277 research outputs found

    Veterinary student competence in equine lameness recognition and assessment: a mixed methods study

    Get PDF
    The development of perceptual skills is an important aspect of veterinary education. The authors investigated veterinary student competency in lameness evaluation at two stages, before (third year) and during (fourth/fifth year) clinical rotations. Students evaluated horses in videos, where horses were presented during trot on a straight line and in circles. Eye-tracking data were recorded during assessment on the straight line to follow student gaze. On completing the task, students filled in a structured questionnaire. Results showed that the experienced students outperformed inexperienced students, although even experienced students may classify one in four horses incorrectly. Mistakes largely arose from classifying an incorrect limb as lame. The correct detection of sound horses was at chance level. While the experienced student cohort primarily looked at upper body movement (head and sacrum) during lameness assessment, the inexperienced cohort focused on limb movement. Student self-assessment of performance was realistic, and task difficulty was most commonly rated between 3 and 4 out of 5. The inexperienced students named a considerably greater number of visual lameness features than the experienced students. Future dedicated training based on the findings presented here may help students to develop more reliable lameness assessment skills

    Finite Element Analysis Comparing a PEEK Posterior Fixation Device Versus Pedicle Screws for Lumbar Fusion

    Get PDF
    BACKGROUND: Pedicle screw loosening and breakage are common causes of revision surgery after lumbar fusion. Thus, there remains a continued need for supplemental fixation options that offer immediate stability without the associated failure modes. This finite element analysis compared the biomechanical properties of a novel cortico-pedicular posterior fixation (CPPF) device with those of a conventional pedicle screw system (PSS). METHODS: The CPPF device is a polyetheretherketone strap providing circumferential cortical fixation for lumbar fusion procedures via an arcuate tunnel. Using a validated finite element model, we compared the stability and load transfer characteristics of CPPF to intact conditions under a 415 N follower load and PSS conditions under a 222 N preload. Depending on the instrumented levels, two different interbody devices were used: a lateral lumbar interbody device at L4-5 or an anterior lumbar interbody device at L5-S1. Primary outcomes included range of motion of the functional spinal units and anterior load transfer, defined as the total load through the disk and interbody device after functional motion and follower load application. RESULTS: Across all combinations of interbody devices and lumbar levels evaluated, CPPF consistently demonstrated significant reductions in flexion (ranging from 90 to 98%), extension (ranging from 88 to 94%), lateral bending (ranging from 75 to 80%), and torsion (ranging from 77 to 86%) compared to the intact spine. Stability provided by the CPPF device was comparable to PSS in all simulations (range of motion within 0.5 degrees for flexion-extension, 0.6 degrees for lateral bending, and 0.5 degrees for torsion). The total anterior load transfer was higher with CPPF versus PSS, with differences across all tested conditions ranging from 128 to 258 N during flexion, 89-323 N during extension, 135-377 N during lateral bending, 95-258 N during torsion, and 82-250 N during standing. CONCLUSION: Under the modeled conditions, cortico-pedicular fixation for supplementing anterior or lateral interbody devices between L4 and S1 resulted in comparable stability based on range of motion measures and less anterior column stress shielding based on total anterior load transfer measures compared to PSS. Clinical studies are needed to confirm these finite element analysis findings

    Reliability of videotaped observational gait analysis in patients with orthopedic impairments

    Get PDF
    BACKGROUND: In clinical practice, visual gait observation is often used to determine gait disorders and to evaluate treatment. Several reliability studies on observational gait analysis have been described in the literature and generally showed moderate reliability. However, patients with orthopedic disorders have received little attention. The objective of this study is to determine the reliability levels of visual observation of gait in patients with orthopedic disorders. METHODS: The gait of thirty patients referred to a physical therapist for gait treatment was videotaped. Ten raters, 4 experienced, 4 inexperienced and 2 experts, individually evaluated these videotaped gait patterns of the patients twice, by using a structured gait analysis form. Reliability levels were established by calculating the Intraclass Correlation Coefficient (ICC), using a two-way random design and based on absolute agreement. RESULTS: The inter-rater reliability among experienced raters (ICC = 0.42; 95%CI: 0.38–0.46) was comparable to that of the inexperienced raters (ICC = 0.40; 95%CI: 0.36–0.44). The expert raters reached a higher inter-rater reliability level (ICC = 0.54; 95%CI: 0.48–0.60). The average intra-rater reliability of the experienced raters was 0.63 (ICCs ranging from 0.57 to 0.70). The inexperienced raters reached an average intra-rater reliability of 0.57 (ICCs ranging from 0.52 to 0.62). The two expert raters attained ICC values of 0.70 and 0.74 respectively. CONCLUSION: Structured visual gait observation by use of a gait analysis form as described in this study was found to be moderately reliable. Clinical experience appears to increase the reliability of visual gait analysis

