138 research outputs found
Electrospun amplified fiber optics
A lot of research is focused on all-optical signal processing, aiming to
obtain effective alternatives to existing data transmission platforms.
Amplification of light in fiber optics, such as in Erbium-doped fiber
amplifiers, is especially important for an efficient signal transmission.
However, the complex fabrication methods, involving high-temperature processes
performed in highly pure environment, slow down the fabrication and make
amplified components expensive with respect to an ideal, high-throughput and
room temperature production. Here, we report on near infrared polymer fiber
amplifiers, working over a band of about 20 nm. The fibers are cheap, spun with
a process entirely carried out at room temperature, and show amplified
spontaneous emission with good gain coefficients as well as low optical losses
(a few cm^-1). The amplification process is favoured by the high fiber quality
and low self-absorption. The found performance metrics promise to be suitable
for short-distance operation, and the large variety of commercially-available
doping dyes might allow for effective multi-wavelength operation by electrospun
amplified fiber optics.Comment: 27 pages, 8 figure
ALBIRA: A small animal PET/SPECT/CT imaging system
Purpose:
The authors have developed a trimodal PET/SPECT/CT scanner for small animal imaging. The gamma ray subsystems are based on monolithic crystals coupled to multianode photomultiplier tubes (MA-PMTs), while computed tomography (CT) comprises a commercially available microfocus x-ray tube and a CsI scintillator 2D pixelated flat panel x-ray detector. In this study the authors will report on the design and performance evaluation of the multimodal system.
Methods:
X-ray transmission measurements are performed based on cone-beam geometry. Individual projections were acquired by rotating the x-ray tube and the 2D flat panel detector, thus making possible a transaxial field of view (FOV) of roughly 80 mm in diameter and an axial FOV of 65 mm for the CT system. The single photon emission computed tomography (SPECT) component has a dual head detector geometry mounted on a rotating gantry. The distance between the SPECT module detectors can be varied in order to optimize specific user requirements, including variable FOV. The positron emission tomography (PET) system is made up of eight compact modules forming an octagon with an axial FOV of 40 mm and a transaxial FOV of 80 mm in diameter. The main CT image quality parameters (spatial resolution and uniformity) have been determined. In the case of the SPECT, the tomographic spatial resolution and system sensitivity have been evaluated with a99mTc solution using single-pinhole and multi-pinhole collimators. PET and SPECT images were reconstructed using three-dimensional (3D) maximum likelihood and ordered subset expectation maximization (MLEM and OSEM) algorithms developed by the authors, whereas the CT images were obtained using a 3D based FBP algorithm.
Results:
CT spatial resolution was 85μm while a uniformity of 2.7% was obtained for a water filled phantom at 45 kV. The SPECT spatial resolution was better than 0.8 mm measured with a Derenzo-like phantom for a FOV of 20 mm using a 1-mm pinhole aperture collimator. The full width at half-maximum PET radial spatial resolution at the center of the field of view was 1.55 mm. The SPECT system sensitivity for a FOV of 20 mm and 15% energy window was 700 cps/MBq (7.8 × 10−2%) using a multi-pinhole equipped with five apertures 1 mm in diameter, whereas the PET absolute sensitivity was 2% for a 350–650 keV energy window and a 5 ns timing window. Several animal images are also presented.
Conclusions:
The new small animal PET/SPECT/CT proposed here exhibits high performance, producing high-quality images suitable for studies with small animals. Monolithic design for PET and SPECT scintillator crystals reduces cost and complexity without significant performance degradation.This study was supported by the Spanish Plan Nacional de Investigacion Cientifica, Desarrollo e Innovacion Tecnologica (I+D+I) under Grant No. FIS2010-21216-CO2-01 and Valencian Local Government under Grant PROMETEO 2008/114. The authors also thank Brennan Holt for checking and correcting the text.Sánchez Martínez, F.; Orero Palomares, A.; Soriano Asensi, A.; Correcher Salvador, C.; Conde Castellanos, PE.; González Martínez, AJ.; Hernández Hernández, L.... (2013). ALBIRA: A small animal PET/SPECT/CT imaging system. Medical Physics. 40(5):5190601-5190611. https://doi.org/10.1118/1.4800798S5190601519061140
Optical Imaging of Bacterial Infections
The rise in multidrug resistant (MDR) bacteria has become a global crisis. Rapid and accurate diagnosis of infection will facilitate antibiotic stewardship and preserve our ability to treat and cure patients from bacterial infection. Direct in situ imaging of bacteria offers the prospect of accurately diagnosing disease and monitoring patient outcomes and response to treatment in real-time. There have been many recent advances in the field of optical imaging of infection; namely in specific probe and fluorophore design. This combined with the advances in imaging device technology render direct optical imaging of infection a feasible approach for accurate diagnosis in the clinic. Despite this, there are currently no licensed molecular probes for clinical optical imaging of infection. Here we report some of the most promising and interesting probes and approaches under development for this purpose, which have been evaluated in in vivo models within the laboratory setting
In Vivo Fluorescence Imaging of Bacteriogenic Cyanide in the Lungs of Live Mice Infected with Cystic Fibrosis Pathogens
10.1371/journal.pone.0021387PLoS ONE67
A rapid, reproducible, noninvasive predictor of liver graft survival
BACKGROUND: Clinical and laboratory criteria are not reliable predictors of deceased donor liver graft quality. Intraoperative assessment of experienced surgeons is the gold standard. Standardizing and quantifying this assessment is especially needed now that regional sharing is the rule. We prospectively evaluated a novel, simple, rapid, noninvasive, quantitative measure of liver function performed before graft procurement. MATERIALS AND METHODS: Using a portable, finger-probe–based device, indocyanine green plasma disappearance rates (ICG-PDR) were measured in adult brain-dead donors in the local donor service area before organ procurement. Results were compared with graft function and outcomes. Both donor and recipient teams were blinded to ICG-PDR measurements. RESULTS: Measurements were performed on 53 consecutive donors. Eleven liver grafts were declined by all centers because of quality; the other 42 grafts were transplanted. Logistic regression analysis showed ICG-PDR to be the only donor variable to be significantly associated with 7-d graft survival. Donor risk index, donor age, and transaminase levels at peak or procurement were not significantly associated with 7-d graft survival. CONCLUSIONS: We report the successful use of a portable quantitative means of measuring liver function and its association with graft survival. These data warrant further exploration in a variety of settings to evaluate acceptable values for donated liver grafts
Relationship between the prevalence of antibodies to arbovirus and hepatitis B virus in the Vale do Ribeira region, Brazil
Relationship between the prevalence of antibodies to hepatitis B core antigen and arbovirus in fishermen from the Ribeira Valley, Brazil
- …