96 research outputs found

    Performance of automatic image segmentation algorithms for calculating total lesion glycolysis for early response monitoring in non-small cell lung cancer patients during concomitant chemoradiotherapy.

    Get PDF
    Background and purpose This study evaluated the use of total lesion glycolysis (TLG) determined by different automatic segmentation algorithms, for early response monitoring in non-small cell lung cancer (NSCLC) patients during concomitant chemoradiotherapy.Materials and methods Twenty-seven patients with locally advanced NSCLC treated with concomitant chemoradiotherapy underwent (18)F-fluorodeoxyglucose (FDG) PET/CT imaging before and in the second week of treatment. Segmentation of the primary tumours and lymph nodes was performed using fixed threshold segmentation at (i) 40% SUVmax (T40), (ii) 50% SUVmax (T50), (iii) relative-threshold-level (RTL), (iv) signal-to-background ratio (SBR), and (v) fuzzy locally adaptive Bayesian (FLAB) segmentation. Association of primary tumour TLG (TLGT), lymph node TLG (TLGLN), summed TLG (TLGS=TLGT+TLGLN), and relative TLG decrease (ΔTLG) with overall-survival (OS) and progression-free survival (PFS) was determined using univariate Cox regression models.Results Pretreatment TLGT was predictive for PFS and OS, irrespective of the segmentation method used. Inclusion of TLGLN improved disease and early response assessment, with pretreatment TLGS more strongly associated with PFS and OS than TLGT for all segmentation algorithms. This was also the case for ΔTLGS, which was significantly associated with PFS and OS, with the exception of RTL and T40.Conclusions ΔTLGS was significantly associated with PFS and OS, except for RTL and T40. Inclusion of TLGLN improves early treatment response monitoring during concomitant chemoradiotherapy with FDG-PET

    A comparison of the diagnostic value of MRI and <sup>18</sup>F-FDG-PET/CT in suspected spondylodiscitis.

    Get PDF
    Purpose The purpose of this study was to evaluate the diagnostic value of 18F-fluorodeoxyglucose (FDG) positron emission tomography and computed tomography (PET/CT scan) and magnetic resonance imaging (MRI) in diagnosing spondylodiscitis and its complications, such as epidural and paraspinal abscesses.Methods From January 2006 to August 2013 patients with a clinical suspicion of spondylodiscitis, with an infection, or with fever of unknown origin were retrospectively included if 18F-FDG-PET/CT and MRI of the spine were performed within a 2-week time span. Imaging results were compared to the final clinical diagnosis and follow-up data were collected.Results Sixty-eight patients were included of whom 49 patients were diagnosed with spondylodiscitis. MRI showed an overall sensitivity of 67 % and specificity of 84 %. Diagnostic accuracy was 58 %, when MRI was performed within 2 weeks after the start of symptoms and improved to 82 %, when performed more than 2 weeks after onset of symptoms. 18F-FDG-PET/CT showed a sensitivity of 96 % and a specificity of 95 %, with no relation to the interval between the scan and the start of symptoms.Conclusions As compared to MRI, 18F-FDG-PET/CT has superior diagnostic value for detecting early spondylodiscitis. After 2 weeks both techniques perform similarly

    Cell-based tracers as Trojan horses for image-guided surgery

    Get PDF
    Surgeons rely almost completely on their own vision and palpation to recognize affected tissues during surgery. Consequently, they are often unable to distinguish between different cells and tissue types. This makes accurate and complete resection cumbersome. Targeted image-guided surgery (IGS) provides a solution by enabling real-time tissue recognition. Most current targeting agents (tracers) consist of antibodies or peptides equipped with a radiolabel for Positron Emission Tomography (PET) and Single Photon Emission Computed Tomography (SPECT), magnetic resonance imaging (MRI) labels, or a near-infrared fluorescent (NIRF) dye. These tracers are preoperatively administered to patients, home in on targeted cells or tissues, and are visualized in the operating room via dedicated imaging systems. Instead of using these ‘passive’ tracers, there are other, more ‘active’ approaches of probe delivery conceivable by using living cells (macrophages/monocytes, neutrophils, T cells, mesenchymal stromal cells), cell(-derived) fragments (platelets, extracellular vesicles (exosomes)), and microorganisms (bacteria, viruses) or, alternatively, ‘humanized’ nanoparticles. Compared with current tracers, these active contrast agents might be more efficient for the specific targeting of tumors or other pathological tissues (e.g., atherosclerotic plaques). This review provides an overview of the arsenal of possibilities applicable for the concept of cell-based tracers for IGS

