80 research outputs found

    Clinical outcomes of all‐ceramic single crowns and fixed dental prostheses supported by ceramic implants: A systematic review and meta‐analyses

    Full text link
    Objective: To analyze the clinical outcomes of all-ceramic single crowns (SCs) and fixed dental prostheses (FDPs) supported by ceramic implants. Materials and methods: Based on a focused question and customized PICO framework, electronic (Medline/EMBASE/Cochrane) and manual searches for studies reporting the clinical outcomes of all-ceramic SCs and FDPs supported by ceramic implants ≥12 months were performed. The primary outcomes were reconstruction survival and the chipping proportion. The secondary outcomes were implant survival, technical complications, and patient-related outcome measurements. Meta-analyses were performed after 1, 2, and 5 years using random-effect meta-analyses. Results: Eight of the 1,403 initially screened titles and 55 full texts were included. Five reported on monolithic lithium disilicate (LS2) SCs, one on veneered zirconia SCs, and two on veneered zirconia SCs and FDPs, which reported all on cement-retained reconstructions (mean observation: 12.0-61.0 months). Meta-analyses estimated a 5-year survival rate of 94% (95% confidence interval [CI]: 82%-100%) for overall implant survival. Reconstruction survival proportions after 5 years were: monolithic LS2, 100% (95%CI: 95%-100%); veneered zirconia SCs, 89% (95%CI: 62%-100%); and veneered zirconia FDPs 94% (95%CI: 81%-100%). The chipping proportion after 5 years was: monolithic LS2, 2% (95%CI: 0%-11%); veneered zirconia SCs, 38% (95%CI: 24%-54%); and veneered zirconia FDPs, 57% (95%CI: 38%-76%). Further outcomes were summarized descriptively. Conclusions: Due to the limited data available, only tendencies could be identified. All-ceramic reconstructions supported by ceramic implants demonstrated promising survival rates after mid-term observation. However, high chipping proportions of veneered zirconia SCs and, particularly, FDPs diminished the overall outcome. Monolithic LS2 demonstrated fewer clinical complications. Monolithic reconstructions could be a valid treatment option for ceramic implants. Keywords: ceramics; dental implants; implant-supported dental prosthesis; meta-analysis; survival analysis; systematic review; treatment outcome; zirconia

    Automated tracing of myelinated axons and detection of the nodes of Ranvier in serial images of peripheral nerves

    Get PDF
    The development of realistic neuroanatomical models of peripheral nerves for simulation purposes requires the reconstruction of the morphology of the myelinated fibres in the nerve, including their nodes of Ranvier. Currently, this information has to be extracted by semimanual procedures, which severely limit the scalability of the experiments. In this contribution, we propose a supervised machine learning approach for the detailed reconstruction of the geometry of fibres inside a peripheral nerve based on its high-resolution serial section images. Learning from sparse expert annotations, the algorithm traces myelinated axons, even across the nodes of Ranvier. The latter are detected automatically. The approach is based on classifying the myelinated membranes in a supervised fashion, closing the membrane gaps by solving an assignment problem, and classifying the closed gaps for the nodes of Ranvier detection. The algorithm has been validated on two very different datasets: (i) rat vagus nerve subvolume, SBFSEM microscope, 200 × 200 × 200 nm resolution, (ii) rat sensory branch subvolume, confocal microscope, 384 × 384 × 800 nm resolution. For the first dataset, the algorithm correctly reconstructed 88% of the axons (241 out of 273) and achieved 92% accuracy on the task of Ranvier node detection. For the second dataset, the gap closing algorithm correctly closed 96.2% of the gaps, and 55% of axons were reconstructed correctly through the whole volume. On both datasets, training the algorithm on a small data subset and applying it to the full dataset takes a fraction of the time required by the currently used semiautomated protocols. Our software, raw data and ground truth annotations are available at http://hci.iwr.uni-heidelberg.de/Benchmarks/. The development version of the code can be found at https://github.com/RWalecki/ATMA

    Sensory bedside testing: a simple stratification approach for sensory phenotyping

