1,599 research outputs found

    A Pixel Vertex Tracker for the TESLA Detector

    Get PDF
    In order to fully exploit the physics potential of a e+e- linear collider, such as TESLA, a Vertex Tracker providing high resolution track reconstruction is required. Hybrid Silicon pixel sensors are an attractive sensor technology option due to their read-out speed and radiation hardness, favoured in the high rate TESLA environment, but have been so far limited by the achievable single point space resolution. A novel layout of pixel detectors with interleaved cells to improve their spatial resolution is introduced and the results of the characterisation of a first set of test structures are discussed. In this note, a conceptual design of the TESLA Vertex Tracker, based on hybrid pixel sensors is presentedComment: 20 pages, 11 figure

    Characterisation of Hybrid Pixel Detectors with capacitive charge division

    Get PDF
    In order to fully exploit the physics potential of the future high energy e+ e- linear collider, a Vertex Tracker providing high resolution track reconstruction is required. Hybrid pixel sensors are an attractive technology due to their fast read-out capabilities and radiation hardness. A novel pixel detector layout with interleaved cells between the readout nodes has been developed to improve the single point resolution. The results of the characterisation of the first processed prototypes are reported.Comment: 5 pages, 2 figures, presented at LCWS2000, Linear Collider Workshop, October 24-28 2000, Fermi National Accelerator Laboratory, Batavia, Illinois, U.S.A. Proceedings to be published by the American Institute of Physic

    Patient-reported experience and quality of care for people with schizophrenia

    Get PDF
    BACKGROUND: Evidence is mounting that patient-reported experience can provide a valuable indicator of the quality of healthcare services. However, little is known about the relationship between the experiences of people with severe mental illness and the quality of care they receive. We conducted a study to examine the relationship between patient-reported experience and the quality of care provided to people with schizophrenia. METHODS: We calculated a composite global rating of quality of care for people with schizophrenia using data from an audit of 64 mental health providers. We then examined associations between these ratings and mean patient satisfaction and patient-rated outcome using data from a survey of 5608 schizophrenic patients treated in these services. RESULTS: Global rating of quality of care was positively correlated with patient-rated outcome (r = 0.33; p = 0.01) but not with patient satisfaction (r = 0.21, p = 0.10). Patient-rated outcome was also positively correlated with patient involvement (r = 0.26, p = 0.04) and the quality of prescribing practice (r = 0.31, p = 0.02). High patient satisfaction scores were significantly associated with the extent of use of care plans within each organisation (r = 0.27, p = 0.03). CONCLUSIONS: Among people with schizophrenia, patient-rated outcome provides a better guide to the quality of care than patient-rated satisfaction. Greater use of patient-reported outcome measures should be made when assessing the quality of care provided to people with psychosis

    High resolution pixel detectors for e+e- linear colliders

    Get PDF
    The physics goals at the future e+e- linear collider require high performance vertexing and impact parameter resolution. Two possible technologies for the vertex detector of an experimental apparatus are outlined in the paper: an evolution of the Hybrid Pixel Sensors already used in high energy physics experiments and a new detector concept based on the monolithic CMOS sensors.Comment: 8 pages, to appear on the Proceedings of the International Workshop on Linear Colliders LCWS99, Sitges (Spain), April 28 - May 5, 199

    High Resolution Hybrid Pixel Sensors for the e+e- TESLA Linear Collider Vertex Tracker

    Get PDF
    In order to fully exploit the physics potential of a future high energy e+e- linear collider, a Vertex Tracker, providing high resolution track reconstruction, is required. Hybrid Silicon pixel sensors are an attractive option, for the sensor technology, due to their read-out speed and radiation hardness, favoured in the high rate environment of the TESLA e+e- linear collider design but have been so far limited by the achievable single point space resolution. In this paper, a conceptual design of the TESLA Vertex Tracker, based on a novel layout of hybrid pixel sensors with interleaved cells to improve their spatial resolution, is presented.Comment: 12 pages, 5 figures, to appear in the Proceedings of the Vertex99 Workshop, Texel (The Netherlands), June 199

    Measurements of natural radioactivity in the salt cavern of the Polkowice-Sieroszowice copper mine

    Get PDF
    Due to their low radioactivity background, underground physics laboratories offer a unique possibility for investigating extremely rare phenomena like proton decay, dark matter signals or neutrino physics/astrophysics related issues. The knowledge of the natural radioactivity background is essential for the success of an underground physics experiment. The following measurements of the natural radioactivity background, in the foreseen location of an underground physics laboratory in the salt layer, in the Polkowice–Sieroszowice copper mine are presented: concentration of natural radio-isotopes from in situ obtained gamma-ray spectra and from alpha spectroscopy of rock samples, radon concentration in the air and the dose determination
    • …
    corecore