19,386 research outputs found

    A hierarchy of linguistic predictions during natural language comprehension

    Get PDF
    Understanding spoken language requires transforming ambiguous acoustic streams into a hierarchy of representations, from phonemes to meaning. It has been suggested that the brain uses prediction to guide the interpretation of incoming input. However, the role of prediction in language processing remains disputed, with disagreement about both the ubiquity and representational nature of predictions. Here, we address both issues by analyzing brain recordings of participants listening to audiobooks, and using a deep neural network (GPT-2) to precisely quantify contextual predictions. First, we establish that brain responses to words are modulated by ubiquitous predictions. Next, we disentangle model-based predictions into distinct dimensions, revealing dissociable neural signatures of predictions about syntactic category (parts of speech), phonemes, and semantics. Finally, we show that high-level (word) predictions inform low-level (phoneme) predictions, supporting hierarchical predictive processing. Together, these results underscore the ubiquity of prediction in language processing, showing that the brain spontaneously predicts upcoming language at multiple levels of abstraction

    IF impedance and mixer gain of NbN hot electron bolometers

    Get PDF
    The intermediate frequency (IF) characteristics, the frequency dependent IF impedance, and the mixer conversion gain of a small area hot electron bolometer (HEB) have been measured and modeled. The device used is a twin slot antenna coupled NbN HEB mixer with a bridge area of 1×0.15 ”m^2, and a critical temperature of 8.3 K. In the experiment the local oscillator frequency was 1.300 THz, and the (IF) 0.05–10 GHz. We find that the measured data can be described in a self-consistent manner with a thin film model presented by Nebosis et al. [Proceedings of the Seventh International Symposium on Space Terahertz Technology, Charlottesville, VA, 1996 (unpublished), pp. 601–613], that is based on the two temperature electron-phonon heat balance equations of Perrin-Vanneste [J. Phys. (Paris) 48, 1311 (1987)]. From these results the thermal time constant, governing the gain bandwidth of HEB mixers, is observed to be a function of the electron-phonon scattering time, phonon escape time, and the electron temperature. From the developed theory the maximum predicted gain bandwidth for a NbN HEB is found to be 5.5–6 GHz. In contrast, the gain bandwidth of the device under discussion was measured to be ~2.3 GHz which, consistent with the outlined theory, is attributed to a somewhat low critical temperature and nonoptimal film thickness (6 nm)

    Manipulating word awareness dissociates feed-forward from feedback models of language-perception interactions

    Get PDF
    Previous studies suggest that linguistic material can modulate visual perception, but it is unclear at which level of processing these interactions occur. Here we aim to dissociate between two competing models of language–perception interactions: a feed-forward and a feedback model. We capitalized on the fact that the models make different predictions on the role of feedback. We presented unmasked (aware) or masked (unaware) words implying motion (e.g. “rise,” “fall”), directly preceding an upward or downward visual motion stimulus. Crucially, masking leaves intact feed-forward information processing from low- to high-level regions, whereas it abolishes subsequent feedback. Under this condition, participants remained faster and more accurate when the direction implied by the motion word was congruent with the direction of the visual motion stimulus. This suggests that language–perception interactions are driven by the feed-forward convergence of linguistic and perceptual information at higher-level conceptual and decision stages

    The High Frequency Instrument of Planck: Requirements and Design

    Get PDF
    The Planck satellite is a project of the European Space Agency based on a wide international collaboration, including United States and Canadian laboratories. It is dedicated to the measurement of the anisotropy of the Cosmic Microwave Background (CMB) with unprecedented sensitivity and angular resolution. The detectors of its High frequency Instrument (HFI) are bolometers cooled down to 100 mK. Their sensitivity will be limited by the photon noise of the CMB itself at low frequencies, and of the instrument background at high frequencies. The requirements on the measurement chain are directly related to the strategy of observation used for the satellite. Due to the scanning on the sky, time features of the measurement chain are directly transformed into angular features in the sky maps. This impacts the bolometer design as well as other elements: For example, the cooling system must present outstanding temperature stability, and the amplification chain must show, down to very low frequencies, a flat noise spectrum

    Towards T1-limited magnetic resonance imaging using Rabi beats

    Full text link
    Two proof-of-principle experiments towards T1-limited magnetic resonance imaging with NV centers in diamond are demonstrated. First, a large number of Rabi oscillations is measured and it is demonstrated that the hyperfine interaction due to the NV's 14N can be extracted from the beating oscillations. Second, the Rabi beats under V-type microwave excitation of the three hyperfine manifolds is studied experimentally and described theoretically.Comment: 6 pages, 8 figure

    Use of High Sensitivity Bolometers for Astronomy: Planck High Frequency Instrument

    Get PDF
    The Planck satellite is dedicated to the measurement of the anisotropy of the Cosmic Microwave Background (CMB) with unprecedented sensitivity and angular resolution. It is a project of the European Space Agency based on a wide international collaboration, including United States and Canadian laboratories. The detectors of its High Frequency Instrument (HFI) are bolometers cooled down to 100 mK. Their sensitivity will be limited by the photon noise of the CMB itself at low frequencies, and of the instrument background at high frequencies. The requirements on the measurement chain are directly related to the strategy of observation used for the satellite. This impacts the bolometer design as well as other elements: The cooling system must present outstanding temperature stability, and the amplification chain must show a flat noise spectrum down to very low frequencies

    HCl and ClO in activated Arctic air; first retrieved vertical profiles from TELIS submillimetre limb spectra

    Get PDF
    The first profile retrieval results of the Terahertz and submillimeter Limb Sounder (TELIS) balloon instrument are presented. The spectra are recorded during a 13-h balloon flight on 24 January 2010 from Kiruna, Sweden. The TELIS instrument was mounted on the MIPAS-B2 gondola and shared this platform with the Michelson Interferometer for Passive Atmospheric Sounding (MIPAS) and the mini- Differential Optical Absorption Spectroscopy (mini-DOAS) instruments. The flight took place within the Arctic vortex at an altitude of ≈34 km in chlorine activated air, and both active (ClO) and inactive chlorine (HCl) were measured over an altitude range of respectively ≈16–32 km and ≈10– 32 km. In this altitude range, the increase of ClO concentration levels during sunrise has been recorded with a temporal resolution of one minute. During the daytime equilibrium, a maximum ClO level of 2.1±0.3 ppbv has been observed at an altitude of 23.5 km. This equilibrium profile is validated against the ClO profile by the satellite instrument Microwave Limb Sounder (MLS) aboard EOS Aura. HCl profiles have been determined from two different isotopes – H35Cl and H37Cl – and are also validated againstMLS. The precision of all profiles is well below 0.01 ppbv and the overall accuracy is therefore governed by systematic effects. The total uncertainty of these effects is estimated to be maximal 0.3 ppbv for ClO around its peak value at 23.5 km during the daytime equilibrium, and for HCl it ranges from 0.05 to 0.4 ppbv, depending on altitude. In both cases the main uncertainty stems from a largely unknown non-linear response in the detector

    Qualidade do leite armazenado em tanques coletivos.

    Get PDF
    Importùncia da refrigeração do leite ; Tanques coletivos; Pesquisa sobre a qualidade do leite de tanques coletivos; Uma segunda pesquisa: maio de 2007 a junho de 2008.bitstream/item/65295/1/CT-99-Qualid-leite-armaz-tanq-coletivos.pd
    • 

    corecore