2,651 research outputs found

    Impacts of food-based enrichment on behaviour and physiology of male greater rheas (Rhea Americana, Rheidae, Aves)

    Get PDF
    Distress can be defined as a biological response of an individual to long-term threats to its homeostasis and it should be avoided from an animal welfare perspective. High levels of stress hormones and the expression of abnormal behaviours are responses normally observed in distressed animals. Captive environments can provoke distress, especially when inappropriate stimuli are provided to the animals. The concomitant use of behavioural and non-invasive hormonal measures is a means to evaluate captive animal welfare. Environmental enrichment is a tool that can reduce distress and minimize the expression of abnormal behaviour in captive animals. The aim of this study was to evaluate greater rheas’ responses (behavioral and hormonal) to food-based enrichment. Three birds from the Belo Horizonte Zoo, Brazil were studied. The study was divided into three phases (baseline, enrichment and post-enrichment): fruits scattered around the birds’ enclosure were used as enrichment. Behaviour and faecal sampling were undertaken in all phases of the study. Abnormal behaviours and faecal glucocorticoid metabolites (GCM) levels showed significant reduction during the environmental enrichment phase, and a significative positive correlation between GCM production and abnormal pacing was observed. From the results of this study, we conclude that the use of food as environmental enrichment should be encouraged because of its positive effects on animal welfare. Besides, studies with larger groups of greater rheas, with individuals of both sexes, should also be encouraged to evaluate if the results found in this pilot study are consistent and can be generalized to the species

    Low-cost reusable instrumentation for laparoendoscopic single-site nephrectomy: assessment in a porcine model

    Get PDF
    PURPOSE: To test different sets of prebent instruments and a new reusable access device for laparoendoscopic single-site (LESS) surgery. MATERIALS AND METHODS: Three surgeons with previous experience in LESS performed 12 nephrectomies in six pigs. In all procedures, a multichannel access device (X-CONE) and a 5-mm extra-long telescope were used. Four sets of prebent instruments with different profiles (S-portal) were tested: Standard (one straight scissors and one curved grasper), Cuschieri, Carus, and Leroy set (each of them consisting of two curved instruments with different configurations). Assessment was performed based on both objective (procedure time; time to manage the pedicle; time to free kidney) and subjective parameters (entry/exit of instruments; triangulation; dissection up/down; dissection lateral; retraction; interdependence). The subjective assessment tool used was a Likert type scale (1 = easy to 5 = prohibitive). The access device was assessed by using objective (time to complete insertion of device after skin incision) and subjective (significant air leakage, movement constraint) parameters. RESULTS: Time to insertion of the X-CONE was <1 minute in all the cases. Surgeons reported significant insufflant leakage in 58% of cases. The procedure was completed in 10/12 (83%) cases. Mean operative time was 8.3 ± 4.2 minutes, being lower for the Carus group (4.5 min) and higher for the standard group (13 min). Among the different sets, the standard one obtained the best mean scores for all subjective parameters. CONCLUSIONS: X-CONE allows easy abdominal access, and its reusable properties represent cost savings for LESS compared with disposable devices. Prebent instruments might also represent attractive low-cost tools for LESS

    Low-cost reusable instrumentation for laparoendoscopic single-site nephrectomy: assessment in a porcine model

