824 research outputs found

    Adsorptive graphene doping: Effect of a polymer contaminant

    Get PDF
    © 2017 Author(s). Transfer-induced contamination of graphene and the limited stability of adsorptive dopants are two of the main issues faced in the practical realization of graphene-based electronics. Herein, we assess the stability of HNO3, MoO3, and AuCl3 dopants upon transferred graphene with different extents of polymer contamination. Sheet resistivity measurements prove that polymer residues induce a significantly degenerative effect in terms of doping stability for HNO3 and MoO3 and a highly stabilizing effect for AuCl3. Further characterization by Raman spectroscopy and atomic force microscopy (AFM) provides insight into the stability mechanism. Together, these findings demonstrate the relevance of contamination in the field of adsorptive doping for the realization of graphene-based functional devices

    Optical detection of single non-absorbing molecules using the surface plasmon of a gold nanorod

    Full text link
    Current optical detection schemes for single molecules require light absorption, either to produce fluorescence or direct absorption signals. This severely limits the range of molecules that can be detected, because most molecules are purely refractive. Metal nanoparticles or dielectric resonators detect non-absorbing molecules by a resonance shift in response to a local perturbation of the refractive index, but neither has reached single-protein sensitivity. The most sensitive plasmon sensors to date detect single molecules only when the plasmon shift is amplified by a highly polarizable label or by a localized precipitation reaction on the particle's surface. Without amplification, the sensitivity only allows for the statistical detection of single molecules. Here we demonstrate plasmonic detection of single molecules in realtime, without the need for labeling or amplification. We monitor the plasmon resonance of a single gold nanorod with a sensitive photothermal assay and achieve a ~ 700-fold increase in sensitivity compared to state-of-the-art plasmon sensors. We find that the sensitivity of the sensor is intrinsically limited due to spectral diffusion of the SPR. We believe this is the first optical technique that detects single molecules purely by their refractive index, without any need for photon absorption by the molecule. The small size, bio-compatibility and straightforward surface chemistry of gold nanorods may open the way to the selective and local detection of purely refractive proteins in live cells

    Comparative evaluation of diode laser versus argon laser photocoagulation in patients with central serous retinopathy: A pilot, randomized controlled trial [ISRCTN84128484]

    Get PDF
    BACKGROUND: To evaluate the efficacy of diode laser photocoagulation in patients with central serous retinopathy (CSR) and to compare it with the effects of argon green laser. METHODS: Thirty patients with type 1 unilateral CSR were enrolled and evaluated on parameters like best corrected visual acuity (BCVA), direct and indirect ophthalmoscopy, amsler grid for recording scotoma and metamorphopsia, contrast sensitivity using Cambridge low contrast gratings and fluorescein angiography to determine the site of leakage. Patients were randomly assigned into 2 groups according to the statistical random table using sequence generation. In Group 1 (n = 15), diode laser (810 nm) photocoagulation was performed at the site of leakage while in Group 2 (n = 15), eyes were treated with argon green laser (514 nm) using the same laser parameters. Patients were followed up at 4, 8 and 12 weeks after laser. RESULTS: The mean BCVA in group 1 improved from a pre-laser decimal value of 0.29 ± 0.14 to 0.84 ± 0.23 at 4 weeks and 1.06 ± 0.09 at 12 weeks following laser. In group 2, the same improved from 0.32 ± 0.16 to 0.67 ± 0.18 at 4 weeks and 0.98 ± 0.14 at 12 weeks following laser. The improvement in BCVA was significantly better in group 1 (p < 0.0001) at 4 weeks. At 4 weeks following laser, all the patients in group1 were free of scotoma while 6 patients in group 2 had residual scotoma (p < 0.05). The mean contrast sensitivity in group 1 improved from pre-laser value of 98.4 ± 24.77 to 231.33 ± 48.97 at 4 weeks and 306.00 ± 46.57 at 12 weeks following laser. In group 2, the same improved from 130.66 ± 31.95 to 190.66 ± 23.44 at 4 weeks and 215.33 ± 23.25 at 12 weeks. On comparative evaluation, a significantly better (p < 0.001) improvement was noted in group 1. CONCLUSION: Diode laser may be a better alternative to argon green laser whenever laser treatment becomes indicated in patients with central serous retinopathy in terms of faster visual rehabilitation and better contrast sensitivity. In addition, diode laser also has the well-recognized ergonomic and economic advantages

    A firearm bullet lodged into the thoracic spinal canal without vertebral bone destruction: a case report