    Impact of the COVID-19 crisis on imaging in oncological trials

    Get PDF
    The unprecedented demand for hospital services during the SARS-CoV-2 (COVID-19) pandemic has dramatically reduced the capability for dealing with non-acute health needs, including cancer care [1, 2]. To alleviate burden on health care systems, including imaging and laboratory services, curtailment of non-COVID-19-related research activity has been necessary [3]. Measures that reduce hospital visits have been adopted to limit risk of infection and death, which is critical in a cancer population whose age and immunocompromised status increases their risk [4]. Imaging, however, requires hospital visits and close contact with staff and equipment; both are sources of disease transmission. Equipment used to image COVID-19 cases may retain virus on its surface for days [5, 6] unless disinfected. The need for social distancing and for disinfecting equipment substantially slows imaging workflow and reduces throughput. This article discusses the specific impact of pandemics such as SARS-CoV-2 on imaging in oncological trials

    <sup>18</sup>F-FDG PET/CT Optimizes Treatment in <i>Staphylococcus Aureus</i> Bacteremia and Is Associated with Reduced Mortality.

    Get PDF
    Metastatic infection is an important complication of Staphylococcus aureus bacteremia (SAB). Early diagnosis of metastatic infection is crucial, because specific treatment is required. However, metastatic infection can be asymptomatic and difficult to detect. In this study, we investigated the role of 18 F-FDG PET/CT in patients with SAB for detection of metastatic infection and its consequences for treatment and outcome. Methods: All patients with SAB at Radboud University Medical Center were included between January 2013 and April 2016. Clinical data and results of 18 F-FDG PET/CT and other imaging techniques, including echocardiography, were collected. Primary outcomes were newly diagnosed metastatic infection by 18 F-FDG PET/CT, subsequent treatment modifications, and patient outcome. Results: A total of 184 patients were included, and 18 F-FDG PET/CT was performed in 105 patients, of whom 99 had a high-risk bacteremia. 18 F-FDG PET/CT detected metastatic infectious foci in 73.7% of these high-risk patients. In 71.2% of patients with metastatic infection, no signs and symptoms suggesting metastatic complications were present before 18 F-FDG PET/CT was performed. 18 F-FDG PET/CT led to a total of 104 treatment modifications in 74 patients. Three-month mortality was higher in high-risk bacteremia patients without 18 F-FDG PET/CT performed than in those in whom 18 F-FDG PET/CT was performed (32.7% vs. 12.4%, P = 0.003). In multivariate analysis, 18 F-FDG PET/CT was the only factor independently associated with reduced mortality ( P = 0.005; odds ratio, 0.204; 95% confidence interval, 0.066-0.624). A higher comorbidity score was independently associated with increased mortality ( P = 0.003; odds ratio, 1.254; 95% confidence interval, 1.078-1.457). Conclusion: 18 F-FDG PET/CT is a valuable technique for early detection of metastatic infectious foci, often leading to treatment modification. Performing 18 F-FDG PET/CT is associated with significantly reduced 3-mo mortality

    Standardised lesion segmentation for imaging biomarker quantitation: a consensus recommendation from ESR and EORTC.

