253 research outputs found
Breast cancer teams: the impact of constitution, new cancer workload, and methods of operation on their effectiveness
National guidance and clinical guidelines recommended multidisciplinary teams (MDTs) for cancer services in order to bring specialists in relevant disciplines together, ensure clinical decisions are fully informed, and to coordinate care effectively. However, the effectiveness of cancer teams was not previously evaluated systematically. A random sample of 72 breast cancer teams in England was studied (548 members in six core disciplines), stratified by region and caseload. Information about team constitution, processes, effectiveness, clinical performance, and members' mental well-being was gathered using appropriate instruments. Two input variables, team workload (P=0.009) and the proportion of breast care nurses (P=0.003), positively predicted overall clinical performance in multivariate analysis using a two-stage regression model. There were significant correlations between individual team inputs, team composition variables, and clinical performance. Some disciplines consistently perceived their team's effectiveness differently from the mean. Teams with shared leadership of their clinical decision-making were most effective. The mental well-being of team members appeared significantly better than in previous studies of cancer clinicians, the NHS, and the general population. This study established that team composition, working methods, and workloads are related to measures of effectiveness, including the quality of clinical care
Exhaled breath condensate pH as a biomarker of COPD severity in ex-smokers
Endogenous airway acidification, as assessed by exhaled breath condensate (EBC) pH, is present in patients with stable COPD. The aim of this study was to measure EBC pH levels in a large cohort of COPD patients and to evaluate associations with functional parameters according to their smoking status
Subcritical Fluctuations at the Electroweak Phase Transition
We study the importance of thermal fluctuations during the electroweak phase
transition. We evaluate in detail the equilibrium number density of large
amplitude subcritical fluctuations and discuss the importance of phase mixing
to the dynamics of the phase transition. Our results show that, for realistic
Higgs masses, the phase transition can be completed by the percolation of the
true vacuum, induced by the presence of subcritical fluctuations.Comment: RevTeX, 4 eps figs (uses epsf.sty), 26 pages, to be published in
Phys. Rev.
ASCR/HEP Exascale Requirements Review Report
This draft report summarizes and details the findings, results, and
recommendations derived from the ASCR/HEP Exascale Requirements Review meeting
held in June, 2015. The main conclusions are as follows. 1) Larger, more
capable computing and data facilities are needed to support HEP science goals
in all three frontiers: Energy, Intensity, and Cosmic. The expected scale of
the demand at the 2025 timescale is at least two orders of magnitude -- and in
some cases greater -- than that available currently. 2) The growth rate of data
produced by simulations is overwhelming the current ability, of both facilities
and researchers, to store and analyze it. Additional resources and new
techniques for data analysis are urgently needed. 3) Data rates and volumes
from HEP experimental facilities are also straining the ability to store and
analyze large and complex data volumes. Appropriately configured
leadership-class facilities can play a transformational role in enabling
scientific discovery from these datasets. 4) A close integration of HPC
simulation and data analysis will aid greatly in interpreting results from HEP
experiments. Such an integration will minimize data movement and facilitate
interdependent workflows. 5) Long-range planning between HEP and ASCR will be
required to meet HEP's research needs. To best use ASCR HPC resources the
experimental HEP program needs a) an established long-term plan for access to
ASCR computational and data resources, b) an ability to map workflows onto HPC
resources, c) the ability for ASCR facilities to accommodate workflows run by
collaborations that can have thousands of individual members, d) to transition
codes to the next-generation HPC platforms that will be available at ASCR
facilities, e) to build up and train a workforce capable of developing and
using simulations and analysis to support HEP scientific research on
next-generation systems.Comment: 77 pages, 13 Figures; draft report, subject to further revisio
The new generation CMB B-mode polarization experiment: POLARBEAR
We describe the Cosmic Microwave Background (CMB) polarization experiment
called Polarbear. This experiment will use the dedicated Huan Tran Telescope
equipped with a powerful 1,200-bolometer array receiver to map the CMB
polarization with unprecedented accuracy. We summarize the experiment, its
goals, and current status
Ultra High Energy Cosmology with POLARBEAR
Observations of the temperature anisotropy of the Cosmic Microwave Background
(CMB) lend support to an inflationary origin of the universe, yet no direct
evidence verifying inflation exists. Many current experiments are focussing on
the CMB's polarization anisotropy, specifically its curl component (called
"B-mode" polarization), which remains undetected. The inflationary paradigm