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>Firearm injuries account for 13% to 17% of all spinal cord injuries, and are generally caused during warfare or assault with intent to kill. Spinal cord injuries caused by firearms are usually observed in patients aged 15 to 34 years old, and are especially common among men.</p> <p>Case presentation</p> <p>We report the case of a 28-year-old Iraqi man who was referred to our radiology department with lower limb paraplegia secondary to a gunshot wound. We performed 64-slice computerized tomography with two-dimensional and three-dimensional reconstruction of the thoracolumbar spine. On the two-dimensional and three-dimensional reconstructed axial images of the thoracolumbar spine, an intra-canalicular bullet nucleus was found at the mid-spinal cord at the T8 level, with no evidence of vertebral bone destruction.</p> <p>Conclusions</p> <p>To the best of our knowledge, there is only one previous report in the literature describing a case of a bullet nucleus lodged into the inferior epidural spinal canal without destruction of the vertebral bone. With the rise of violence worldwide the incidence of gunshot injuries continues to increase, and, thus, it is essential for radiologists to have a clear understanding of gunshot injuries and the findings on radiographic images.</p

    Clinical relevance of "withdrawal therapy" as a form of hormonal manipulation for breast cancer

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>It has been shown in in-vitro experiments that "withdrawal" of tamoxifen inhibits growth of tumor cells. However, evidence is scarce when this is extrapolated into clinical context. We report our experience to verify the clinical relevance of "withdrawal therapy".</p> <p>Methods</p> <p>Breast cancer patients since 1998 who fulfilled the following criteria were selected from the departmental database and the case-notes were retrospectively reviewed: (1) estrogen receptor positive, operable primary breast cancer in elderly (age > 70 years), locally advanced or metastatic breast cancer; (2) disease deemed suitable for treatment by hormonal manipulation; (3) disease assessable by UICC criteria; (4) received "withdrawal" from a prior endocrine agent as a form of therapy; (5) on "withdrawal therapy" for ≄ 6 months unless they progressed prior.</p> <p>Results</p> <p>Seventeen patients with median age of 84.3 (53.7-92.5) had "withdrawal therapy" as second to tenth line of treatment following prior endocrine therapy using tamoxifen (n = 10), an aromatase inhibitor (n = 5), megestrol acetate (n = 1) or fulvestrant (n = 1). Ten patients (58.8%) had clinical benefit (CB) (complete response/partial response/stable disease ≄ 6 months) with a median duration of Clinical Benefit (DoCB) of 10+ (7-27) months. Two patients remain on "withdrawal therapy" at the time of analysis.</p> <p>Conclusion</p> <p>"Withdrawal therapy" appears to produce sustained CB in a significant proportion of patients. This applies not only to "withdrawal" from tamoxifen, but also from other categories of endocrine agents. "Withdrawal" from endocrine therapy is, therefore, a viable intercalating option between endocrine agents to minimise resistance and provide additional line of therapy. It should be considered as part of the sequencing of endocrine therapy.</p

    Colouration in amphibians as a reflection of nutritional status : the case of tree frogs in Costa Rica

    Get PDF
    Colouration has been considered a cue for mating success in many species; ornaments in males often are related to carotenoid mobilization towards feathers and/or skin and can signal general health and nutrition status. However, there are several factors that can also link with status, such as physiological blood parameters and body condition, but there is not substantial evidence which supports the existence of these relationships and interactions in anurans. This study evaluated how body score and blood values interact with colouration in free-range Agalychnis callidryas and Agalychnis annae males. We found significant associations between body condition and plasmatic proteins and haematocrit, as well as between body condition and colour values from the chromaticity diagram. We also demonstrated that there is a significant relation between the glucose and plasmatic protein values that were reflected in the ventral colours of the animals, and haematocrit inversely affected most of those colour values. Significant differences were found between species as well as between populations of A. callidryas, suggesting that despite colour variation, there are also biochemical differences within animals from the same species located in different regions. These data provide information on underlying factors for colouration of male tree frogs in nature, provide insights about the dynamics of several nutrients in the amphibian model and how this could affect the reproductive output of the animals

    Search for Gravitational Waves from Primordial Black Hole Binary Coalescences in the Galactic Halo

    Get PDF
    We use data from the second science run of the LIGO gravitational-wave detectors to search for the gravitational waves from primordial black hole (PBH) binary coalescence with component masses in the range 0.2--1.0M⊙1.0 M_\odot. The analysis requires a signal to be found in the data from both LIGO observatories, according to a set of coincidence criteria. No inspiral signals were found. Assuming a spherical halo with core radius 5 kpc extending to 50 kpc containing non-spinning black holes with masses in the range 0.2--1.0M⊙1.0 M_\odot, we place an observational upper limit on the rate of PBH coalescence of 63 per year per Milky Way halo (MWH) with 90% confidence.Comment: 7 pages, 4 figures, to be submitted to Phys. Rev.
    • 

    corecore