205 research outputs found

    A hydrothermal route to water-stable luminescent carbon dots as nanosensors for pH and temperature

    No full text
    Carbon dots (CDs) as a class of heavy-metal-free fluorescent nanomaterials has drawn increasing attention in recent years due to their high optical absorptivity, chemical stability, biocompatibility, and low toxicity. Herein, we report a facile method to prepare stable CDs by hydrothermal treatment of glucose (glc) in the presence of glutathione (GSH). With this approach, the formation and the surface passivation of CDs are carried out simultaneously, resulting in intrinsic fluorescence emission. The influence of reaction temperature, reaction time and feed ratio of GSH/glc on the photoluminescence property of CDs is studied. The as-prepared CDs are characterized by UV–Vis, photoluminescence, X-ray photoelectron spectroscopy, Fourier transform infrared spectroscopy and transmission electron microscope, from which their structural information and property are interpreted. These CDs may be useful as pH sensors or as versatile nanothermometry devices based on the pronounced temperature dependence of their steady-state fluorescence emission spectra, which changes considerably over the physiological temperature range (15–60 °C).This work was supported by the National Natural Science Foundation of China (No. 50925207), the Natural Science Foundation of Jiangsu Province, China (BK20140157), Programme of Introducing Talents of Discipline to Universities (111 Project B13025), and the Fundamental Research Funds for the Central Universities (JUSRP11418)

    Radar-lidar ratio for ice crystals of cirrus clouds

    Get PDF
    Simultaneous measurement of lidar and radar signals returned from the same cirrus clouds is a prospective method for retrieving the cloud microphysics, i.e. size and shape of the ice crystals constituting the clouds. In this study, the ratio of the backscattered signals of lidar and radar called the radar-lidar ratio has been calculated for the ʱrst time for typical shapes of ice crystals and wide distribution of the crystals over their sizes. It is shown that it is the lidar-radar ratio that is most sensitive to crystal sizes while the lidar depolarization ratio is most sensitive to crystal shape

    Азимутальная симметрия в матрице рассеяния для хаотически ориентированных частиц сложной формы

    Get PDF
    Проведен численный расчет матрицы рассеяния света для нерегулярного многогранника с размерами, превышающими длину волны падающего света в 150 раз. Показано, что при хаотической ориентации частицы часть элементов матрицы проявляют симметрию по азимутальному углу рассеяния. Такая симметрия различна для разных элементов матрицы, но одинакова для различных форм частиц. В данном сообщении мы доказываем, что эта симметрия является результатом усреднения матриц рассеяния, в основном, из-за вращения частицы вокруг направления падения света

    Tunable Carbon-Dot-Based Dual-Emission Fluorescent Nanohybrids for Ratiometric Optical Thermometry in Living Cells

    Get PDF
    The use of carbon-dot-based dual-emission fluorescent nanohybrids (DEFNs) as versatile nanothermometry devices for spatially resolved temperature measurements in living cells is demonstrated. The carbon dots (CDs) are prepared in the organic phase and display tunable photoluminescence (PL) across a wide visible range by adjusting the excitation wavelengths and extend of N-doping. DEFNs are formed in a straightforward fashion from CDs (emitting blue PL) and gold nanoclusters (AuNCs, emitting red PL). The DEFNs display ideal single-excitation, dual-emission with two well-resolved, intensity-comparable fluorescence peaks, and function in optical thermometry with high reliability and accuracy by exploiting the temperature sensitivity of their fluorescence intensity ratio (blue/red). Furthermore, the DEFNs have been introduced into cells, exhibiting good biocompatibility, and have facilitated physiological temperature measurements in the range of 25-45 °C; the DEFNs can therefore function as "non-contact" tools for the accurate measurement of temperature and its gradient inside a living cell.This work was supported by the National Natural Science Foundation of China (Nos. 50925207, 51432006, and 51503085), the Ministry of Science and Technology of China for the International Science Linkages Program (No. 2011DFG52970), the Natural Science Foundation of Jiangsu Province, China (No. BK20140157), the Changjiang Innovation Research Team (IRT14R23), the Programme of Introducing Talents of Discipline to Universities (111 Project B13025). M.G.H. and C.Z. thank the Australian Research Council (ARC) for support

