact weakly with the Gr/SiC(0001) substrate to preserve its electronic configuration with the unpaired electron located on the V ion. These findings were confirmed by X-ray magnetic circular dichroism, revealing that the S = ½ character of the VOPc assembly on Gr/SiC(0001) was preserved, in agreement with the theoretical prediction. Hence, molecules could be adsorbed and used as qubits on substrates of technological importance, such as graphene. This new hybrid architecture could be employed for local investigation of static and dynamic spin properties and as molecular qubits for spintronic applications

    Stress echo 2020: The international stress echo study in ischemic and non-ischemic heart disease

    Get PDF
    Abstract Background Stress echocardiography (SE) has an established role in evidence-based guidelines, but recently its breadth and variety of applications have extended well beyond coronary artery disease (CAD). We lack a prospective research study of SE applications, in and beyond CAD, also considering a variety of signs in addition to regional wall motion abnormalities. Methods In a prospective, multicenter, international, observational study design, > 100 certified high-volume SE labs (initially from Italy, Brazil, Hungary, and Serbia) will be networked with an organized system of clinical, laboratory and imaging data collection at the time of physical or pharmacological SE, with structured follow-up information. The study is endorsed by the Italian Society of Cardiovascular Echography and organized in 10 subprojects focusing on: contractile reserve for prediction of cardiac resynchronization or medical therapy response; stress B-lines in heart failure; hypertrophic cardiomyopathy; heart failure with preserved ejection fraction; mitral regurgitation after either transcatheter or surgical aortic valve replacement; outdoor SE in extreme physiology; right ventricular contractile reserve in repaired Tetralogy of Fallot; suspected or initial pulmonary arterial hypertension; coronary flow velocity, left ventricular elastance reserve and B-lines in known or suspected CAD; identification of subclinical familial ..

    Feasibility, safety and tolerability of accelerated dobutamine stress echocardiography

    Get PDF
    A continuous infusion of a single high dose of dobutamine has been, recently, suggested as a simple and effective protocol of stress echocardiography. The present study assesses the feasibility, safety, and tolerability of an accelerated dobutamine stress protocol performed in patients with suspected or known coronary artery disease. Two hundred sixty five consecutive patients underwent accelerated dobutamine stress echocardiography: the dobutamine was administered at a constant dose of 50 μg/kg/min for up to 10 minutes. The mean weight-adjusted cumulative dose of dobutamine used was 330 ± 105.24 μg/kg. Total duration of dobutamine infusion was 6.6 ± 2.1 min. Heart rate rose from 69.9 ± 12.1 to 123.1 ± 22.1 beats/min at peak with a concomitant change in systolic blood pressure (127.6 ± 18.1 vs. 167.6 ± 45.0 mmHg). Dobutamine administration produced a rapid increase in heart rate (9.4 ± 5.9 beats/min2). The side effects were similar to those described with the standard protocol; the most common were frequent premature ventricular complexes (21.5%), frequent premature atrial complexes (1.5%) and non sustained ventricular tachycardia (1.5%); among non cardiac symptoms the most frequent were nausea (3.4%), headache (1.1%) and symptomatic hypotension (1.1%). No major side effects were observed during the test. Our data demonstrate that a continous infusion of a single high dose of dobutamine is a safe and well tolerated method of performing stress echocardiography in patients with suspected or known coronary artery disease. This new protocol requires the administration of lower cumulative dobutamine dose than standard protocol and results in a significant reduction in test time

    Anti-ischemic therapy and stress testing: pathophysiologic, diagnostic and prognostic implications

