29 research outputs found

    Humoral response to SARS-CoV-2 infection among liver transplant recipients

    Get PDF
    Objective Immunosuppressive agents are known to interfere with T and/or B lymphocytes, which are required to mount an adequate serologic response. Therefore, we aim to investigate the antibody response to SARS-CoV-2 in liver transplant (LT) recipients after COVID-19. Design Prospective multicentre case-control study, analysing antibodies against the nucleocapsid protein, spike (S) protein of SARS-CoV-2 and their neutralising activity in LT recipients with confirmed SARS-CoV-2 infection (COVID-19-LT) compared with immunocompetent patients (COVID-19-immunocompetent) and LT recipients without COVID-19 symptoms (non-COVID-19-LT). Results Overall, 35 LT recipients were included in the COVID-19-LT cohort. 35 and 70 subjects fulfilling the matching criteria were assigned to the COVID-19-immunocompetent and non-COVID-19-LT cohorts, respectively. We showed that LT recipients, despite immunosuppression and less symptoms, mounted a detectable antinucleocapsid antibody titre in 80% of the cases, although significantly lower compared with the COVID-19-immunocompetent cohort (3.73 vs 7.36 index level, p<0.001). When analysing anti-S antibody response, no difference in positivity rate was found between the COVID-19-LT and COVID-19-immunocompetent cohorts (97.1% vs 100%, p=0.314). Functional antibody testing showed neutralising activity in 82.9% of LT recipients (vs 100% in COVID-19-immunocompetent cohort, p=0.024). Conclusions Our findings suggest that the humoral response of LT recipients is only slightly lower than expected, compared with COVID-19 immunocompetent controls. Testing for anti-S antibodies alone can lead to an overestimation of the neutralising ability in LT recipients. Altogether, routine antibody testing against separate SARS-CoV-2 antigens and functional testing show that the far majority of LT patients are capable of mounting an adequate antibody response with neutralising ability.Cellular mechanisms in basic and clinical gastroenterology and hepatolog

    Highly-parallelized simulation of a pixelated LArTPC on a GPU

    Get PDF
    The rapid development of general-purpose computing on graphics processing units (GPGPU) is allowing the implementation of highly-parallelized Monte Carlo simulation chains for particle physics experiments. This technique is particularly suitable for the simulation of a pixelated charge readout for time projection chambers, given the large number of channels that this technology employs. Here we present the first implementation of a full microphysical simulator of a liquid argon time projection chamber (LArTPC) equipped with light readout and pixelated charge readout, developed for the DUNE Near Detector. The software is implemented with an end-to-end set of GPU-optimized algorithms. The algorithms have been written in Python and translated into CUDA kernels using Numba, a just-in-time compiler for a subset of Python and NumPy instructions. The GPU implementation achieves a speed up of four orders of magnitude compared with the equivalent CPU version. The simulation of the current induced on 10^3 pixels takes around 1 ms on the GPU, compared with approximately 10 s on the CPU. The results of the simulation are compared against data from a pixel-readout LArTPC prototype

    What every reader should know about studies using electronic health record data but may be afraid to ask

    No full text
    10.2196/22219Journal of Medical Internet Research233e2221

    Marrow versus peripheral blood for geno-identical allogeneic stem cell transplantation in acute myelocytic leukemia: Influence of dose and stem cell source shows better outcome with rich marrow