    Own-Race Faces Capture Attention Faster than Other-Race Faces: Evidence from Response Time and the N2pc

    Get PDF
    Studies have shown that people are better at recognizing human faces from their own-race than from other-races, an effect often termed the Own-Race Advantage. The current study investigates whether there is an Own-Race Advantage in attention and its neural correlates. Participants were asked to search for a human face among animal faces. Experiment 1 showed a classic Own-Race Advantage in response time both for Chinese and Black South African participants. Using event-related potentials (ERPs), Experiment 2 showed a similar Own-Race Advantage in response time for both upright faces and inverted faces. Moreover, the latency of N2pc for own-race faces was earlier than that for other-race faces. These results suggested that own-race faces capture attention more efficiently than other-race faces

    Development of an incoherent broad-band cavity-enhanced aerosol extinction spectrometer and its application to measurement of aerosol optical hygroscopicity

    Get PDF
    We report on the development of a blue light-emitting-diode-based incoherent broad-band cavity-enhanced absorption spectroscopy (IBBCEAS) instrument for the measurement of the aerosol extinction coefficient at \u1d706=461  nm. With an effective absorption path length of 2.8 km, an optimum detection limit of 0.05  Mm−1 (5×10−10  cm−1) was achieved with an averaging time of 84 s. The baseline drift of the developed spectrometer was about ±0.3  Mm−1 over 2.5 h (1\u1d70e standard deviation). The performance of the system was evaluated with laboratory-generated monodispersed polystyrene latex (PSL) spheres. The retrieved complex refractive index of PSL agreed well with previously reported values. The relative humidity (RH) dependence of the aerosol extinction coefficient was measured using IBBCEAS. The measured extinction enhancement factor values for 200 nm dry ammonium sulphate particles at different RH were in good agreement with the modeled values. Field performance of the aerosol extinction spectrometer was demonstrated at the Hefei Radiation Observatory site

    Simplified HIV Testing and Treatment in China: Analysis of Mortality Rates Before and After a Structural Intervention.

    Get PDF
    BackgroundMultistage stepwise HIV testing and treatment initiation procedures can result in lost opportunities to provide timely antiretroviral therapy (ART). Incomplete patient engagement along the continuum of HIV care translates into high levels of preventable mortality. We aimed to evaluate the ability of a simplified test and treat structural intervention to reduce mortality.Methods and findingsIn the "pre-intervention 2010" (from January 2010 to December 2010) and "pre-intervention 2011" (from January 2011 to December 2011) phases, patients who screened HIV-positive at health care facilities in Zhongshan and Pubei counties in Guangxi, China, followed the standard-of-care process. In the "post-intervention 2012" (from July 2012 to June 2013) and "post-intervention 2013" (from July 2013 to June 2014) phases, patients who screened HIV-positive at the same facilities were offered a simplified test and treat intervention, i.e., concurrent HIV confirmatory and CD4 testing and immediate initiation of ART, irrespective of CD4 count. Participants were followed for 6-18 mo until the end of their study phase period. Mortality rates in the pre-intervention and post-intervention phases were compared for all HIV cases and for treatment-eligible HIV cases. A total of 1,034 HIV-positive participants (281 and 339 in the two pre-intervention phases respectively, and 215 and 199 in the two post-intervention phases respectively) were enrolled. Following the structural intervention, receipt of baseline CD4 testing within 30 d of HIV confirmation increased from 67%/61% (pre-intervention 2010/pre-intervention 2011) to 98%/97% (post-intervention 2012/post-intervention 2013) (all p < 0.001 [i.e., for all comparisons between a pre- and post-intervention phase]), and the time from HIV confirmation to ART initiation decreased from 53 d (interquartile range [IQR] 27-141)/43 d (IQR 15-113) to 5 d (IQR 2-12)/5 d (IQR 2-13) (all p < 0.001). Initiation of ART increased from 27%/49% to 91%/89% among all cases (all p < 0.001) and from 39%/62% to 94%/90% among individuals with CD4 count ≤ 350 cells/mm3 or AIDS (all p < 0.001). Mortality decreased from 27%/27% to 10%/10% for all cases (all p < 0.001) and from 40%/35% to 13%/13% for cases with CD4 count ≤ 350 cells/mm3 or AIDS (all p < 0.001). The simplified test and treat intervention was significantly associated with decreased mortality rates compared to pre-intervention 2011 (adjusted hazard ratio [aHR] 0.385 [95% CI 0.239-0.620] and 0.380 [95% CI 0.233-0.618] for the two post-intervention phases, respectively, for all newly diagnosed HIV cases [both p < 0.001], and aHR 0.369 [95% CI 0.226-0.603] and 0.361 [95% CI 0.221-0.590] for newly diagnosed treatment-eligible HIV cases [both p < 0.001]). The unit cost of an additional patient receiving ART attributable to the intervention was US83.80.TheunitcostofadeathpreventedbecauseoftheinterventionwasUS83.80. The unit cost of a death prevented because of the intervention was US234.52.ConclusionsOur results demonstrate that the simplified HIV test and treat intervention promoted successful engagement in care and was associated with a 62% reduction in mortality. Our findings support the implementation of integrated HIV testing and immediate access to ART irrespective of CD4 count, in order to optimize the impact of ART