    Get PDF
    Introduction: Stratification of patients according to the individual sensory phenotype has been suggested a promising method to identify responders for pain treatment. However, many state-of-the-art sensory testing procedures are expensive or time-consuming. Objectives: Therefore, this study aimed to present a selection of easy-to-use bedside devices. Methods: In total, 73 patients (39 m/34 f) and 20 controls (11 m/9 f) received a standardized laboratory quantitative sensory testing (QST) and a bedside-QST. In addition, 50 patients were tested by a group of nonexperienced investigators to address the impact of training. The sensitivity, specificity, and receiver-operating characteristics were analyzed for each bedside-QST parameter as compared to laboratory QST. Furthermore, the patients’ individual sensory phenotype (ie, cluster) was determined using laboratory QST, to select bedside-QST parameters most indicative for a correct cluster allocation. Results: The bedside-QST parameters “loss of cold perception to 22˚C metal,” “hypersensitivity towards 45˚C metal,” “loss of tactile perception to Q-tip and 0.7 mm CMS hair,” as well as “the allodynia sum score” indicated good sensitivity and specificity (ie, ≳70%). Results of interrater variability indicated that training is necessary for individual parameters (ie, CMS 0.7). For the cluster assessment, the respective bedside quantitative sensory testing (QST) parameter combination indicated the following agreements as compared to laboratory QST stratification: excellent for “sensory loss” (area under the curve [AUC] 5 0.91), good for “thermal hyperalgesia” (AUC 5 0.83), and fair for “mechanical hyperalgesia” (AUC 5 0.75). Conclusion: This study presents a selection of bedside parameters to identify the individual sensory phenotype as cost and time efficient as possible

    An engineering perspective of ceramics applied in dental reconstructions

    Get PDF
    The demands for dental materials continue to grow, driven by the desire to reach a better performance than currently achieved by the available materials. In the dental restorative ceramic field, the structures evolved from the metal-ceramic systems to highly translucent multilayered zirconia, aiming not only for tailored mechanical properties but also for the aesthetics to mimic natural teeth. Ceramics are widely used in prosthetic dentistry due to their attractive clinical properties, including high strength, biocompatibility, chemical stability, and a good combination of optical properties. Metal-ceramics type has always been the golden standard of dental reconstruction. However, this system lacks aesthetic aspects. For this reason, efforts are made to develop materials that met both the mechanical features necessary for the safe performance of the restoration as well as the aesthetic aspects, aiming for a beautiful smile. In this field, glass and high-strength core ceramics have been highly investigated for applications in dental restoration due to their excellent combination of mechanical properties and translucency. However, since these are recent materials when compared with the metal-ceramic system, many studies are still required to guarantee the quality and longevity of these systems. Therefore, a background on available dental materials properties is a starting point to provoke a discussion on the development of potential alternatives to rehabilitate lost hard and soft tissue structures with ceramic-based tooth and implant-supported reconstructions. This review aims to bring the most recent materials research of the two major categories of ceramic restorations: ceramic-metal system and all-ceramic restorations. The practical aspects are herein presented regarding the evolution and development of materials, technologies applications, strength, color, and aesthetics. A trend was observed to use high-strength core ceramics type due to their ability to be manufactured by CAD/CAM technology. In addition, the impacts of COVID-19 on the market of dental restorative ceramics are presented

    Stratifying patients with peripheral neuropathic pain based on sensory profiles : algorithm and sample size recommendations

    Get PDF
    In a recent cluster analysis, it has been shown that patients with peripheral neuropathic pain can be grouped into 3 sensory phenotypes based on quantitative sensory testing profiles, which are mainly characterized by either sensory loss, intact sensory function and mild thermal hyperalgesia and/or allodynia, or loss of thermal detection and mild mechanical hyperalgesia and/or allodynia. Here, we present an algorithm for allocation of individual patients to these subgroups. The algorithm is nondeterministic-ie, a patient can be sorted to more than one phenotype-and can separate patients with neuropathic pain from healthy subjects (sensitivity: 78%, specificity: 94%). We evaluated the frequency of each phenotype in a population of patients with painful diabetic polyneuropathy (n = 151), painful peripheral nerve injury (n = 335), and postherpetic neuralgia (n = 97) and propose sample sizes of study populations that need to be screened to reach a subpopulation large enough to conduct a phenotype-stratified study. The most common phenotype in diabetic polyneuropathy was sensory loss (83%), followed by mechanical hyperalgesia (75%) and thermal hyperalgesia (34%, note that percentages are overlapping and not additive). In peripheral nerve injury, frequencies were 37%, 59%, and 50%, and in postherpetic neuralgia, frequencies were 31%, 63%, and 46%. For parallel study design, either the estimated effect size of the treatment needs to be high (> 0.7) or only phenotypes that are frequent in the clinical entity under study can realistically be performed. For crossover design, populations under 200 patients screened are sufficient for all phenotypes and clinical entities with a minimum estimated treatment effect size of 0.5.Peer reviewe

    Evaluation and discussion of handmade face-masks and commercial diving-equipment as personal protection in pandemic scenarios.

