217 research outputs found

    3-4.5 μm continuously tunable single mode VECSEL

    Get PDF
    We present continuously tunable Vertical External Cavity Surface Emitting Lasers (VECSEL) in the mid-infrared. The structure based on IV-VI semiconductors is epitaxially grown on a Si-substrates. The VECSEL emit one single mode, which is mode hop-free tunable over 50-100nm around the center wavelength. In this work, two different devices are presented, emitting at 3.4μm and 3.9μm, respectively. The lasers operate near room temperature with thermoelectric stabilization. They are optically pumped, yielding an output power >10mWp. The axial symmetric emission beam has a half divergence angle of <3.3

    5-μm vertical external-cavity surface-emitting laser (VECSEL) forspectroscopic applications

    Get PDF
    Mid-IR tunable VECSELs (Vertical External-Cavity Surface-Emitting Lasers) emitting at 4-7 μm wavelengths and suitable for spectroscopic sensing applications are described. They are realized with lead-chalcogenide (IV-VI) narrow band gap materials. The active part, a single 0.6-2-μm thick PbTe or PbSe gain layer, is grown onto an epitaxial Bragg mirror consisting of two or three Pb1−y EuyTe/BaF2 quarter-wavelength layer pairs. All layers are deposited by MBE in a single run employing a BaF2 or Si substrate, no further processing is needed. The cavity is completed with an external curved top mirror, which is again realized with an epitaxial Bragg structure. Pumping is performed optically with a 1.5-μm laser. Maximum output power for pulsed operation is currently up to >1 Wp at −173°C and >10 mW at 10°C. In continuous wave (CW) operation, 18 mW at 100 K are reached. Still higher operating temperatures and/or powers are expected with better heat-removal structures and better designs employing QW (Quantum-Wells). Advantages of mid-IR VECSELs compared to edge-emitting lasers are their very good beam quality (circular beam with 15 μm are accessible with Pb1−y XyZ (X=Sr, Eu, Sn, Z=Se, Te) and/or including Q

    Maternal Platelets And The Thrombin Receptor, Par4, Disrupt Placental Morphogenesis And Cause Fetal Loss In Factor V Leiden Mice

    Full text link
    Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/106057/1/jth02468.pd

    Epitaxial Lead Chalcogenides on Si for Mid-IR Detectors and Emitters Including Cavities

    Get PDF
    Lead chalcogenide (IV-VI narrow-gap semiconductor) layers on Si or BaF2(111) substrates are employed to realize two mid-infrared optoelectronic devices for the first time. A tunable resonant cavity enhanced detector is realized by employing a movable mirror. Tuning is across the 4μm to 5.5μm wavelength range, and linewidth is <0.1μm. Due to the thin (0.3μm) PbTe photodiode inside the cavity, a higher sensitivity at higher operating temperatures was achieved as compared to conventional thick photodiodes. The second device is an optically pumped vertical external-cavity surface-emitting laser with PbTe-based gain layers. It emits at ∼5μm wavelength and with output power up to 50mW pulsed, or 3mW continuous wave at 100

    A review of the use of terrestrial laser scanning application for change detection and deformation monitoring of structures

    Get PDF
    Change detection and deformation monitoring is an active area of research within the field of engineering surveying as well as overlapping areas such as structural and civil engineering. The application of Terrestrial Laser Scanning (TLS) techniques for change detection and deformation monitoring of concrete structures has increased over the years as illustrated in the past studies. This paper presents a review of literature on TLS application in the monitoring of structures and discusses registration and georeferencing of TLS point cloud data as a critical issue in the process chain of accurate deformation analysis. Past TLS research work has shown some trends in addressing issues such as accurate registration and georeferencing of the scans and the need of a stable reference frame, TLS error modelling and reduction, point cloud processing techniques for deformation analysis, scanner calibration issues and assessing the potential of TLS in detecting sub-centimetre and millimetre deformations. However, several issues are still open to investigation as far as TLS is concerned in change detection and deformation monitoring studies such as rigorous and efficient workflow methodology of point cloud processing for change detection and deformation analysis, incorporation of measurement geometry in deformation measurements of high-rise structures, design of data acquisition and quality assessment for precise measurements and modelling the environmental effects on the performance of laser scanning. Even though some studies have attempted to address these issues, some gaps exist as information is still limited. Some methods reviewed in the case studies have been applied in landslide monitoring and they seem promising to be applied in engineering surveying to monitor structures. Hence the proposal of a three-stage process model for deformation analysis is presented. Furthermore, with technological advancements new TLS instruments with better accuracy are being developed necessitating more research for precise measurements in the monitoring of structures