    Polarization lidars with conical scanning for retrieving the microphysical characteristics of cirrus clouds

    Get PDF
    The paper presents the first results of observations of cirrus clouds by polarization lidars with conical scanning, which were developed in Hefei (China) and in Tomsk (Russia). The light scattering matrix of ice crystal particles of cirrus clouds has been calculated for the first by the authors within the framework of the physical optics approximations in the case of conical scanning lidar. It is found that in this case the Mueller matrix consists of ten non-zero elements, four of which are small and can’t be applied to interpret the azimuthal distribution of particle orientation. All the diagonal elements have a strong azimuthal dependence. Among the off-diagonal elements only one element M34 carries additional information for interpreting the azimuthal distribution. © (2015) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only

    Gazelle: A Low Latency Framework for Secure Neural Network Inference

    Full text link
    The growing popularity of cloud-based machine learning raises a natural question about the privacy guarantees that can be provided in such a setting. Our work tackles this problem in the context where a client wishes to classify private images using a convolutional neural network (CNN) trained by a server. Our goal is to build efficient protocols whereby the client can acquire the classification result without revealing their input to the server, while guaranteeing the privacy of the server's neural network. To this end, we design Gazelle, a scalable and low-latency system for secure neural network inference, using an intricate combination of homomorphic encryption and traditional two-party computation techniques (such as garbled circuits). Gazelle makes three contributions. First, we design the Gazelle homomorphic encryption library which provides fast algorithms for basic homomorphic operations such as SIMD (single instruction multiple data) addition, SIMD multiplication and ciphertext permutation. Second, we implement the Gazelle homomorphic linear algebra kernels which map neural network layers to optimized homomorphic matrix-vector multiplication and convolution routines. Third, we design optimized encryption switching protocols which seamlessly convert between homomorphic and garbled circuit encodings to enable implementation of complete neural network inference. We evaluate our protocols on benchmark neural networks trained on the MNIST and CIFAR-10 datasets and show that Gazelle outperforms the best existing systems such as MiniONN (ACM CCS 2017) by 20 times and Chameleon (Crypto Eprint 2017/1164) by 30 times in online runtime. Similarly when compared with fully homomorphic approaches like CryptoNets (ICML 2016) we demonstrate three orders of magnitude faster online run-time

    Enhanced heating rate of black carbon above planetary boundary layer over megacities in summertime

    Get PDF
    The fast development of a secondary aerosol layer was observed over megacities in eastern Asia during summertime. Within three hours, from midday to early afternoon, the contribution of secondary aerosols above the planetary boundary layer (PBL) increased by a factor of 3-5, and the coatings on the black carbon (BC) also increased and enhanced its absorption efficiency by 50%. This tended to result from the intensive actinic flux received above the PBL which promoted the photochemical reactions. The absorption of BC could be further amplified by the strong reflection of solar radiation over the cloud top across the PBL. This enhanced heating effect of BC introduced by combined processes (intensive solar radiation, secondary formation and cloud reflection) may considerably increase the temperature inversion above the PBL. This mechanism should be considered when evaluating the radiative impact of BC, especially for the polluted regions receiving strong solar radiation
    corecore