29 research outputs found

    Elderly patient: which vascular access? Choice and management of vascular access in the elderly patient:

    Get PDF
    The optimal vascular access for elderly patients remains a challenge due to the difficult balance between risks and benefits in a population with increased comorbidity and decreased survival. Long dependence to central vein catheter, patient comorbidities, life expectancy, and complication rates are important influencing the indications for arteriovenous fistula or an arteriovenous graft. Although central vein catheters are simpler way to start a hemodialysis treatment, elderly patients are also at higher risk of death from infection or other complications associated with them more than for younger patients. The discussion revolves around the following key questions: What are the limiting factors for a vascular access in the elderly patients? Central venous catheter—is it still an option for elderly patients? Is still the autologous arteriovenous fistula playing a pivotal role as hemodialysis access in the elderly patients? Are there any real surgical contraindication to perform a vascular access in elderly patients? Is the old age a limiting factor for the vascular access management

    Novel Technique for Intentional Occlusion of Directional Branches During Complex Endovascular Aortic Repair Using Microvascular Plugs

    Get PDF
    Purpose: To demonstrate the feasibility and outcomes of using the microvascular plug (MVP) for intentional occlusion of directional branches (DB) during complex endovascular aortic procedures. Case report: Two patients were treated with the off-the-shelf four-branched Zenith t-Branch thoracoabdominal stent-graft (Cook Medical, Bloomington, Ind). In both cases, the renal arteries (on one side in patient #1 and on both sides in patient #2, respectively) were occluded at time of index intervention. Preoperative planning included the intentional occlusion of each DB with one 7Q-MVP. Technical success was achieved in all cases and maintained at mid-term follow-up (12 months and 36 months, respectively). Conclusions: Use of the MVP appears to be feasible and effective for intentional occlusion of DB during complex endovascular aortic repair. This novel and simple technique may present some unique technical advantages, allowing precise placement of the device while avoiding extension using a bridging stent and DB cannulation with larger sheaths

    Cervical pessary for preventing preterm birth in twin pregnancies with short cervical length: a systematic review and meta-analysis

    Get PDF
    OBJECTIVE: To evaluate the effectiveness of cervical pessary for preventing spontaneous preterm birth (SPTB) in twin pregnancies with an asymptomatic transvaginal ultrasound cervical length (TVU CL) in the second trimester. METHODS: We performed a meta-analysis including all randomized clinical trials (RCTs) comparing the use of cervical pessary (i.e. intervention group) with expectant management (i.e. control group). The primary outcome was incidence of SPTB <34 weeks. RESULTS: Three trials, including 481 twin pregnancies with short cervix, were analyzed. Two RCTs defined short cervix as TVU CL ≀25 mm and one as TVU CL ≀38 mm. Pessary was not associated with prevention of SPTB, and the mean gestational age at delivery and the mean latency were similar in the pessary group compared to the control group. Moreover, no benefits were noticed in neonatal outcomes.\ud CONCLUSIONS: Use of the Arabin pessary in twin pregnancies with short TVU CL at 16-24 weeks does not prevent SPTB or improve perinatal outcome

    Risk factors associated with adverse fetal outcomes in pregnancies affected by Coronavirus disease 2019 (COVID-19): a secondary analysis of the WAPM study on COVID-19.