    Introduction of Ophiobolus graminis into new polders and its decline

    Full text link

    Obeticholic acid for the treatment of non-alcoholic steatohepatitis: interim analysis from a multicentre, randomised, placebo-controlled phase 3 trial

    Get PDF
    BACKGROUND Non-alcoholic steatohepatitis (NASH) is a common type of chronic liver disease that can lead to cirrhosis. Obeticholic acid, a farnesoid X receptor agonist, has been shown to improve the histological features of NASH. Here we report results from a planned interim analysis of an ongoing, phase 3 study of obeticholic acid for NASH. METHODS In this multicentre, randomised, double-blind, placebo-controlled study, adult patients with definite NASH, non-alcoholic fatty liver disease (NAFLD) activity score of at least 4, and fibrosis stages F2-F3, or F1 with at least one accompanying comorbidity, were randomly assigned using an interactive web response system in a 1:1:1 ratio to receive oral placebo, obeticholic acid 10 mg, or obeticholic acid 25 mg daily. Patients were excluded if cirrhosis, other chronic liver disease, elevated alcohol consumption, or confounding conditions were present. The primary endpoints for the month-18 interim analysis were fibrosis improvement (≥1 stage) with no worsening of NASH, or NASH resolution with no worsening of fibrosis, with the study considered successful if either primary endpoint was met. Primary analyses were done by intention to treat, in patients with fibrosis stage F2-F3 who received at least one dose of treatment and reached, or would have reached, the month 18 visit by the prespecified interim analysis cutoff date. The study also evaluated other histological and biochemical markers of NASH and fibrosis, and safety. This study is ongoing, and registered with ClinicalTrials.gov, NCT02548351, and EudraCT, 20150-025601-6. FINDINGS Between Dec 9, 2015, and Oct 26, 2018, 1968 patients with stage F1-F3 fibrosis were enrolled and received at least one dose of study treatment; 931 patients with stage F2-F3 fibrosis were included in the primary analysis (311 in the placebo group, 312 in the obeticholic acid 10 mg group, and 308 in the obeticholic acid 25 mg group). The fibrosis improvement endpoint was achieved by 37 (12%) patients in the placebo group, 55 (18%) in the obeticholic acid 10 mg group (p=0·045), and 71 (23%) in the obeticholic acid 25 mg group (p=0·0002). The NASH resolution endpoint was not met (25 [8%] patients in the placebo group, 35 [11%] in the obeticholic acid 10 mg group [p=0·18], and 36 [12%] in the obeticholic acid 25 mg group [p=0·13]). In the safety population (1968 patients with fibrosis stages F1-F3), the most common adverse event was pruritus (123 [19%] in the placebo group, 183 [28%] in the obeticholic acid 10 mg group, and 336 [51%] in the obeticholic acid 25 mg group); incidence was generally mild to moderate in severity. The overall safety profile was similar to that in previous studies, and incidence of serious adverse events was similar across treatment groups (75 [11%] patients in the placebo group, 72 [11%] in the obeticholic acid 10 mg group, and 93 [14%] in the obeticholic acid 25 mg group). INTERPRETATION Obeticholic acid 25 mg significantly improved fibrosis and key components of NASH disease activity among patients with NASH. The results from this planned interim analysis show clinically significant histological improvement that is reasonably likely to predict clinical benefit. This study is ongoing to assess clinical outcomes. FUNDING Intercept Pharmaceuticals
    • …
    corecore