    No full text
    ObjectivePandemic scenarios like the current Corona outbreak show the vulnerability of both globalized markets and just-in-time production processes for urgent medical equipment. Even usually cheap personal protection equipment becomes excessively expensive or is not deliverable at all. To avoid dangerous situations especially to medical professionals, but also to affected patients, 3D-printer and maker-communities have teamed up to develop and print shields, masks and adapters to help the medical personnel. In this study, we investigate three home-made respiratory masks for filter and protection efficacy and discuss the results and legal aspects.Materials and methodsA home-printed respiratory mask with a commercial filter, a scuba-diving mask with a commercial filter and a mask sewn from a vacuum cleaner bag were investigated with 99mTc-labeled NaCl-aerosol, and the respective filter-efficacy was measured under a scintigraphic camera.ResultsThe sewn mask from a vacuum cleaner bag had a filter efficacy of 69.76%, the 3D-printed mask of 39.27% and the scuba-diving mask of 85.07%.ConclusionHome-printed personal protection equipment can be a-yet less efficient-alternative against aerosol in case professional masks are not available, but legal aspects of their use and distribution have to be kept in mind in order to avoid compensation claims

    Brain of the sheep

    No full text
    <p>STL-Model of the sheep's brain derived from a T2 MRI dataset.</p

    Mastication after craniotomy: pilot assessment of postoperative oral health-related quality of life

    No full text
    Background!#!Neurosurgical approaches to the brain often require the mobilization of the temporal muscle. Many patients complain of postoperative pain, atrophy, reduced mouth opening, and masticatory problems. Although the pterional, frontolateral-extended-pterional, and temporal craniotomies are the most frequently used approaches in neurosurgery, a systematic assessment of the postoperative oral health-related quality of life has never been performed so far. This study evaluates the oral health-related quality of life of patients after pterional, frontolateral-extended-pterional, or temporal craniotomy using a validated and standardized dental questionnaire, compares the results with the normal values of the general population, and investigates whether this questionnaire is sensitive to changes caused by surgical manipulation of the temporal muscle.!##!Methods!#!The 'Oral Health Impact Profile' (OHIP14) is a validated questionnaire to assess the oral health-related quality of life. It asks the patients to assess their oral health situation within the past 7 days in 14 questions. Possible answers range from 0 (never) to 4 (very often). Sixty patients with benign intracranial processes operated through a lateral cranial approach were included. The questionnaire was answered before surgery (baseline) and 3 months and 15 months after surgery.!##!Results!#!Overall, postoperative OHIP scores increase significantly after 3 months and decrease after 15 months, but not to preoperative values. No factors can be identified which show a considerable relationship with the postoperative OHIP score.!##!Conclusions!#!Postoperative impairment of mouth opening and pain during mastication can be observed 3 to 15 months after surgery and sometimes cause feedback from patients and their dentists. However, in line with existing literature, these complaints decrease with time. The study shows that the OHIP questionnaire is sensitive to changes caused by surgical manipulation of the temporal muscle and can therefore be used to investigate the influence of surgical techniques on postoperative complaints. Postoperatively, patients show worse OHIP scores than the general population, demonstrating that neurosurgical cranial approaches negatively influence the patient's oral health-related wellbeing. Larger studies using the OHIP questionnaire should evaluate if postoperative physical therapy, speech therapy, or specialized rehabilitation devices can improve the masticatory impairment after craniotomy.!##!Trial registration!#!Clinical trial register: DRKS00011096

    Monolithic Polymer-Infiltrated Ceramic Network CAD/CAM Single Crowns: Three-Year Mid-Term Results of a Prospective Clinical Study

    No full text
    Purpose: To evaluate the clinical outcomes of monolithic CAD/CAM-fabricated polymer-infiltrated ceramic network (PICN) single crowns (SC) after 3 years. Materials and Methods: A total of 34 patients who received 76 single crowns were included in this cohort study. Full-coverage crown preparation with reduced thickness (1.0 to 1.5 mm) was applied. All monolithic PICN SCs (VITA Enamic) were manufactured using a CAD/CAM system and adhesively seated. Clinical follow-up evaluations were performed at 6, 12, 24, and 36 months after insertion using modified United States Public Health Service (USPHS) criteria. Kaplan-Meier survival and success methods were applied to calculate absolute and relative failures. To determine effects of time and restoration, a mixed logit model was adjusted for the modified USPHS criteria (P < .05). Results: PICN SCs revealed an estimated Kaplan-Meier survival rate of 93.9% after 3 years. Four clinically unacceptable fractures occurred, which resulted in replacement of the affected SCs. Neither secondary caries nor debonding were recorded. The 3-year Kaplan-Meier success rate was 92.7%. Significant increases in marginal discoloration (P = .0002) and surface roughness (P < .0001) were noted over time. Color match, anatomical form, and marginal adaptation remained favorable over the given observation period. Conclusion: PICN CAD/CAM crowns with reduced thickness showed acceptable survival and success rates over a service time of 36 months. However, extended clinical follow-up periods are needed to evaluate the long-term performance
    corecore