    Limited morbidity and possible radiographic benefit of C2

    Get PDF
    Background: The study aims to evaluate differences in alignment and clinical outcomes between surgical cervical deformity (CD) patients with a subaxial upper-most instrumented vertebra (UIV) and patients with a UIV at C2. Use of CD-corrective instrumentation in the subaxial cervical spine is considered risky due to narrow subaxial pedicles and vertebral artery anatomy. While C2 fixation provides increased stability, the literature lacks guidelines indicating extension of CD-corrective fusion from the subaxial spine to C2. Methods: Included: operative CD patients with baseline (BL) and 1-year postop (1Y) radiographic data, cervical UIV ≥ C2. Patients were grouped by UIV: C2 or subaxial (C3-C7) and propensity score matched (PSM) for BL cSVA. Mean comparison tests assessed differences in BL and 1Y patient-related, radiographic, and surgical data between UIV groups, and BL-1Y changes in alignment and clinical outcomes. Results: Following PSM, 31 C2 UIV and 31 subaxial UIV patients undergoing CD-corrective surgery were included. Groups did not differ in BL comorbidity burden (P=0.175) or cSVA (P=0.401). C2 patients were older (64 Conclusions: C2 UIV patients showed similar cervical range of motion and baseline to 1-year functional outcomes as patients with a subaxial UIV. C2 UIV patients also showed greater baseline to 1-year horizontal gaze improvement and had complication profiles similar to subaxial UIV patients, demonstrating the radiographic benefit and minimal functional loss associated with extending fusion constructs to C2. In the treatment of adult cervical deformities, extension of the reconstruction construct to the axis may allow for certain clinical benefits with less morbidity than previously acknowledged

    Exploring the use of Kratom (Mitragyna speciosa) via the YouTube Data Tool: a Novel Netnographic Analysis

    Get PDF
    © 2021 The Authors. Published by Elsevier Ltd on behalf of International Society for the Study of Emerging Drugs. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/ )Kratom (Mitragyna speciosa) is a tree native to Southeast Asia with long history of traditional medicinal use. The aim of this study was to investigate the nature of self-reported exported experiences as shared on YouTube™ videos. A total of 500 videos with 19,478,180 views and 134, 863 comments emerged from the data scrape extracted via the YouTube Data Tool. 12 out of the 16 most viewed videos emerged from our searches were manually processed and selected for inductive thematic analysis. Kratom use for the self-medication of a number of health conditions was described in the videos, including for opioid dependence/addiction (83.4%), pain (75%), anxiety (67%) and depression (42%), substance use problems (42%) as well as for energy boosting (50%), mood elevation (25%) and nootropic effects (25%). Although most of the described experiences were positive (58%), side-effects such as dependence and withdrawal (50%), nausea (42%), loss of appetite (25%), sedation (25%), loss of motivation (16.7%), headache (16.7%), drowsiness (16.7%), dry mouth and frequent urination (16.7%) were also reported and associated in 25% of the cases to chronic ingestions. Overall, our findings would show that Kratom is used more frequently for self-medication, than as a recreational drug. It also supports the need for more controlled clinical studies to better assess the safety and the efficacy of its use in a therapeutic context.Peer reviewe

    Improving the sensitivity of the hop index in patients with an ACL deficient knee by transforming the hop distance scores

    Get PDF
    BACKGROUND: The one leg hop for distance is one of the most commonly employed functional tests utilized in the evaluation of the ACL deficient and reconstructed patient. While the reliability of the hop test scores has been well established, validity studies have revealed low sensitivity rates in detecting functional limitations using the hop index (the ratio or percentage of limb performance). However, the impact of the inherent limitations associated with the hop index have not been investigated to date. One specific limitation relates to the impact of the differences in the underlying hop distance scores. Therefore, this pilot study set out to determine: 1) the impact that between limb differences in hop distance has on the sensitivity of the hop index in detecting functional limitations and; 2) whether a logarithmic transformation of the underlying hop distance scores improves the sensitivity of the hop index. METHODS: A cross sectional design involving the evaluation of one leg hop for distance performance in a consecutive sample of 10 ACL deficient males with an isolated ACL tear awaiting reconstructive surgery and nine gender, age-matched controls. RESULTS: In the ACL deficient, the hop index was associated with the distance hopped on the non-injured limb (r = -0.66, p = 0.04) but not on the injured limb. Transformation (logarithmic) of the hop distance scores and re-calculation of the hop index using the transformed scores increased the sensitivity of the hop index in the detection of functional limitations from 20 to 60% and 50 to 70% using the normal limb symmetry reference norms of ≥ 85% and 90% respectively. CONCLUSION: The distance hopped on the non-injured limb is a critical factor in detecting functional limitations using the hop index in patients with an ACL deficient knee. Logarithmic transformation of the hop distance scores minimizes the effect of the arithmetic differences between limbs however; the sensitivity of the hop index in detecting abnormal limb symmetry remains low
    • …
    corecore