    Get PDF
    PURPOSE: To test different sets of prebent instruments and a new reusable access device for laparoendoscopic single-site (LESS) surgery. MATERIALS AND METHODS: Three surgeons with previous experience in LESS performed 12 nephrectomies in six pigs. In all procedures, a multichannel access device (X-CONE) and a 5-mm extra-long telescope were used. Four sets of prebent instruments with different profiles (S-portal) were tested: Standard (one straight scissors and one curved grasper), Cuschieri, Carus, and Leroy set (each of them consisting of two curved instruments with different configurations). Assessment was performed based on both objective (procedure time; time to manage the pedicle; time to free kidney) and subjective parameters (entry/exit of instruments; triangulation; dissection up/down; dissection lateral; retraction; interdependence). The subjective assessment tool used was a Likert type scale (1 = easy to 5 = prohibitive). The access device was assessed by using objective (time to complete insertion of device after skin incision) and subjective (significant air leakage, movement constraint) parameters. RESULTS: Time to insertion of the X-CONE was <1 minute in all the cases. Surgeons reported significant insufflant leakage in 58% of cases. The procedure was completed in 10/12 (83%) cases. Mean operative time was 8.3 ± 4.2 minutes, being lower for the Carus group (4.5 min) and higher for the standard group (13 min). Among the different sets, the standard one obtained the best mean scores for all subjective parameters. CONCLUSIONS: X-CONE allows easy abdominal access, and its reusable properties represent cost savings for LESS compared with disposable devices. Prebent instruments might also represent attractive low-cost tools for LESS

    Evaluation of rK39 rapid diagnostic tests for canine visceral leishmaniasis : longitudinal study and meta-analysis

    Get PDF
    Canine visceral leishmaniasis is a vector-borne disease caused by the intracellular parasite Leishmania infantum. It is an important veterinary disease, and dogs are also the main animal reservoir for human infection. The disease is widespread in the Mediterranean area, and parts of Asia and South and Central America, and is potentially fatal in both dogs and humans unless treated. Diagnosis of canine infections requires serological or molecular tests. Detection of infection in dogs is important prior to treatment, and in epidemiological studies and control programmes, and a sensitive and specific rapid diagnostic test would be very useful. Rapid diagnostic tests (RDTs) have been developed, but their diagnostic performance has been reported to be variable. We evaluated the sensitivity of a RDT based on serological detection of the rK39 antigen in a cohort of naturally infected Brazilian dogs. The sensitivity of the test to detect infection was relatively low, but increased with time since infection and the severity of infection. We then carried out a meta-analysis of published studies of rK39 RDTs, evaluating the sensitivity to detect disease and infection. The results suggest that rK39 RDTs may be useful in a veterinary clinical setting, but the sensitivity to detect infection is too low for operational control programmes

    Hybrid endoscopic thymectomy : combined transesophageal and transthoracic approach in a survival porcine model with cadaver assessment

    Get PDF
    BACKGROUND: Video-assisted thoracoscopic surgery thymectomy has been used in the treatment of Myastenia Gravis and thymomas (coexisting or not). In natural orifice transluminal endoscopic surgery, new approaches to the thorax are emerging as alternatives to the classic transthoracic endoscopic surgery. The aim of this study was to assess the feasibility and reliability of hybrid endoscopic thymectomy (HET) using a combined transthoracic and transesophageal approach. METHODS: Twelve consecutive in vivo experiments were undertaken in the porcine model (4 acute and 8 survival). The same procedure was assessed in a human cadaver afterward. For HET, an 11-mm trocar was inserted in the 2nd intercostal space in the left anterior axillary line. A 0° 10-mm thoracoscope with a 5-mm working channel was introduced. Transesophageal access was created through a submucosal tunnel using a flexible gastroscope with a single working channel introduced through the mouth. Using both flexible (gastroscope) and rigid (thoracoscope) instruments, the mediastinum was opened; the thymus was dissected, and the vessels were ligated using electrocautery alone. RESULTS: Submucosal tunnel creation and esophagotomy were performed safely without incidents in all animals. Complete thymectomy was achieved in all experiments. All animals in the survival group lived for 14 days. Thoracoscopic and postmortem examination revealed pleural adhesions on site of the surgical procedure with no signs of infection. Histological analysis of the proximal third of the esophagus revealed complete cicatrization of both mucosal defect and myotomy site. In the human cadaver, we were able to replicate all the procedure even though we were not able to identify the thymus. CONCLUSIONS: Hybrid endoscopic thymectomy is feasible and reliable. HET could be regarded as a possible alternative to classic thoracoscopic approach for patients requiring thymectomy.This project was funded by the FCT Grants project PTDC/SAU-OSM/105578/2008
    • …
    corecore