138 research outputs found

    Electrospun amplified fiber optics

    Full text link
    A lot of research is focused on all-optical signal processing, aiming to obtain effective alternatives to existing data transmission platforms. Amplification of light in fiber optics, such as in Erbium-doped fiber amplifiers, is especially important for an efficient signal transmission. However, the complex fabrication methods, involving high-temperature processes performed in highly pure environment, slow down the fabrication and make amplified components expensive with respect to an ideal, high-throughput and room temperature production. Here, we report on near infrared polymer fiber amplifiers, working over a band of about 20 nm. The fibers are cheap, spun with a process entirely carried out at room temperature, and show amplified spontaneous emission with good gain coefficients as well as low optical losses (a few cm^-1). The amplification process is favoured by the high fiber quality and low self-absorption. The found performance metrics promise to be suitable for short-distance operation, and the large variety of commercially-available doping dyes might allow for effective multi-wavelength operation by electrospun amplified fiber optics.Comment: 27 pages, 8 figure

    ALBIRA: A small animal PET/SPECT/CT imaging system

    Full text link
    Purpose: The authors have developed a trimodal PET/SPECT/CT scanner for small animal imaging. The gamma ray subsystems are based on monolithic crystals coupled to multianode photomultiplier tubes (MA-PMTs), while computed tomography (CT) comprises a commercially available microfocus x-ray tube and a CsI scintillator 2D pixelated flat panel x-ray detector. In this study the authors will report on the design and performance evaluation of the multimodal system. Methods: X-ray transmission measurements are performed based on cone-beam geometry. Individual projections were acquired by rotating the x-ray tube and the 2D flat panel detector, thus making possible a transaxial field of view (FOV) of roughly 80 mm in diameter and an axial FOV of 65 mm for the CT system. The single photon emission computed tomography (SPECT) component has a dual head detector geometry mounted on a rotating gantry. The distance between the SPECT module detectors can be varied in order to optimize specific user requirements, including variable FOV. The positron emission tomography (PET) system is made up of eight compact modules forming an octagon with an axial FOV of 40 mm and a transaxial FOV of 80 mm in diameter. The main CT image quality parameters (spatial resolution and uniformity) have been determined. In the case of the SPECT, the tomographic spatial resolution and system sensitivity have been evaluated with a99mTc solution using single-pinhole and multi-pinhole collimators. PET and SPECT images were reconstructed using three-dimensional (3D) maximum likelihood and ordered subset expectation maximization (MLEM and OSEM) algorithms developed by the authors, whereas the CT images were obtained using a 3D based FBP algorithm. Results: CT spatial resolution was 85μm while a uniformity of 2.7% was obtained for a water filled phantom at 45 kV. The SPECT spatial resolution was better than 0.8 mm measured with a Derenzo-like phantom for a FOV of 20 mm using a 1-mm pinhole aperture collimator. The full width at half-maximum PET radial spatial resolution at the center of the field of view was 1.55 mm. The SPECT system sensitivity for a FOV of 20 mm and 15% energy window was 700 cps/MBq (7.8 × 10−2%) using a multi-pinhole equipped with five apertures 1 mm in diameter, whereas the PET absolute sensitivity was 2% for a 350–650 keV energy window and a 5 ns timing window. Several animal images are also presented. Conclusions: The new small animal PET/SPECT/CT proposed here exhibits high performance, producing high-quality images suitable for studies with small animals. Monolithic design for PET and SPECT scintillator crystals reduces cost and complexity without significant performance degradation.This study was supported by the Spanish Plan Nacional de Investigacion Cientifica, Desarrollo e Innovacion Tecnologica (I+D+I) under Grant No. FIS2010-21216-CO2-01 and Valencian Local Government under Grant PROMETEO 2008/114. The authors also thank Brennan Holt for checking and correcting the text.Sánchez Martínez, F.; Orero Palomares, A.; Soriano Asensi, A.; Correcher Salvador, C.; Conde Castellanos, PE.; González Martínez, AJ.; Hernández Hernández, L.... (2013). ALBIRA: A small animal PET/SPECT/CT imaging system. Medical Physics. 40(5):5190601-5190611. https://doi.org/10.1118/1.4800798S5190601519061140

    Optical Imaging of Bacterial Infections

    Get PDF
    The rise in multidrug resistant (MDR) bacteria has become a global crisis. Rapid and accurate diagnosis of infection will facilitate antibiotic stewardship and preserve our ability to treat and cure patients from bacterial infection. Direct in situ imaging of bacteria offers the prospect of accurately diagnosing disease and monitoring patient outcomes and response to treatment in real-time. There have been many recent advances in the field of optical imaging of infection; namely in specific probe and fluorophore design. This combined with the advances in imaging device technology render direct optical imaging of infection a feasible approach for accurate diagnosis in the clinic. Despite this, there are currently no licensed molecular probes for clinical optical imaging of infection. Here we report some of the most promising and interesting probes and approaches under development for this purpose, which have been evaluated in in vivo models within the laboratory setting

    A rapid, reproducible, noninvasive predictor of liver graft survival

    Full text link
    BACKGROUND: Clinical and laboratory criteria are not reliable predictors of deceased donor liver graft quality. Intraoperative assessment of experienced surgeons is the gold standard. Standardizing and quantifying this assessment is especially needed now that regional sharing is the rule. We prospectively evaluated a novel, simple, rapid, noninvasive, quantitative measure of liver function performed before graft procurement. MATERIALS AND METHODS: Using a portable, finger-probe–based device, indocyanine green plasma disappearance rates (ICG-PDR) were measured in adult brain-dead donors in the local donor service area before organ procurement. Results were compared with graft function and outcomes. Both donor and recipient teams were blinded to ICG-PDR measurements. RESULTS: Measurements were performed on 53 consecutive donors. Eleven liver grafts were declined by all centers because of quality; the other 42 grafts were transplanted. Logistic regression analysis showed ICG-PDR to be the only donor variable to be significantly associated with 7-d graft survival. Donor risk index, donor age, and transaminase levels at peak or procurement were not significantly associated with 7-d graft survival. CONCLUSIONS: We report the successful use of a portable quantitative means of measuring liver function and its association with graft survival. These data warrant further exploration in a variety of settings to evaluate acceptable values for donated liver grafts
    corecore