    Get PDF
    Objectives To evaluate the strength of association between maternal and pregnancy characteristics and the risk of adverse perinatal outcomes in pregnancies with laboratory confirmed COVID-19. Methods Secondary analysis of a multinational, cohort study on all consecutive pregnant women with laboratory-confirmed COVID-19 from February 1, 2020 to April 30, 2020 from 73 centers from 22 different countries. A confirmed case of COVID-19 was defined as a positive result on real-time reverse-transcriptase-polymerase-chain-reaction (RT-PCR) assay of nasal and pharyngeal swab specimens. The primary outcome was a composite adverse fetal outcome, defined as the presence of either abortion (pregnancy loss before 22 weeks of gestations), stillbirth (intrauterine fetal death after 22 weeks of gestation), neonatal death (death of a live-born infant within the first 28 days of life), and perinatal death (either stillbirth or neonatal death). Logistic regression analysis was performed to evaluate parameters independently associated with the primary outcome. Logistic regression was reported as odds ratio (OR) with 95% confidence interval (CI). Results Mean gestational age at diagnosis was 30.6+/-9.5 weeks, with 8.0% of women being diagnosed in the first, 22.2% in the second and 69.8% in the third trimester of pregnancy. There were six miscarriage (2.3%), six intrauterine device (IUD) (2.3) and 5 (2.0%) neonatal deaths, with an overall rate of perinatal death of 4.2% (11/265), thus resulting into 17 cases experiencing and 226 not experiencing composite adverse fetal outcome. Neither stillbirths nor neonatal deaths had congenital anomalies found at antenatal or postnatal evaluation. Furthermore, none of the cases experiencing IUD had signs of impending demise at arterial or venous Doppler. Neonatal deaths were all considered as prematurity-related adverse events. Of the 250 live-born neonates, one (0.4%) was found positive at RT-PCR pharyngeal swabs performed after delivery. The mother was tested positive during the third trimester of pregnancy. The newborn was asymptomatic and had negative RT-PCR test after 14 days of life. At logistic regression analysis, gestational age at diagnosis (OR: 0.85, 95% CI 0.8-0.9 per week increase; pPeer reviewe

    Maternal and perinatal outcomes of pregnant women with SARS-CoV-2 infection.

    Get PDF
    OBJECTIVES: To evaluate the maternal and perinatal outcomes of pregnancies affected by SARS-CoV-2 infection. METHODS: This was a multinational retrospective cohort study including women with a singleton pregnancy and laboratory-confirmed SARS-CoV-2 infection, conducted in 72 centers in 22 different countries in Europe, the USA, South America, Asia and Australia, between 1 February 2020 and 30 April 2020. Confirmed SARS-CoV-2 infection was defined as a positive result on real-time reverse-transcription polymerase chain reaction (RT-PCR) assay of nasopharyngeal swab specimens. The primary outcome was a composite measure of maternal mortality and morbidity, including admission to the intensive care unit (ICU), use of mechanical ventilation and death. RESULTS: In total, 388 women with a singleton pregnancy tested positive for SARS-CoV-2 on RT-PCR of a nasopharyngeal swab and were included in the study. Composite adverse maternal outcome was observed in 47/388 (12.1%) women; 43 (11.1%) women were admitted to the ICU, 36 (9.3%) required mechanical ventilation and three (0.8%) died. Of the 388 women included in the study, 122 (31.4%) were still pregnant at the time of data analysis. Among the other 266 women, six (19.4% of the 31 women with first-trimester infection) had miscarriage, three (1.1%) had termination of pregnancy, six (2.3%) had stillbirth and 251 (94.4%) delivered a liveborn infant. The rate of preterm birth before 37 weeks' gestation was 26.3% (70/266). Of the 251 liveborn infants, 69/251 (27.5%) were admitted to the neonatal ICU, and there were five (2.0%) neonatal deaths. The overall rate of perinatal death was 4.1% (11/266). Only one (1/251, 0.4%) infant, born to a mother who tested positive during the third trimester, was found to be positive for SARS-CoV-2 on RT-PCR. CONCLUSIONS: SARS-CoV-2 infection in pregnant women is associated with a 0.8% rate of maternal mortality, but an 11.1% rate of admission to the ICU. The risk of vertical transmission seems to be negligible. © 2020 International Society of Ultrasound in Obstetrics and Gynecology

    Tools

    No full text

    Effect Of Branch Length And Tortuosity On The Outcomes Of Branched Endovascular Repair Of Thoracoabdominal Aneurysms Using Self Expandable bridging stent-graft

    No full text
    To investigate the effect of length and tortuosity of directional branches on the mid-term outcomes of branched endovascular aneurysm repair (BEVAR) for thoracoabdominal aortic aneurysms (TAAA)

    Preliminary experience with new generation balloon expandable stent-graft in the treatment of innominate artery obstructive disease

    No full text
    To describe a single center preliminary experience with the use of a specific balloon expandable stent-graft for the treatment of innominate artery (IA) obstructive lesions
    corecore