8 research outputs found

    Thermodynamic temperatures of high-temperature fixed points: uncertainties due to temperature drop and emissivity

    Get PDF
    This study forms part of the European Metrology Research Programme project implementing the New Kelvin to assign thermodynamic temperatures to a selected set of high-temperature fixed points (HTFPs), Cu, Co–C, Pt–C, and Re–C. A realistic thermal model of these HTFPs, developed in finite volume software ANSYS FLUENT, was constructed to quantify the uncertainty associated with the temperature drop across the back wall of the cell. In addition, the widely applied software package, STEEP3 was used to investigate the influence of cell emissivity. The temperature drop, ΔT, relates to the temperature difference due to the net loss of heat from the aperture of the cavity between the back wall of the cavity, viewed by the thermometer, defining the radiance temperature, and the solid–liquid interface of the alloy, defining the transition temperature of the HTFP. The actual value of ΔT can be used either as a correction (with associated uncertainty) to thermodynamic temperature evaluations of HTFPs, or as an uncertainty contribution to the overall estimated uncertainty. In addition, the effect of a range of furnace temperature profiles on the temperature drop was calculated and found to be negligible for Cu, Co–C, and Pt–C and small only for Re–C. The effective isothermal emissivity (εeff) is calculated over the wavelength range from 450 nm to 850 nm for different assumed values of surface emissivity. Even when furnace temperature profiles are taken into account, the estimated emissivities change only slightly from the effective isothermal emissivity of the bare cell. These emissivity calculations are used to estimate the uncertainty in the temperature assignment due to the uncertainty in the emissivity of the blackbody

    Is surgical antibiotic prophylaxis necessary for pediatric orchiopexy?

    Get PDF
    Introduction Surgeons frequently use surgical antibiotic prophylaxis (SAP), despite limited evidence to support its efficacy. Potential adverse events associated with antibiotic use include allergic reaction (including anaphylaxis), Clostridium difficile infection, and selecting for resistant bacteria. Surgical site infections (SSI) are very rare in patients undergoing clean pediatric urologic procedures. Current guidelines are unclear about the efficacy of surgical antibiotic prophylaxis for prevention of SSI in the pediatric population. Objective It was hypothesized that children who received SAP prior to orchiopexy would have no reduction in surgical site infection (SSI) risk but an increased risk of antibiotic-associated adverse events. Methods A retrospective cohort study was conducted of all males aged between 30 days and 18 years who underwent an orchiopexy (ICD-9 CM 62.5) in an ambulatory or observation setting from 2004 to 2015 using the Pediatric Health Information System database. Inpatients and those with concomitant procedures were excluded. Chi-squared or Fisher's exact tests were used to determine the association between SAP and allergic reaction (defined as a charge for epinephrine or ICD-9 diagnosis code for allergic reaction on the date of surgery) and any of the following within 30 days: SSI, hospital readmission or any repeat hospital encounter. Mixed effects logistic regression was performed, controlling for age, race, and insurance, and clustering of similar practice patterns by hospital. Results A total of 71,767 patients were included: median age was 4.6 years, 61.4% were white, and 49.3% had public insurance; 33.5% received SAP. Of these participants, 996/71,767 (1.4%) had a perioperative allergic reaction and <0.1% were diagnosed with an SSI. On mixed effects logistic regression, those who received SAP had 1.2 times the odds of a perioperative allergic reaction compared with those who did not receive SAP ( P = 0.005). Surgical antibiotic prophylaxis was not associated with decreased rates of SSI, lower hospital readmission, nor a lower chance of a repeat encounter within 30 days. Conclusions In patients undergoing orchiopexy, it was found that SAP did not reduce the risk of postoperative SSI, readmissions, or hospital visits. Patients who received SAP had significantly increased odds of perioperative allergic reaction. This demonstrated that the risks of SAP outweigh the benefits in children undergoing orchiopexy

    Reliability of a novel thermal imaging system for temperature assessment of healthy feet

    Get PDF
    Abstract Background Thermal imaging is a useful modality for identifying preulcerative lesions (“hot spots”) in diabetic foot patients. Despite its recognised potential, at present, there is no readily available instrument for routine podiatric assessment of patients at risk. To address this need, a novel thermal imaging system was recently developed. This paper reports the reliability of this device for temperature assessment of healthy feet. Methods Plantar skin foot temperatures were measured with the novel thermal imaging device (Diabetic Foot Ulcer Prevention System (DFUPS), constructed by Photometrix Imaging Ltd) and also with a hand-held infrared spot thermometer (Thermofocus® 01500A3, Tecnimed, Italy) after 20 min of barefoot resting with legs supported and extended in 105 subjects (52 males and 53 females; age range 18 to 69 years) as part of a multicentre clinical trial. The temperature differences between the right and left foot at five regions of interest (ROIs), including 1st and 4th toes, 1st, 3rd and 5th metatarsal heads were calculated. The intra-instrument agreement (three repeated measures) and the inter-instrument agreement (hand-held thermometer and thermal imaging device) were quantified using intra-class correlation coefficients (ICCs) and the 95% confidence intervals (CI). Results Both devices showed almost perfect agreement in replication by instrument. The intra-instrument ICCs for the thermal imaging device at all five ROIs ranged from 0.95 to 0.97 and the intra-instrument ICCs for the hand-held-thermometer ranged from 0.94 to 0.97. There was substantial to perfect inter-instrument agreement between the hand-held thermometer and the thermal imaging device and the ICCs at all five ROIs ranged between 0.94 and 0.97. Conclusions This study reports the performance of a novel thermal imaging device in the assessment of foot temperatures in healthy volunteers in comparison with a hand-held infrared thermometer. The newly developed thermal imaging device showed very good agreement in repeated temperature assessments at defined ROIs as well as substantial to perfect agreement in temperature assessment with the hand-held infrared thermometer. In addition to the reported non-inferior performance in temperature assessment, the thermal imaging device holds the potential to provide an instantaneous thermal image of all sites of the feet (plantar, dorsal, lateral and medial views). Trial registration Diabetic Foot Ulcer Prevention System NCT02317835, registered December 10, 201

    Acetylcholin-Esterase

    No full text
    corecore