    Get PDF
    BACKGROUND: Lesion/tissue segmentation on digital medical images enables biomarker extraction, image-guided therapy delivery, treatment response measurement, and training/validation for developing artificial intelligence algorithms and workflows. To ensure data reproducibility, criteria for standardised segmentation are critical but currently unavailable. METHODS: A modified Delphi process initiated by the European Imaging Biomarker Alliance (EIBALL) of the European Society of Radiology (ESR) and the European Organisation for Research and Treatment of Cancer (EORTC) Imaging Group was undertaken. Three multidisciplinary task forces addressed modality and image acquisition, segmentation methodology itself, and standards and logistics. Devised survey questions were fed via a facilitator to expert participants. The 58 respondents to Round 1 were invited to participate in Rounds 2-4. Subsequent rounds were informed by responses of previous rounds. RESULTS/CONCLUSIONS: Items with ≥ 75% consensus are considered a recommendation. These include system performance certification, thresholds for image signal-to-noise, contrast-to-noise and tumour-to-background ratios, spatial resolution, and artefact levels. Direct, iterative, and machine or deep learning reconstruction methods, use of a mixture of CE marked and verified research tools were agreed and use of specified reference standards and validation processes considered essential. Operator training and refreshment were considered mandatory for clinical trials and clinical research. Items with a 60-74% agreement require reporting (site-specific accreditation for clinical research, minimal pixel number within lesion segmented, use of post-reconstruction algorithms, operator training refreshment for clinical practice). Items with ≤ 60% agreement are outside current recommendations for segmentation (frequency of system performance tests, use of only CE-marked tools, board certification of operators, frequency of operator refresher training). Recommendations by anatomical area are also specified

    Fully three-dimensional sound speed-corrected multi-wavelength photoacoustic breast tomography

    Full text link
    Photoacoustic tomography is a contrast agent-free imaging technique capable of visualizing blood vessels and tumor-associated vascularization in breast tissue. While sophisticated breast imaging systems have been recently developed, there is yet much to be gained in imaging depth, image quality and tissue characterization capability before clinical translation is possible. In response, we have developed a hybrid photoacoustic and ultrasound-transmission tomographic system PAM3. The photoacoustic component has for the first time three-dimensional multi-wavelength imaging capability, and implements substantial technical advancements in critical hardware and software sub-systems. The ultrasound component enables for the first time, a three-dimensional sound speed map of the breast to be incorporated in photoacoustic reconstruction to correct for inhomogeneities, enabling accurate target recovery. The results demonstrate the deepest photoacoustic breast imaging to date namely 48 mm, with a more uniform field of view than hitherto, and an isotropic spatial resolution that rivals that of Magnetic Resonance Imaging. The in vivo performance achieved, and the diagnostic value of interrogating angiogenesis-driven optical contrast as well as tumor mass sound speed contrast, gives confidence in the system's clinical potential.Comment: 33 pages Main Body, 9 pages Supplementary Materia

    <sup>89</sup>Zr-Trastuzumab PET/CT Imaging of HER2-Positive Breast Cancer for Predicting Pathological Complete Response after Neoadjuvant Systemic Therapy:A Feasibility Study

    Get PDF
    Background: Approximately 20% of invasive ductal breast malignancies are human epidermal growth factor receptor 2 (HER2)-positive. These patients receive neoadjuvant systemic therapy (NAT) including HER2-targeting therapies. Up to 65% of patients achieve a pathological complete response (pCR). These patients might not have needed surgery. However, accurate preoperative identification of a pCR remains challenging. A radiologic complete response (rCR) on MRI corresponds to a pCR in only 73% of patients. The current feasibility study investigates if HER2-targeted PET/CT-imaging using Zirconium-89 (89Zr)-radiolabeled trastuzumab can be used for more accurate NAT response evaluation. Methods: HER2-positive breast cancer patients scheduled to undergo NAT and subsequent surgery received a 89Zr-trastuzumab PET/CT both before (PET/CT-1) and after (PET/CT-2) NAT. Qualitative and quantitative response evaluation was performed. Results: Six patients were enrolled. All primary tumors could be identified on PET/CT-1. Four patients had a pCR and two a pathological partial response (pPR) in the primary tumor. Qualitative assessment of PET/CT resulted in an accuracy of 66.7%, compared to 83.3% of the standard-of-care MRI. Quantitative assessment showed a difference between the SUVR on PET/CT-1 and PET/CT-2 (ΔSUVR) in patients with a pPR and pCR of −48% and −90% (p = 0.133), respectively. The difference in tumor-to-blood ratio on PET/CT-1 and PET/CT-2 (ΔTBR) in patients with pPR and pCR was −79% and −94% (p = 0.133), respectively. Three patients had metastatic lymph nodes at diagnosis that were all identified on PET/CT-1. All three patients achieved a nodal pCR. Qualitative assessment of the lymph nodes with PET/CT resulted in an accuracy of 66.7%, compared to 50% of the MRI. Conclusions: NAT response evaluation using 89Zr-trastuzumab PET/CT is feasible. In the current study, qualitative assessment of the PET/CT images is not superior to standard-of-care MRI. Our results suggest that quantitative assessment of 89Zr-trastuzumab PET/CT has potential for a more accurate response evaluation of the primary tumor after NAT in HER2-positive breast cancer.</p