    Get PDF
    Anti-ischemic therapy, in particular beta-blockers, is the most commonly employed drug for the control of myocardial ischemia in patients with stable coronary artery disease. Its widespread use also in patients with suspected coronary artery disease has important practical, clinical diagnostic and prognostic implications because diagnostic tests are heavily influenced by its effects. In the present review, the pathophysiological mechanisms of ischemia protection by antianginal therapy are described. Not all stressors are created equal in front of the different classes of antianginal drugs and on their turn the different classes of drugs exert different levels of protection on inducible ischemia. Several clinical implications can be drawn: From the diagnostic viewpoint antianginal therapy decreases test sensitivity, offsetting the real ischemic burden for a too high percentage of false negative tests. From the prognostic viewpoint test positivity in medical therapy identifies a group of subjects at higher risk of experiencing cardiac death and positivity on medical therapy can be considered a parameter of ischemia severity. Nonetheless in patients with known coronary artery disease the ability of antianginal therapy to modify the ischemic threshold at stress testing represent a powerful means to assess therapy efficacy. From a practical viewpoint, the use of antianginal therapy at time of testing has advantages and disadvantages which are largely dependent on the purpose a test is performed: if the purpose of testing is to diagnose ischemia, it should be performed in the absence of antianginal medications. If the purpose of testing is to assess the protective effects of antianginal therapy, the test should be performed on medications

    Assessment of coronary artery disease and calcified coronary plaque burden by computed tomography in patients with and without diabetes mellitus

    Get PDF
    Purpose: To compare the coronary atherosclerotic burden in patients with and without type-2 diabetes using CT Coronary Angiography (CTCA). Methods and Materials: 147 diabetic (mean age: 65 ± 10 years; male: 89) and 979 nondiabetic patients (mean age: 61 ± 13 years; male: 567) without a history of coronary artery disease (CAD) underwent CTCA. The per-patient number of diseased coronary segments was determined and each diseased segment was classified as showing obstructive lesion (luminal narrowing >50%) or not. Coronary calcium scoring (CCS) was assessed too. Results: Diabetics showed a higher number of diseased segments (4.1 ± 4.2 vs. 2.1 ± 3.0; p 400 (p < 0.001), obstructive CAD (37% vs. 18% of patients; p < 0.0001), and fewer normal coronary arteries (20% vs. 42%; p < 0.0001), as compared to nondiabetics. The percentage of patients with obstructive CAD paralleled increasing CCS in both groups. Diabetics with CCS ≤ 10 had a higher prevalence of coronary plaque (39.6% vs. 24.5%, p = 0.003) and obstructive CAD (12.5% vs. 3.8%, p = 0.01). Among patients with CCS ≤ 10 all diabetics with obstructive CAD had a zero CCS and one patient was asymptomatic. Conclusions: Diabetes was associated with higher coronary plaque burden. The present study demonstrates that the absence of coronary calcification does not exclude obstructive CAD especially in diabetics

    The prognostic value of dobutamine stress echocardiography amongst British Indian Asian and Afro-Caribbean patients: a comparison with European white patients

    Get PDF
    Background The incidence of cardiovascular disease is considerably disparate among different racial and ethnic populations. While dobutamine stress echocardiography (DSE) has been shown to be useful in Caucasian patients, its role among ethnic minority groups remains unclear. This study aimed to investigate the prognostic importance of DSE in three ethnic groups in the UK. Methods DSE was performed on 6231 consecutive patients. After exclusions, 5329 patients formed the study (2676 [50.2 %] Indian Asian, 2219 [41.6 %] European white and 434 [8.1 %] Afro-Caribbean). Study outcome measures were non-fatal cardiac events (NFCE) and all-cause mortality. Results There were 849 (15.9 %) NFCE and 1365 (25.6 %) deaths over a median follow-up period of 4.6 years. In total 1174 (22 %) patients had inducible myocardial ischaemia during DSE, 859 (16.1 %) had fixed wall motion abnormalities and 3645 (68.4 %) patients had a normal study. Ethnicity did not predict events. Among the three ethnic groups, ischaemia on DSE was associated with 2 to 2.5 times the risk of non-fatal cardiac events and 1.2 to 1.4 times the risk of all-cause mortality. Peak wall motion score index was the strongest independent predictor of non-fatal cardiac events and all-cause mortality in all groups. The C statistic for the prediction of NFCE and all-cause mortality were significantly higher when DSE parameters were added to the standard risk factors for all ethnic groups. Conclusions DSE is a strong predictor of NFCE and all-cause mortality and provides predictive information beyond that provided by standard risk factors in three major racial and ethnic groups. No major differences among racial and ethnic groups in the predictive value of DSE was detected
    • …
    corecore