182 research outputs found

    Principles of wildlife conservation-testing distance delivery methodologies

    Get PDF
    In conjunction with faculty at Oregon State University, we developed a distance education course in two phases. During Phase I, conducted Spring of 1996, we used Oregon ED-NET (a simulcast satellite education system) to reach 143 students at 14 sites in Oregon. In the second phase, we offered the course nation-wide in a video format Spring term 1997 and enrolled 92 students at 13 sites. We will offer the video course again during Winter term 1998 following an expanded marketing plan. Our objectives in this paper are to present (1) course design and production information; (2) our experiences with satellite and video teaching; and (3) present information regarding student perceptions and satisfaction with the two distance delivery methods. In Phase I we used notebooks, computer discussion groups, two-way audio, and toll-free phone access to assist students in comprehending the materials. Lectures used computer-graphic screen shows, slides, and locally produced video segments. Based on regular evaluations assessing student learning and satisfaction, we redesigned and professionally produced the course for video distribution in Phase II. Evaluations indicate a high level of satisfaction with the course, but student interaction was minimal. We discuss pros and cons for offering similar courses using these technologies, and present future plans for course enhancement

    Shape and blocking effects on odd-even mass differences and rotational motion of nuclei

    Get PDF
    Nuclear shapes and odd-nucleon blockings strongly influence the odd-even differences of nuclear masses. When such effects are taken into account, the determination of the pairing strength is modified resulting in larger pair gaps. The modified pairing strength leads to an improved self-consistent description of moments of inertia and backbending frequencies, with no additional parameters.Comment: 7 pages, 3 figures, subm to PR

    Prospective Evaluation of Thoracic Ultrasound in the Detection of Pneumothorax

    Get PDF
    Introduction: Pneumothorax (PTX) occurs commonly in trauma patients and is confirmed by examination and radiography. Thoracic ultrasound (VIS) has been suggested as an alternative method for rapidly diagnosing PTX when X-ray is unavailable as in rural, military, or space flight settings; however, its accuracy and specificity are not known. Methods: We evaluated the accuracy of thoracic U/S detection of PTX compared to radiography in stable, emergency patients with a high suspicion of PTX at a Level-l trauma center over a 6-month period. Following University and NASA Institutional Review Board approval, informed consent was obtained from patients with penetrating or blunt chest trauma, or with a history consistent with PTX. Whenever possible, the presence or absence of the " lung sliding" sign or the "comet tail" artifact were determined by U/S in both hemithoraces by residents instructed in thoracic U/S before standard radiologic verification of PTX. Results were recorded on data sheets for comparison to standard radiography. Results: Thoracic VIS had a 94% sensitivity; two PTX could not be reliably diagnosed due to subcutaneous air; the true negative rate was 100%. In one patient, the VIS exam was positive while X ray did not confirm PTX; a follow-up film 1 hour later demonstrated a small PTX. The average time for bilateral thoracic VIS examination was 2 to 3 minutes. Conclusions: Thoracic ultrasound reliably diagnoses pneumothorax. Presence of the "lung sliding" sign conclusively excludes pneumothorax. Expansion of the FAST examination to include the thorax should be investigated

    Second Backbend in the Mass A ~ 180 Region

    Full text link
    Within the framework of selfconsistent cranked Hartree-Fock- Bogoliubov theory(one-dimensional) we predict second backbend in the yrast line of Os-182 at I≈40I \approx 40 , which is even sharper than the first one observed experimentally at I≈14I \approx 14 . Around such a high spin the structure becomes multi-quasiparticle type, but the main source of this strong discontinuity is a sudden large alignment of i_13/2 proton orbitals along the rotation axis followed soon by the alignment of j_15/2 neutron orbitals. This leads to drastic structural changes at such high spins. When experimentally confirmed, this will be observed for the first time in this mass region, and will be at the highest spin so far.Comment: 13 pages, 4 ps figure

    Widespread occurrence of non-canonical transcription termination by human RNA polymerase III

    Get PDF
    Human RNA polymerase (Pol) III-transcribed genes are thought to share a simple termination signal constituted by four or more consecutive thymidine residues in the coding DNA strand, just downstream of the RNA 3â€Č-end sequence. We found that a large set of human tRNA genes (tDNAs) do not display any T≄4 stretch within 50 bp of 3â€Č-flanking region. In vitro analysis of tDNAs with a distanced T≄4 revealed the existence of non-canonical terminators resembling degenerate T≄5 elements, which ensure significant termination but at the same time allow for the production of Pol III read-through pre-tRNAs with unusually long 3â€Č trailers. A panel of such non-canonical signals was found to direct transcription termination of unusual Pol III-synthesized viral pre-miRNA transcripts in gammaherpesvirus 68-infected cells. Genome-wide location analysis revealed that human Pol III tends to trespass into the 3â€Č-flanking regions of tDNAs, as expected from extensive terminator read-through. The widespread occurrence of partial termination suggests that the Pol III primary transcriptome in mammals is unexpectedly enriched in 3â€Č-trailer sequences with the potential to contribute novel functional ncRNA

