28,329 research outputs found

    Digital demodulation with data subcarrier tracking

    Get PDF
    Digital demodulator is based on early-late bit timing scheme coupled with Costas data tracking loop. System is successful in enhancement of weak signals from space where atmospheric and other interference media cause bit error rate to reach excessive level

    Computer programs for the design of liquid-to-liquid jet pumps

    Get PDF
    Computer programs based on one-dimensional equations for cavitating and noncavitating flow in liquid-to-liquid jet pumps are described

    Digital demodulation with data subcarrier tracking

    Get PDF
    Digital demodulation with data subcarrier trackin

    Comparison of calculated and experimental cascade performance for controlled-diffusion compressor stator blading

    Get PDF
    The mid-span section of a previously reported controlled-diffusion compressor stator has been experimentally evaluated in cascade. Measurements are taken over a range of incidence angles for blade chord Reynolds numbers from 470,000 to 690,000. Blade chord length is 12.7 cm, aspect ratio is 2.0, and solidity is 1.67. Measurements include conventional cascade performance parameters as well as blade surface pressures. Computations are made for the inviscid flow field, surface boundary layers, and loss for several of the blade inlet angle conditions, are compared against corresponding data

    The effect of circumferential distortion on fan performance at two levels of blade loading

    Get PDF
    Single stage fans designed for two levels of pressure ratio or blade loading were subjected to screen-induced circumferential distortions of 90-degree extent. Both fan rotors were designed for a blade tip speed of 425 m/sec, blade solidity of 1.3 and a hub-to-tip radius ratio of 0.5. Circumferential measurements of total pressure, temperature, static pressure, and flow angle were obtained at the hub, mean and tip radii at five axial stations. Rotor loading level did not appear to have a significant influence on rotor response to distorted flow. Losses in overall pressure ratio due to distortion were most severe in the stator hub region of the more highly loaded stage. At the near stall operating condition tip and hub regions of (either) rotor demonstrated different response characteristics to the distorted flow. No effect of loading was apparent on interactions between rotor and upstream distorted flow fields

    Some observations of the effects of radial distortions on performance of a transonic rotating blade row

    Get PDF
    A single rotating blade row was tested with two magnitudes of tip radial distortion and two magnitudes of hub radial distortion imposed on the inlet flow. The rotor was about 50 centimeters (20 in.) in diameter and had a design operating tip speed of approximately 420 meters per second (1380 ft/sec). Overall performance at 60, 80, and 100 percent of equivalent design speed generally showed a decrease (compared to undistorted flow) in rotor stall margin with tip radial distortion but no change, or a slight increase, in rotor stall margin with hub radial distortion. At design speed there was a decrease in rotor overall total pressure ratio and choke flow with all inlet flow distortions. Radial distributions of blade element parameters are presented for selected operating conditions at design speed

    Static performance of a 13.97 cm (5.5 inch) diameter model VTOL lift fan

    Get PDF
    A tip-turbine-driven fan of the type currently being used in wind tunnel tests of VTOL lift fan models was tested. Values of thrust, weight flow, exit total and static pressure, exit swirl angle, and turbine temperature drop were measured as a function of fan speed for several inlet and exit configurations. A standard fan performance map was also obtained
    corecore