    Imaging standardisation in metastatic colorectal cancer: A joint EORTC-ESOI-ESGAR expert consensus recommendation

    Get PDF
    Background: Treatment monitoring in metastatic colorectal cancer (mCRC) relies on imaging to evaluate the tumour burden. Response Evaluation Criteria in Solid Tumors provide a framework on reporting and interpretation of imaging findings yet offer no guidance on a standardised imaging protocol tailored to patients with mCRC. Imaging protocol hetero-geneity remains a challenge for the reproducibility of conventional imaging end-points and is an obstacle for research on novel imaging end-points.Patients and methods: Acknowledging the recently highlighted potential of radiomics and arti-ficial intelligence tools as decision support for patient care in mCRC, a multidisciplinary, international and expert panel of imaging specialists was formed to find consensus on mCRC imaging protocols using the Delphi method.Results: Under the guidance of the European Organisation for Research and Treatment of Cancer (EORTC) Imaging and Gastrointestinal Tract Cancer Groups, the European Society of Oncologic Imaging (ESOI) and the European Society of Gastrointestinal and Abdominal Radiology (ESGAR), the EORTC-ESOI-ESGAR core imaging protocol was identified.Conclusion: This consensus protocol attempts to promote standardisation and to diminish variations in patient preparation, scan acquisition and scan reconstruction. We anticipate that this standardisation will increase reproducibility of radiomics and artificial intelligence studies and serve as a catalyst for future research on imaging end-points. For ongoing and future mCRC trials, we encourage principal investigators to support the dissemination of these im-aging standards across recruiting centres. (c) 2022 The Author(s). Published by Elsevier Ltd. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/)

    Twenty years on: RECIST as a biomarker of response in solid tumours. An EORTC Imaging Group – ESOI joint paper

    Get PDF
    Response evaluation criteria in solid tumours (RECIST) v1.1 are currently the reference standard for evaluating efficacy of therapies in patients with solid tumours who are included in clinical trials, and they are widely used and accepted by regulatory agencies. This expert statement discusses the principles underlying RECIST, as well as their reproducibility and limitations. While the RECIST framework may not be perfect, the scientific bases for the anticancer drugs that have been approved using a RECIST-based surrogate endpoint remain valid. Importantly, changes in measurement have to meet thresholds defined by RECIST for reponse classification within thus partly circumventing the problems of measurement variability. The RECIST framework also applies to clinical patients in individual settings even though the relationship between tumour size changes and outcome from cohort studies is not necessarily translatable to individual cases. As reproducibility of RECIST measurements is impacted by reader experience, choice of target lesions and detection/interpretation of new lesions, it can result in patients changing response categories when measurements are near threshold values or if new lesions are missed or incorrectly interpreted. There are several situations where RECIST will fail to evaluate treatment-induced changes correctly; knowledge and understanding of these is crucial for correct interpretation. Also, some patterns of response/progression cannot be correctly documented by RECIST, particularly in relation to organ-site (e.g. bone without associated soft-tissue lesion) and treatment type (e.g. focal therapies). These require specialist reader experience and communication with oncologists to determine the actual impact of the therapy and best evaluation strategy. In such situations, alternative imaging markers for tumour response may be used but the sources of variability of individual imaging techniques need to be known and accounted for. Communication between imaging experts and oncologists regarding the level of confidence in a biomarker is essential for the correct interpretation of a biomarker and its application to clinical decision-making. Though measurement automation is desirable and potentially reduces the variability of results, associated technical difficulties must be overcome, and human adjudications may be required
    • …
    corecore