predicts the existence of a primordial gravitational wave background that
imprints a unique B-mode signature on the CMB's polarization at large angular
scales. The CMB B-mode signal also encodes gravitational lensing information at
smaller angular scales, bearing the imprint of cosmological large scale
structures (LSS) which in turn may elucidate the properties of cosmological
neutrinos. The quest for detection of these signals; each of which is orders of
magnitude smaller than the CMB temperature anisotropy signal, has motivated the
development of background-limited detectors with precise control of systematic
effects. The POLARBEAR experiment is designed to perform a deep search for the
signature of gravitational waves from inflation and to characterize lensing of
the CMB by LSS. POLARBEAR is a 3.5 meter ground-based telescope with 3.8
arcminute angular resolution at 150 GHz. At the heart of the POLARBEAR receiver
is an array featuring 1274 antenna-coupled superconducting transition edge
sensor (TES) bolometers cooled to 0.25 Kelvin. POLARBEAR is designed to reach a
tensor-to-scalar ratio of 0.025 after two years of observation -- more than an
order of magnitude improvement over the current best results, which would test
physics at energies near the GUT scale. POLARBEAR had an engineering run in the
Inyo Mountains of Eastern California in 2010 and will begin observations in the
Atacama Desert in Chile in 2011.Comment: 8 pages, 6 figures, DPF 2011 conference proceeding
The gauge invariant effective potential: equilibrium and non-equilibrium aspects
We propose a gauge invariant formulation of the effective potential in terms
of a gauge invariant order parameter, for the Abelian Higgs model. The one-loop
contribution at zero and finite temperature is computed explicitly, and the
leading terms in the high temperature expansion are obtained. The result is
contrasted to the effective potential obtained in several covariant
gauge-fixing schemes, and the gauge invariant quantities that can be reliably
extracted from these are identified. It is pointed out that the gauge invariant
effective potential in the one-loop approximation is complex for {\em all
values} of the order parameter between the maximum and the minimum of the tree
level potential, both at zero and non-zero temperature. The imaginary part is
related to long-wavelength instabilities towards phase separation. We study the
real-time dynamics of initial states in the spinodal region, and relate the
imaginary part of the effective potential to the growth rate of equal-time
gauge invariant correlation functions in these states. We conjecture that the
spinodal instabilities may play a role in non-equilibrium processes {\em
inside} the nucleating bubbles if the transition is first order.Comment: 27 pages revtex 3.0, no figures; one reference adde
The bolometric focal plane array of the Polarbear CMB experiment
The Polarbear Cosmic Microwave Background (CMB) polarization experiment is
currently observing from the Atacama Desert in Northern Chile. It will
characterize the expected B-mode polarization due to gravitational lensing of
the CMB, and search for the possible B-mode signature of inflationary
gravitational waves. Its 250 mK focal plane detector array consists of 1,274
polarization-sensitive antenna-coupled bolometers, each with an associated
lithographed band-defining filter. Each detector's planar antenna structure is
coupled to the telescope's optical system through a contacting dielectric
lenslet, an architecture unique in current CMB experiments. We present the
initial characterization of this focal plane
Comparison of exhaled breath condensate pH using two commercially available devices in healthy controls, asthma and COPD patients
<p>Abstract</p> <p>Background</p> <p>Analysis of exhaled breath condensate (EBC) is a non-invasive method for studying the acidity (pH) of airway secretions in patients with inflammatory lung diseases.</p> <p>Aim</p> <p>To assess the reproducibility of EBC pH for two commercially available devices (portable RTube and non-portable ECoScreen) in healthy controls, patients with asthma or COPD, and subjects suffering from an acute cold with lower-airway symptoms. In addition, we assessed the repeatability in healthy controls.</p> <p>Methods</p> <p>EBC was collected from 40 subjects (n = 10 in each of the above groups) using RTube and ECoScreen. EBC was collected from controls on two separate occasions within 5 days. pH in EBC was assessed after degasification with argon for 20 min.</p> <p>Results</p> <p>In controls, pH-measurements in EBC collected by RTube or ECoScreen showed no significant difference between devices (p = 0.754) or between days (repeatability coefficient RTube: 0.47; ECoScreen: 0.42) of collection. A comparison between EBC pH collected by the two devices in asthma, COPD and cold patients also showed good reproducibility. No differences in pH values were observed between controls (mean pH 8.27; RTube) and patients with COPD (pH 7.97) or asthma (pH 8.20), but lower values were found using both devices in patients with a cold (pH 7.56; RTube, p < 0.01; ECoScreen, p < 0.05).</p> <p>Conclusion</p> <p>We conclude that pH measurements in EBC collected by RTube and ECoScreen are repeatable and reproducible in healthy controls, and are reproducible and comparable in healthy controls, COPD and asthma patients, and subjects with a common cold.</p
- …