    No full text
    Several studies have compared bone marrow (BM) and peripheral blood (PB) as stem cell sources in patients receiving allografts, but the cell doses infused have not been considered, especially for BM. Using the ALWP/EBMT registry, we retrospectively studied 881 adult patients with acute myelocytic leukemia (AML), who received a non-T-depleted allogeneic BM (n = 515) or mobilized PB (n = 366) standard transplant, in first remission (CR1), from an HLA-identical sibling, over a 5-year period from January 1994. The BM cell dose ranged from 0.17 to 29 × 108/kg with a median of 2.7 × 108/kg. The PB cell dose ranged from 0.02 to 77 × 10 8/kg with a median of 9.3 × 108/kg. The median dose for patients receiving BM (2.7 × 108/kg) gave the greatest discrimination. In multivariate analyses, high-dose BM compared to PB was associated with lower transplant-related mortality (RR = 0.61; 95% CI, 0.39-0.98; P = .04), better leukemia-free survival (RR = 0.65; 95% CI, 0.46-0.91; P = .013), and better overall survival (RR = 0.64; 95% CI, 0.44-0. 92; P = .016). The present study in patients with AML receiving allografts in first remission indicates a better outcome with BM as compared to PB, when the dose of BM infused is rich. © 2003 by The American Society of Hematology

    Marrow versus peripheral blood for geno-identical allogeneic stem cell transplantation in acute myelocytic leukemia: Influence of dose and stem cell source shows better outcome with rich marrow

    No full text
    PubMed ID: 12829583Several studies have compared bone marrow (BM) and peripheral blood (PB) as stem cell sources in patients receiving allografts, but the cell doses infused have not been considered, especially for BM. Using the ALWP/EBMT registry, we retrospectively studied 881 adult patients with acute myelocytic leukemia (AML), who received a non-T-depleted allogeneic BM (n = 515) or mobilized PB (n = 366) standard transplant, in first remission (CR1), from an HLA-identical sibling, over a 5-year period from January 1994. The BM cell dose ranged from 0.17 to 29 × 10 8 /kg with a median of 2.7 × 10 8 /kg. The PB cell dose ranged from 0.02 to 77 × 10 8 /kg with a median of 9.3 × 10 8 /kg. The median dose for patients receiving BM (2.7 × 10 8 /kg) gave the greatest discrimination. In multivariate analyses, high-dose BM compared to PB was associated with lower transplant-related mortality (RR = 0.61; 95% CI, 0.39-0.98; P = .04), better leukemia-free survival (RR = 0.65; 95% CI, 0.46-0.91; P = .013), and better overall survival (RR = 0.64; 95% CI, 0.44-0. 92; P = .016). The present study in patients with AML receiving allografts in first remission indicates a better outcome with BM as compared to PB, when the dose of BM infused is rich. © 2003 by The American Society of Hematology

    Doping Liquid Argon with Xenon in ProtoDUNE Single-Phase: Effects on Scintillation Light

    No full text
    International audienceDoping of liquid argon TPCs (LArTPCs) with a small concentration of xenon is a technique for light-shifting and facilitates the detection of the liquid argon scintillation light. In this paper, we present the results of the first doping test ever performed in a kiloton-scale LArTPC. From February to May 2020, we carried out this special run in the single-phase DUNE Far Detector prototype (ProtoDUNE-SP) at CERN, featuring 770 t of total liquid argon mass with 410 t of fiducial mass. The goal of the run was to measure the light and charge response of the detector to the addition of xenon, up to a concentration of 18.8 ppm. The main purpose was to test the possibility for reduction of non-uniformities in light collection, caused by deployment of photon detectors only within the anode planes. Light collection was analysed as a function of the xenon concentration, by using the pre-existing photon detection system (PDS) of ProtoDUNE-SP and an additional smaller set-up installed specifically for this run. In this paper we first summarize our current understanding of the argon-xenon energy transfer process and the impact of the presence of nitrogen in argon with and without xenon dopant. We then describe the key elements of ProtoDUNE-SP and the injection method deployed. Two dedicated photon detectors were able to collect the light produced by xenon and the total light. The ratio of these components was measured to be about 0.65 as 18.8 ppm of xenon were injected. We performed studies of the collection efficiency as a function of the distance between tracks and light detectors, demonstrating enhanced uniformity of response for the anode-mounted PDS. We also show that xenon doping can substantially recover light losses due to contamination of the liquid argon by nitrogen
    corecore