710 research outputs found

    Do parity doublets in the baryon spectrum reflect restoration of chiral symmetry?

    Get PDF
    We discuss the mass spectrum of highly-excited nucleon and Δ∗\Delta^* resonances. The spectrum exhibits parity doublets, pairs of resonances of identical total angular momentum J but of opposite parity. It has been proposed that the parity doublets evidence restoration of chiral symmetry at large baryon excitation energies. We compare this conjecture with the possibility that high-mass states are organized into (L,S)(L,S)-multiplets with defined intrinsic quark spins and orbital angular momenta. Indeed, the latter interpretation results in a better description of the data. There is however a small and statisticially not very significant trend of the data which might indicate that chiral symmetry is not yet restored but does influence the masses of highly excited states.Comment: 10 pages, 1 fi

    Development of a Certified Reference Material for myeloperoxidase-anti-neutrophil cytoplasmic autoantibodies (MPO-ANCA).

    Get PDF
    A serum Certified Reference Material (CRM) for supporting reliable autoimmune diagnostics was recently released by the Institute for Reference Materials and Measurements (IRMM) of the Joint Research Centre of the European Commission. It was produced in collaboration with a Working Group on the Harmonisation of Autoimmune Tests of the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC WG-HAT). This material is aimed at facilitating the standardisation of measurements of anti-myeloperoxidase immunoglobulin G antibodies. The CRM could be used as a common calibrant by clinicians and manufacturers thereby significantly improving the comparability of results from commercial immunoassays used for IgG anti-MPO measurements. This paper provides information on the new CRM and its intended use

    Standardization of autoimmune testing - is it feasible?

    Get PDF
    Correct measurement of autoantibodies is essential for the diagnosis of autoimmune diseases. However, due to the variability of autoantibody results and the heterogeneity of testing, wrong diagnosis is a reality. For this and more reasons, harmonization of testing is of the outmost importance. In this review we have summarized the factors contributing to this variability. The ways with which the working group on harmonization of autoantibody testing of the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) has been trying to tackle the issue with the production and correct use of certified reference materials (CRMs), is discussed. Finally the advantages and the limitations of the use of CRMs are presented

    Benchmarking nuclear models for Gamow-Teller response

    Get PDF
    A comparative study of the nuclear Gamow-Teller response (GTR) within conceptually different state-of-the-art approaches is presented. Three nuclear microscopic models are considered: (i) the recently developed charge-exchange relativistic time blocking approximation (RTBA) based on the covariant density functional theory, (ii) the shell model (SM) with an extended "jj77" model space and (iii) the non-relativistic quasiparticle random-phase approximation (QRPA) with a Brueckner G-matrix effective interaction. We study the physics cases where two or all three of these models can be applied. The Gamow-Teller response functions are calculated for 208-Pb, 132-Sn and 78-Ni within both RTBA and QRPA. The strengths obtained for 208-Pb are compared to data that enables a firm model benchmarking. For the nucleus 132-Sn, also SM calculations are performed within the model space truncated at the level of a particle-hole (ph) coupled to vibration configurations. This allows a consistent comparison to the RTBA where ph+phonon coupling is responsible for the spreading width and considerable quenching of the GTR. Differences between the models and perspectives of their future developments are discussed.Comment: 9 pages, 2 figures, 1 table; to be published in Phys. Lett.

    Functional Interplay of Type-2 Corticotrophin Releasing Factor and Dopamine Receptors in the Basolateral Amygdala-Medial Prefrontal Cortex Circuitry