    A toolkit for optimizing fish passage barrier mitigation actions

    Get PDF
    1. The presence of dams, stream–road crossings and other infrastructure often compromises the connectivity of rivers, leading to reduced fish abundance and diversity. The assessment and mitigation of river barriers is critical to the success of restoration efforts aimed at restoring river integrity. 2. In this study, we present a combined modelling approach involving statistical regression methods and mixed integer linear programming to maximize resident fish species richness within a catchment through targeted barrier mitigation. Compared to existing approaches, our proposed method provides enhanced biological realism while avoiding the use of complex and computationally intensive population/ecosystem models. 3. To estimate barrier passability quickly and at low cost, we further outline a rapid barrier assessment methodology. The methodology is used to characterize potential passage barriers for various fish species common to the UK but can be readily adapted to different planning areas and other species of interest. 4. We demonstrate the applicability of our barrier assessment and prioritization approach based on a case study of the River Wey, located in south-east England. We find that significant increases in species richness can be achieved for modest investment in barrier mitigation. In particular, dams and weirs with low passability located on mid- to high-order streams are identified as top priorities for mitigation. 5. Synthesis and applications. Our study shows the benefits of combining a coarse resolution barrier assessment methodology with state-of-the-art optimization modelling to cost-effectively plan fish passage barrier mitigation actions. The modelling approach can help inform on-the-ground river restoration decision-making by providing a recommended course of action that best allocates limited resources in order to restore longitudinal connectivity and maximize ecological gains

    Advanced Ultrasonic Diagnosis of Extremity Trauma: The Faster Exam

    Get PDF
    Ultrasound is of prO)len accuracy in abdominal and thoracic trauma and may be useful to diagnose extremity injury in situations where radiography is not available such as military and space applications. We prospectively evaluated the utility of extremity , ultrasound performed by trained, non-physician personnel in patients with extremity trauma, to simulate remote aerospace or military applications . Methods: Patients with extremity trauma were identified by history, physical examination, and radiographic studies. Ultrasound examination was performed bilaterally by nonphysician personnel with a portable ultrasound device using a 10-5 MHz linear probe, Images were video-recorded for later analysis against radiography by Fisher's exact test. The average time of examination was 4 minutes. Ultrasound accurately diagnosed extremity, injury in 94% of patients with no false positive exams; accuracy was greater in mid-shaft locations and least in the metacarpa/metatarsals. Soft tissue/tendon injury was readily visualized . Extremity ultrasound can be performed quickly and accurately by nonphysician personnel with excellent accuracy. Blinded verification of the utility of ultrasound in patients with extremity injury should be done to determine if Extremity and Respiratory evaluation should be added to the FAST examination (the FASTER exam) and verify the technique in remote locations such as military and aerospace applications

    Solution of the Skyrme-Hartree-Fock-Bogolyubov equations in the Cartesian deformed harmonic-oscillator basis. (VII) HFODD (v2.49t): a new version of the program

    Full text link
    We describe the new version (v2.49t) of the code HFODD which solves the nuclear Skyrme Hartree-Fock (HF) or Skyrme Hartree-Fock-Bogolyubov (HFB) problem by using the Cartesian deformed harmonic-oscillator basis. In the new version, we have implemented the following physics features: (i) the isospin mixing and projection, (ii) the finite temperature formalism for the HFB and HF+BCS methods, (iii) the Lipkin translational energy correction method, (iv) the calculation of the shell correction. A number of specific numerical methods have also been implemented in order to deal with large-scale multi-constraint calculations and hardware limitations: (i) the two-basis method for the HFB method, (ii) the Augmented Lagrangian Method (ALM) for multi-constraint calculations, (iii) the linear constraint method based on the approximation of the RPA matrix for multi-constraint calculations, (iv) an interface with the axial and parity-conserving Skyrme-HFB code HFBTHO, (v) the mixing of the HF or HFB matrix elements instead of the HF fields. Special care has been paid to using the code on massively parallel leadership class computers. For this purpose, the following features are now available with this version: (i) the Message Passing Interface (MPI) framework, (ii) scalable input data routines, (iii) multi-threading via OpenMP pragmas, (iv) parallel diagonalization of the HFB matrix in the simplex breaking case using the ScaLAPACK library. Finally, several little significant errors of the previous published version were corrected.Comment: Accepted for publication to Computer Physics Communications. Program files re-submitted to Comp. Phys. Comm. Program Library after correction of several minor bug

    Rapid Diagnosis of an Ulnar Fracture with Portable Hand-Held Ultrasound

    Get PDF
    Orthopedic fractures are a common injury in operational activities, injuries that often occur in isolated or hostile environments. Clinical ultrasound devices have become more user friendly and lighter allowing them to be easily transported with forward medical teams. The bone-soft tissue interface has a very large acoustic impedance, with a high reflectance that can be used to visualize breaks in contour including fractures. Herein reported is a case of an ulnar fracture that was quickly visualized in the early phase of a multi-system trauma resuscitation with a hand-held ultrasound device. The implications for operational medicine are discussed
    • 

    corecore