    Get PDF
    Background: Basolateral amygdala (BLA) excitatory projections to medial prefrontal cortex (PFC) play a key role controlling stress behavior, pain, and fear. Indeed, stressful events block synaptic plasticity at the BLA-PFC circuit. The stress responses involve the action of corticotrophin releasing factor (CRF) through type 1 and type 2 CRF receptors (CRF1 and CRF2). Interestingly, it has been described that dopamine receptor 1 (D1R) and CRF peptide have a modulatory role of BLA-PFC transmission. However, the participation of CRF1 and CRF2 receptors in BLA-PFC synaptic transmission still is unclear. Methods: We used in vivo microdialysis to determine dopamine and glutamate (GLU) extracellular levels in PFC after BLA stimulation. Immunofluorescence anatomical studies in rat PFC synaptosomes devoid of postsynaptic elements were performed to determine the presence of D1R and CRF2 receptors in synaptical nerve endings. Results: Here, we provide direct evidence of the opposite role that CRF receptors exert over dopamine extracellular levels in the PFC. We also show that D1R colocalizes with CRF2 receptors in PFC nerve terminals. Intra-PFC infusion of antisauvagine-30, a CRF2 receptor antagonist, increased PFC GLU extracellular levels induced by BLA activation. Interestingly, the increase in GLU release observed in the presence of antisauvagine-30 was significantly reduced by incubation with SCH23390, a D1R antagonist. Conclusion: PFC CRF2 receptor unmasks D1R effect over glutamatergic transmission of the BLA-PFC circuit. Overall, CRF2 receptor emerges as a new modulator of BLA to PFC glutamatergic transmission, thus playing a potential role in emotional disorders. Keywords: CRF2 receptor; D1 receptor; dopaminergic transmission; glutamatergic transmission; prefrontal cortex

    The certification of anti-myeloperoxidase immunoglobulin G in human serum ERMÂź - DA476/IFCC

    Get PDF
    This report describes the production and certification of ERM-DA476/IFCC, a new serum protein reference material intended for the standardisation of measurements of anti-myeloperoxidase immunoglobulin G (anti-MPO IgG) antibodies. The material was produced according to ISO Guide 34:2009. The raw material used to prepare ERM-DA476/IFCC was a plasmapheresis material containing a high concentration of anti-MPO IgG. After a thorough commutability study lyophilised serum was selected as the format for the candidate reference material. Serum processing was performed based on the procedure used for the reference material ERM-DA470k/IFCC. The plasma was converted into serum which was then delipidated. After the addition of preservatives the processed serum was diluted with plasmapheresis solution containing albumin, prior to the transfer of 1 mL aliquots to glass vials. The serum was then lyophilised and the vials closed with rubber stoppers and screw caps under nitrogen atmosphere prior to storage at -70 °C. The between unit-homogeneity was quantified and stability during dispatch and storage were assessed in accordance with ISO Guide 35:2006. The material was characterised by an inter-laboratory comparison exercise performed by laboratories of demonstrated competence and with adherence to ISO/IEC 17025 , using a purified anti-MPO IgG preparation as calibrant. This was achieved using a value transfer protocol previously used in the characterisation of ERM-DA470k/IFCC. Technically invalid results were removed. However no other outliers were eliminated on statistical grounds only. Uncertainties of the certified values were calculated in accordance to the Guide to the Expression of Uncertainty in Measurement (GUM) and include uncertainties relating to possible lack of homogeneity, instability and characterisation. The material is intended for the calibration of methods and quality control. As any reference material, it can also be used for control charts or validation studies. The CRM is available in glass vials containing the lyophilised residue of 1 g serum. The minimum amount of reconstituted sample to be used is 10 ÎŒL. The CRM was accepted as European Reference Material (ERMÂź) after peer evaluation by the partners of the European Reference Materials consortium

    Photoproduction of Baryons Decaying into N pi and N eta

    Full text link
    A combined analysis of photoproduction data on \gamma p to \pi N, eta N was performed including the data on K Lambda and K Sigma. The data are interpreted in an isobar model with s--channel baryon resonances and pi, rho,(omega), K, and K^* exchange in the t--channel. Three baryon resonances have a substantial coupling to eta N, the well known N(1535)S_{11}, N(1720)P_{13}, and N(2070)D_{15}. The inclusion of data with open strangeness reveals the presence of further new resonances, N(1840)P_{11}, N(1875)D_{13} and N(2170)D_{13}.Comment: 13 pages, 14 figure
    • 

    corecore